Chulkyun Ahn

Mr. Chulkyun Ahn

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in Korean Journal of Radiology
Verified
Journal Article
Open access
PDF file
JHJung hee Hong
Jung hee Hong
EPEun-Ah Park
Eun-Ah Park
WLWhal Lee
Whal Lee
CAChulkyun Ahn
Chulkyun Ahn
JKJong Hyo Kim
Jong Hyo Kim
Hong JH, et al. Korean J Radiol. 2020 Jul;21:e105. https://doi.org/10.3348/kjr.2020.0020

1 January 2021 in Korean Journal of Radiology
Verified
Journal Article
Open access
PDF file
HYHyunjung Yeoh
Hyunjung Yeoh
SHSung Hwan Hong
Sung Hwan Hong
CAChulkyun Ahn
Chulkyun Ahn
JCJa-Young Choi
Ja-Young Choi
HCHee-Dong Chae
Hee-Dong Chae
JKJong Hyo Kim
Jong Hyo Kim
Yeoh H, et al. Korean J Radiol. 2021 Nov;22(11):1850-1857. https://doi.org/10.3348/kjr.2021.0140

3 March 2017
Verified
Conference Paper
Closed access
PDF file
CAChulkyun Ahn
Chulkyun Ahn
CHChangyong Heo
Changyong Heo
HJHeongmin Jin
Heongmin Jin
JKJong Hyo Kim
Jong Hyo Kim

20 July 2022 in PLOS ONE
Verified
Journal Article
Open access
PDF file
MCMinsoo Chun
Minsoo Chun
JCJin Hwa Choi
Jin Hwa Choi
SKSihwan Kim
Sihwan Kim
CAChulkyun Ahn
Chulkyun Ahn
JKJong Hyo Kim
Jong Hyo Kim
While the recent advancements of computed tomography (CT) technology have contributed in reducing radiation dose and image noise, an objective evaluation of image quality in patient scans has not yet been established. In this study, we present a patient-specific CT image quality evaluation method that includes fully automated measurements of noise level, structure sharpness, and alteration of structure. This study used the CT images of 120 patients from four different CT scanners reconstructed with three types of algorithm: filtered back projection (FBP), vendor-specific iterative reconstruction (IR), and a vendor-agnostic deep learning model (DLM, ClariCT.AI, ClariPi Inc.). The structure coherence feature (SCF) was used to divide an image into the homogeneous (RH) and structure edge (RS) regions, which in turn were used to localize the regions of interests (ROIs) for subsequent analysis of image quality indices. The noise level was calculated by averaging the standard deviations from five randomly selected ROIs on RH, and the mean SCFs on RS was used to estimate the structure sharpness. The structure alteration was defined by the standard deviation ratio between RS and RH on the subtraction image between FBP and IR or DLM, in which lower structure alterations indicate successful noise reduction without degradation of structure details. The estimated structure sharpness showed a high correlation of 0.793 with manually measured edge slopes. Compared to FBP, IR and DLM showed 34.38% and 51.30% noise reduction, 2.87% and 0.59% lower structure sharpness, and 2.20% and -12.03% structure alteration, respectively, on an average. DLM showed statistically superior performance to IR in all three image quality metrics. This study is expected to contribute to enhance the CT protocol optimization process by allowing a high throughput and quantitative image quality evaluation during the introduction or adjustment of lower-dose CT protocol into routine practice.

14 September 2023 in Abdominal Radiology
Verified
Journal Article
Closed access
PDF file
TLTaehee Lee
Taehee Lee
JYJeong Hee Yoon
Jeong Hee Yoon
JPJin Young Park
Jin Young Park
JLJihyuk Lee
Jihyuk Lee
JCJae Won Choi
Jae Won Choi
SLSang Min Lee
Sang Min Lee

9 March 2018
Verified
Conference Paper
Closed access
PDF file
CAChulkyun Ahn
Chulkyun Ahn
JKJong Hyo Kim
Jong Hyo Kim
ZYZepa Yang
Zepa Yang
CHChangyong Heo
Changyong Heo
HJHyeongmin Jin
Hyeongmin Jin
BPByungjun Park
Byungjun Park
Effective elimination of unique CT noise pattern while preserving adequate image quality is crucial in reducing radiation dose to ultra-low-dose level in CT imaging practice. In this study, we present a novel Deep Learning-enable Iterative Reconstruction (Deep IR) approach for CT denoising which incorporate a synthetic sinogram-based noise simulation technique for training of Convolutional Neural Network (CNN). Regular dose CT images from 25 patients were used from Seoul National University Hospital. The CT scans were performed at 140 kVp, 100 mAs, and reconstructed with standard FBP technique using B60f kernel. Among them, 20 patients were randomly selected as a training set and the rest 5 patients were used for a test set. We applied a re-projection technique to create a synthetic sinogram from the DICOM CT image, and then a simulated noise sinogram was generated to match the noise level of 10mAs according to Poisson statistic and the system noise model of the given scanner (Somatom Sensation 16, Siemens). We added the simulated noise sinogram to the re-projected synthetic sinogram to generate a simulated sinogram of ultra-low dose scan. We also created the simulated ultra-low-dose CT image by applying FBP reconstruction of the simulated noise sinogram with B60f kernel. A CNN model was created using a TensorFlow framework to have 10 consecutive convolution layer and activation layer. The CNN was trained to learn the noise in sinogram domain: the simulated noisy sinogram of ultra-low dose scan was fed into its input nodes with the output node being fed by the simulated noise sinogram. At test phase, the noise sinogram from the CNN output was reconstructed with using B60f kernel to create a noise CT image, which in turn was subtracted from the simulated ultra-low-dose CT image to produce a Deep IR CT image. The performance was evaluated quantitatively in terms of structural similarity (SSIM) index, peak signal-to-noise ratio (PSNR) and noise level measurement and qualitatively in CT image by comparing the noise pattern and image quality. Compared to low-dose image, denoising image of the SSIM and the PSNR were improved from 0.75 to 0.80, 28.61db to 32.16 respectively. The noise level of denoising image was reduced to an average of 56 % of that of low-dose image. The noise pattern in reconstructed noise CT was indistinguishable from that of real CT images, and the image quality of Deep IR CT image was overall much higher than that of simulated ultra-low-dose CT.