Elias Sundström

Mr. Elias Sundström

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 November 2017 in Flow, Turbulence and Combustion
Verified
Journal Article
Open access
PDF file
ESElias Sundström
Elias Sundström
Bernhard SemlitschBernhard Semlitsch
Bernhard Semlitsch
MMMihai Mihaescu
Mihai Mihaescu
Flow instabilities such as Rotating Stall and Surge limit the operating range of centrifugal compressors at low mass-flow rates. Employing compressible Large Eddy Simulations (LES), their generation mechanisms are exposed. Toward low mass-flow rate operating conditions, flow reversal over the blade tips (generated by the back pressure) causes an inflection point of the inlet flow profile. There, a shear-layer induces vortical structures circulating at the compressor inlet. Traces of these flow structures are observed until far downstream in the radial diffuser. The tip leakage flow exhibits angular momentum imparted by the impeller, which deteriorates the incidence angles at the blade tips through an over imposed swirling component to the incoming flow. We show that the impeller is incapable to maintain constant efficiency at surge operating conditions due to the extreme alteration of the incidence angle. This induces unsteady flow momentum transfer downstream, which is reflected as compression wave at the compressor outlet traveling toward the impeller. There, the pressure oscillations govern the tip leakage flow and hence, the incidence angles at the impeller. When these individual self-exited processes occurs in-phase, a surge limit-cycle establishes.

18 June 2015
Verified
Conference Paper
Closed access
ESElias Sundström
Elias Sundström
MMMihai Mihaescu
Mihai Mihaescu

ESElias Sundström
Elias Sundström
MMMihai Mihaescu
Mihai Mihaescu
MGMarco Giachi
Marco Giachi
EBElisabetta Belardini
Elisabetta Belardini
VMVittorio Michelassi
Vittorio Michelassi
Numerical simulations based on the large eddy simulation approach were conducted with the aim to explore vaneless diffuser rotating stall instability in a centrifugal compressor. The effect of the impeller blade passage was included as an inlet boundary condition with sufficiently low flow angle relative to the tangent to provoke the instability and cause circulation in the diffuser core flow. Flow quantities, velocity and pressure, were extracted to accumulate statistics for calculating mean velocity and mean Reynolds stresses in the wall-to-wall direction. The paper focuses on the assessment of the complex response of the system to the velocity perturbations imposed, the resulting pressure gradient and flow curvature effects.

18 October 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
ESElias Sundström
Elias Sundström
MLMarco Laudato
Marco Laudato
Subjects with bicuspid aortic valves (BAV) are at risk of developing valve dysfunction and need regular clinical imaging surveillance. Management of BAV involves manual and time-consuming segmentation of the aorta for assessing left ventricular function, jet velocity, gradient, shear stress, and valve area with aortic valve stenosis. This paper aims to employ machine learning-based (ML) segmentation as a potential for improved BAV assessment and reducing manual bias. The focus is on quantifying the relationship between valve morphology and vortical structures, and analyzing how valve morphology influences the aorta’s susceptibility to shear stress that may lead to valve incompetence. The ML-based segmentation that is employed is trained on whole-body Computed Tomography (CT). Magnetic Resonance Imaging (MRI) is acquired from six subjects, three with tricuspid aortic valves (TAV) and three functionally BAV, with right–left leaflet fusion. These are used for segmentation of the cardiovascular system and delineation of four-dimensional phase-contrast magnetic resonance imaging (4D-PCMRI) for quantification of vortical structures and wall shear stress. The ML-based segmentation model exhibits a high Dice score (0.86) for the heart organ, indicating a robust segmentation. However, the Dice score for the thoracic aorta is comparatively poor (0.72). It is found that wall shear stress is predominantly symmetric in TAVs. BAVs exhibit highly asymmetric wall shear stress, with the region opposite the fused coronary leaflets experiencing elevated tangential wall shear stress. This is due to the higher tangential velocity explained by helical flow, proximally of the sinutubal junction of the ascending aorta. ML-based segmentation not only reduces the runtime of assessing the hemodynamic effectiveness, but also identifies the significance of the tangential wall shear stress in addition to the axial wall shear stress that may lead to the progression of valve incompetence in BAVs, which could guide potential adjustments in surgical interventions.

28 November 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
FKFlorian Kraxberger
Florian Kraxberger
CNChristoph Näger
Christoph Näger
MLMarco Laudato
Marco Laudato
ESElias Sundström
Elias Sundström
SBStefan Becker
Stefan Becker
SSStefan Schoder
Stefan Schoder
Sound generation in human phonation and the underlying fluid–structure–acoustic interaction that describes the sound production mechanism are not fully understood. A previous experimental study, with a silicone made vocal fold model connected to a straight vocal tract pipe of fixed length, showed that vibroacoustic coupling can cause a deviation in the vocal fold vibration frequency. This occurred when the fundamental frequency of the vocal fold motion was close to the lowest acoustic resonance frequency of the pipe. What is not fully understood is how the vibroacoustic coupling is influenced by a varying vocal tract length. Presuming that this effect is a pure coupling of the acoustical effects, a numerical simulation model is established based on the computation of the mechanical-acoustic eigenvalue. With varying pipe lengths, the lowest acoustic resonance frequency was adjusted in the experiments and so in the simulation setup. In doing so, the evolution of the vocal folds’ coupled eigenvalues and eigenmodes is investigated, which confirms the experimental findings. Finally, it was shown that for normal phonation conditions, the mechanical mode is the most efficient vibration pattern whenever the acoustic resonance of the pipe (lowest formant) is far away from the vocal folds’ vibration frequency. Whenever the lowest formant is slightly lower than the mechanical vocal fold eigenfrequency, the coupled vocal fold motion pattern at the formant frequency dominates.

12 October 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
ESElias Sundström
Elias Sundström
MJMichael Jiang
Michael Jiang
HNHani K. Najm
Hani K. Najm
JTJustin Tretter
Justin Tretter
Background: This article presents the use of blood speckle Imaging (BSI) as an echocardiographic approach for the pre- and post-operative evaluation of subaortic membrane resection and aortic valve repair. Method: BSI, employing block-matching algorithms, provided detailed visualization of flow patterns and quantification of parameters from ultrasound data. The 9-year-old patient underwent subaortic membrane resection and peeling extensions of the membrane from under the ventricular-facing surface of all three aortic valve leaflets. Result: Post-operatively, BSI demonstrated improvements in hemodynamic patterns, where quantified changes in flow velocities showed no signs of stenosis and trivial regurgitation. The asymmetric jet with a shear layer and flow reversal on the posterior aspect of the aorta was corrected resulting in reduced wall shear stress on the anterior aspect and reduced oscillatory shear index, which is considered a contributing element in cellular alterations in the structure of the aortic wall. Conclusion: This proof-of-concept study demonstrates the potential of BSI as an emerging echocardiographic approach for evaluating subaortic and aortic valvar repair. BSI enhances the quantitative evaluation of the left ventricular outflow tract of immediate surgical outcomes beyond traditional echocardiographic parameters and aids in post-operative decision-making. However, larger studies are needed to validate these findings and establish standardized protocols for clinical implementation.