José Ginés Hernández Cifre

Dr. José Ginés Hernández Cifre

orcid

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 July 2008 in Colloid and Polymer Science
Verified
Journal Article
Closed access
PDF file
Ramon PamiesRamon Pamies
Ramon Pamies
JCJosé Ginés Hernández Cifre
José Ginés Hernández Cifre
MMMaría del Carmen López Martínez
María del Carmen López Martínez
Jose Garcia De La TorreJose Garcia De La Torre
Jose Garcia De La Torre

1 April 2014 in Journal of Nanoparticle Research
Verified
Journal Article
Closed access
PDF file
Ramon PamiesRamon Pamies
Ramon Pamies
JCJosé Ginés Hernández Cifre
José Ginés Hernández Cifre
VEVanesa Fernández Espín
Vanesa Fernández Espín
MCMaría del Mar Collado-González
María del Mar Collado-González
FBF. Guillermo Díaz Baños
F. Guillermo Díaz Baños
Jose Garcia De La TorreJose Garcia De La Torre
Jose Garcia De La Torre

21 May 2015 in PLOS ONE
Verified
Journal Article
Open access
PDF file
HZHuaying Zhao
Huaying Zhao
RGRodolfo Ghirlando
Rodolfo Ghirlando
CACarlos Alfonso
Carlos Alfonso
FAFumio Arisaka
Fumio Arisaka
IAIlan Attali
Ilan Attali
PSPeter Schuck
Peter Schuck
Analytical ultracentrifugation (AUC) is a first principles based method to determine absolute sedimentation coefficients and buoyant molar masses of macromolecules and their complexes, reporting on their size and shape in free solution. The purpose of this multi-laboratory study was to establish the precision and accuracy of basic data dimensions in AUC and validate previously proposed calibration techniques. Three kits of AUC cell assemblies containing radial and temperature calibration tools and a bovine serum albumin (BSA) reference sample were shared among 67 laboratories, generating 129 comprehensive data sets. These allowed for an assessment of many parameters of instrument performance, including accuracy of the reported scan time after the start of centrifugation, the accuracy of the temperature calibration, and the accuracy of the radial magnification. The range of sedimentation coefficients obtained for BSA monomer in different instruments and using different optical systems was from 3.655 S to 4.949 S, with a mean and standard deviation of (4.304 ± 0.188) S (4.4%). After the combined application of correction factors derived from the external calibration references for elapsed time, scan velocity, temperature, and radial magnification, the range of s-values was reduced 7-fold with a mean of 4.325 S and a 6-fold reduced standard deviation of ± 0.030 S (0.7%). In addition, the large data set provided an opportunity to determine the instrument-to-instrument variation of the absolute radial positions reported in the scan files, the precision of photometric or refractometric signal magnitudes, and the precision of the calculated apparent molar mass of BSA monomer and the fraction of BSA dimers. These results highlight the necessity and effectiveness of independent calibration of basic AUC data dimensions for reliable quantitative studies.

1 August 2003 in Journal of Non-Newtonian Fluid Mechanics
Verified
Journal Article
Closed access
JCJosé Ginés Hernández Cifre
José Ginés Hernández Cifre
TBTh.M.A.O.M Barenbrug
Th.M.A.O.M Barenbrug
JSJay Schieber
Jay Schieber
BBB.H.A.A van Den Brule
B.H.A.A van Den Brule

1 March 1999 in Journal of Rheology
Verified
Journal Article
Closed access
PDF file
JCJosé Ginés Hernández Cifre
José Ginés Hernández Cifre
JTJ. Garcı́a de la Torre
J. Garcı́a de la Torre
The steady-state properties of flexible polymer chains in solutions undergoing elongational flow have been studied using Brownian dynamics simulation. The coil–stretch transition is observed when the elongational rate, ε̇ exceeds a certain critical value ε̇c. In this work, we describe in detail the simulation procedure and how to extract polymer dimensions, solution viscosity, and birefringence from the trajectories. Preliminary simulations involving no hydrodynamic interaction (HI) are used to check the simulation procedures by comparing their results with theoretical predictions for such an (unphysical) case. Afterwards, simulations with fluctuating nonaveraged HI are carried out to provide results comparable with experiments. After simulations with and without intramolecular potential, we arrive at a most important conclusion: the chain length dependence of ε̇c is the same in theta conditions as in good solvent conditions. Combining ε̇c with other solution properties such as the longest relaxation time, the intrinsic viscosity, and the radius of gyration, dimensionless compound quantities can be formulated. From our simulation results, we obtain numerical values for such quantities, which include the HI effect, and which are therefore useful for analyzing experimental data.

16 March 2006 in The Journal of Physical Chemistry B
Verified
Journal Article
Closed access
NBNeda Beheshti
Neda Beheshti
HBHuaitian Bu
Huaitian Bu
KZKaizheng Zhu
Kaizheng Zhu
AKAnna-Lena Kjoniksen
Anna-Lena Kjoniksen
KKKenneth Knudsen
Kenneth Knudsen
BNBo Nyström
Bo Nyström