Jong Hyo Kim

Prof. Dr. Jong Hyo Kim

orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in Korean Journal of Radiology
Verified
Journal Article
Open access
PDF file
JHJung hee Hong
Jung hee Hong
EPEun-Ah Park
Eun-Ah Park
WLWhal Lee
Whal Lee
CAChulkyun Ahn
Chulkyun Ahn
JKJong Hyo Kim
Jong Hyo Kim
Hong JH, et al. Korean J Radiol. 2020 Jul;21:e105. https://doi.org/10.3348/kjr.2020.0020

1 January 2021 in Korean Journal of Radiology
Verified
Journal Article
Open access
PDF file
HYHyunjung Yeoh
Hyunjung Yeoh
SHSung Hwan Hong
Sung Hwan Hong
CAChulkyun Ahn
Chulkyun Ahn
JCJa-Young Choi
Ja-Young Choi
HCHee-Dong Chae
Hee-Dong Chae
JKJong Hyo Kim
Jong Hyo Kim
Yeoh H, et al. Korean J Radiol. 2021 Nov;22(11):1850-1857. https://doi.org/10.3348/kjr.2021.0140

29 June 2020 in European Radiology
Verified
Journal Article
Closed access
PDF file
SBSo Hyeon Bak
So Hyeon Bak
JKJong Hyo Kim
Jong Hyo Kim
HJHyeongmin Jin
Hyeongmin Jin
SKSung Ok Kwon
Sung Ok Kwon
BKBom Kim
Bom Kim
WKWoo-Jin Kim
Woo-Jin Kim

1 January 2017 in Korean Journal of Radiology
Verified
Journal Article
Open access
PDF file
MLMyungeun Lee
Myungeun Lee
BWBoyeong Woo
Boyeong Woo
MKMichael D. Kuo
Michael D. Kuo
NJNeema Jamshidi
Neema Jamshidi
JKJong Hyo Kim
Jong Hyo Kim
Lee M, et al. Korean J Radiol. 2017 May-Jun;18(3):498-509. https://doi.org/10.3348/kjr.2017.18.3.498

1 January 2019 in Korean Journal of Radiology
Verified
Journal Article
Open access
WLWoo Hyeon Lim
Woo Hyeon Lim
YCYoung Hun Choi
Young Hun Choi
JPJi Eun Park
Ji Eun Park
YCYeon Jin Cho
Yeon Jin Cho
LSLee Seunghyun
Lee Seunghyun
JKJong Hyo Kim
Jong Hyo Kim
To compare image qualities between vendor-neutral and vendor-specific hybrid iterative reconstruction (IR) techniques for abdominopelvic computed tomography (CT) in young patients. In phantom study, we used an anthropomorphic pediatric phantom, age-equivalent to 5-year-old, and reconstructed CT data using traditional filtered back projection (FBP), vendor-specific and vendor-neutral IR techniques (ClariCT; ClariPI) in various radiation doses. Noise, low-contrast detectability and subjective spatial resolution were compared between FBP, vendor-specific (i.e., iDose1 to 5; Philips Healthcare), and vendor-neutral (i.e., ClariCT1 to 5) IR techniques in phantom. In 43 patients (median, 14 years; age range 1-19 years), noise, contrast-to-noise ratio (CNR), and qualitative image quality scores of abdominopelvic CT were compared between FBP, iDose level 4 (iDose4), and ClariCT level 2 (ClariCT2), which showed most similar image quality to clinically used vendor-specific IR images (i.e., iDose4) in phantom study. Noise, CNR, and qualitative imaging scores were compared using one-way repeated measure analysis of variance. In phantom study, ClariCT2 showed noise level similar to iDose4 (14.68-7.66 Hounsfield unit [HU] vs. 14.78-6.99 HU at CT dose index volume range of 0.8-3.8 mGy). Subjective low-contrast detectability and spatial resolution were similar between ClariCT2 and iDose4. In clinical study, ClariCT2 was equivalent to iDose4 for noise (14.26-17.33 vs. 16.01-18.90) and CNR (3.55-5.24 vs. 3.20-4.60) (p > 0.05). For qualitative imaging scores, the overall image quality ([reader 1, reader 2]; 2.74 vs. 2.07, 3.02 vs. 2.28) and noise (2.88 vs. 2.23, 2.93 vs. 2.33) of ClariCT2 were superior to those of FBP (p < 0.05), and not different from those of iDose4 (2.74 vs. 2.72, 3.02 vs. 2.98; 2.88 vs. 2.77, 2.93 vs. 2.86) (p > 0.05). Vendor-neutral IR technique shows image quality similar to that of clinically used vendor-specific hybrid IR technique for abdominopelvic CT in young patients.

20 July 2022 in PLOS ONE
Verified
Journal Article
Open access
PDF file
MCMinsoo Chun
Minsoo Chun
JCJin Hwa Choi
Jin Hwa Choi
SKSihwan Kim
Sihwan Kim
CAChulkyun Ahn
Chulkyun Ahn
JKJong Hyo Kim
Jong Hyo Kim
While the recent advancements of computed tomography (CT) technology have contributed in reducing radiation dose and image noise, an objective evaluation of image quality in patient scans has not yet been established. In this study, we present a patient-specific CT image quality evaluation method that includes fully automated measurements of noise level, structure sharpness, and alteration of structure. This study used the CT images of 120 patients from four different CT scanners reconstructed with three types of algorithm: filtered back projection (FBP), vendor-specific iterative reconstruction (IR), and a vendor-agnostic deep learning model (DLM, ClariCT.AI, ClariPi Inc.). The structure coherence feature (SCF) was used to divide an image into the homogeneous (RH) and structure edge (RS) regions, which in turn were used to localize the regions of interests (ROIs) for subsequent analysis of image quality indices. The noise level was calculated by averaging the standard deviations from five randomly selected ROIs on RH, and the mean SCFs on RS was used to estimate the structure sharpness. The structure alteration was defined by the standard deviation ratio between RS and RH on the subtraction image between FBP and IR or DLM, in which lower structure alterations indicate successful noise reduction without degradation of structure details. The estimated structure sharpness showed a high correlation of 0.793 with manually measured edge slopes. Compared to FBP, IR and DLM showed 34.38% and 51.30% noise reduction, 2.87% and 0.59% lower structure sharpness, and 2.20% and -12.03% structure alteration, respectively, on an average. DLM showed statistically superior performance to IR in all three image quality metrics. This study is expected to contribute to enhance the CT protocol optimization process by allowing a high throughput and quantitative image quality evaluation during the introduction or adjustment of lower-dose CT protocol into routine practice.