Cuthbert Nyamupangedengu

Prof. Cuthbert Nyamupangedengu


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 June 2017 in High Voltage
Verified
Journal Article
Open access
PDF file
SKSharif F. Kaaiye
Sharif F. Kaaiye
CNCuthbert Nyamupangedengu
Cuthbert Nyamupangedengu
Currently there are no international standards for evaluating the tracking and erosion resistance of DC polymeric insulation under contaminated conditions. Researchers often modify the existing AC inclined plane test standards such as the IEC‐60587 to accommodate DC voltage conditions but this has been reported to give various inconsistences. This paper presents comprehensive experimental results on inclined plane tests of silicone rubber (SiR) insulation at 3.5 and 4.5 kV AC and positive DC using intravenous (IV) system as the pollutant supply. The leakage currents (LC) were recorded throughout the entire tests. In addition, various physiochemical tests namely, Fourier Transform Infrared analysis, thermo‐gravimetric analysis, scanning electron microscopy and energy dispersive spectroscopy were performed on the aged and unaged samples. Results show that DC LC is bigger (about three times) than that under AC for the same equivalent voltages. Furthermore, DC LC variations are less random and the average magnitudes increase with duration of voltage application compared with AC. The physiochemical analyses show that 3.5 kV rms AC and 3.5 kV DC aged samples have comparable chemical characteristics albeit with electrode corrosion elements detected on the DC aged samples. Under 4.5 kV DC the degradation becomes significantly more severe and unrepeatable. It is therefore concluded that at 0.3 ml/min, pollutant flow rate, 3.5 kV positive DC and 3.5 kV rms AC are comparable as test voltages for inclined plane accelerated ageing of SiR insulation.

29 November 2021 in Energies
Verified
Journal Article
Open access
PDF file
MKMohammed Mahmood Katun
Mohammed Mahmood Katun
RKRudo Kadzutu-Sithole
Rudo Kadzutu-Sithole
NMNosipho Moloto
Nosipho Moloto
CNCuthbert Nyamupangedengu
Cuthbert Nyamupangedengu
CGChandima Gomes
Chandima Gomes
Thermal stress and moisture absorption can cause a synergetic negative impact on kraft paper. Among various approaches for improving the dielectric properties of kraft paper, nanotechnology has had promising results. However, the hydrophilicity of most metal oxide nanoparticles renders nanomodified kraft paper more vulnerable to thermal stress and moisture, thereby inducing degradation. In nanomodified kraft paper research, the use of TiO2 nanoparticles has yielded the most promising results. The major shortfall, however, is the hydrophilicity of TiO2. This work investigated surface modifications of rutile-TiO2 nanoparticles (NPs) for improved hydrophobicity and thermal stability. Rutile-TiO2 NPs is a nontoxic metal oxide that can withstand high temperature and is stable in chemical reactions. Two cases of surfactants were used—alkyl ketene dimer (AKD) and alkenyl succinic anhydride (ASA). The intention was to increase heat resistance and reduce the surface free energy of the rutile-TiO2 NPs. The impacts of the surface modifiers on the rutile-TiO2 NPs were characterised using FT-IR, muffle furnace, analytical weight balance, and TGA. It was discovered that new functional groups were formed on the modified NPs examined through FT-IR spectra. This indicates new chemical bonds, introduced through the surface modification. The unmodified rutile-TiO2 NPs absorbed moisture, increasing their mass by 3.88%, compared with the modified nanoparticles, which released moisture instead. TGA analysis revealed that AKD- and ASA-modified rutile-TiO2 needed higher temperatures than the unmodified rutile-TiO2 to markedly decompose. AKD, however, gave better performance than ASA in that regard. As an example, those modified with 5% AKD sustained a 45% higher temperature than the pure TiO2 nanoparticles. Furthermore, in both cases of the surfactants, the higher the percent of surfactant content was, the more thermally stable the nanoparticles became. This work demonstrates the possibility of fabricating rutile-TiO2 NPs to give improved hydrophobicity and thermal stability for possible dielectric applications such as in kraft paper for power transformer insulation.

1 September 2019 in SAIEE Africa Research Journal
Verified
Journal Article
Closed access
EHE. N. N. Haikali
E. N. N. Haikali
CNCuthbert Nyamupangedengu
Cuthbert Nyamupangedengu

18 January 2021 in Energies
Verified
Journal Article
Open access
PDF file
TVTapiwa Venge
Tapiwa Venge
CNCuthbert Nyamupangedengu
Cuthbert Nyamupangedengu
The supply voltage frequency effect on partial discharge (PD) phenomena has continued to draw research interest. Although most high voltage equipment operates at power frequency (50/60 Hz), testing is often done at different frequencies for various reasons. Despite some agreements and inconsistencies for the research findings of PD activity’s frequency dependence, there has been consensus on the recognition of the discharge mechanism parameters that influence how the supply voltage frequency affects PD activity. These parameters include statistical time lag, discharge area surface conductivity, and the residual charge decay. In this paper, a 3-capacitor model (ABC) is used to simulate how the changes in the discharge mechanism parameters influence PD characteristics as a function of the supply voltage frequency. The findings are that the phase-resolved partial discharge pattern (PRPDP) and PD repetition rate (PDRR) characteristics are more sensitive to variations in the probability of the seed electron availability at higher frequencies of the supply voltage. The opposite trend is observed for the cavity surface resistance. At lower resistance of cavity surface, the PRPDP and PDRR characteristics are more sensitive to changes in the supply voltage frequency than at higher resistances. The paper also confirms that incorporating equivalent resistances in the ABC model makes it more authentic than the model comprising of capacitors only.

24 February 2023 in High Voltage
Verified
Journal Article
Open access
CNCuthbert Nyamupangedengu
Cuthbert Nyamupangedengu
TVTapiwa Venge
Tapiwa Venge
Partial discharges (PD) are the ‘cancer’ of electrical insulation. Insulation design and mitigation of PD‐induced degradation should be based on good knowledge of PD phenomena. In that regard, a significant body of knowledge has been built up from concerted research across the world in past decades and on various aspects of PD phenomena under various conditions. However, the work is far from being complete as new challenges arise. One such challenge is that electric power equipment insulation is becoming more exposed to non‐power frequency voltages. Examples are the proliferation of invertor‐based grid‐tied renewable energy sources and other technologies such as high‐frequency power electronic transformers. Questions that are driving continued research in this regard include the reasons for lack of consensus on the findings on how PD characteristics respond to variations in the voltage frequency. This paper presents results of how residual charge influences PD characteristics' response to voltage frequency changes from 1 to 200 Hz. The study approach is implementing the extended 3‐capacitor PD model in MATLAB ® Simulink ® and validating the findings using the relevant experimental results that are available in literature. The PD type studied is that of an air cavity encapsulated in a polyethylene dielectric. Highlights of the findings are that the extent of the influence of residual charge on PD characteristics depends on the relative magnitude of the residual charge as well as the voltage frequency. The relationships however exhibit non‐monotonous trends. Such results further confirm similar findings and conclusions by other researchers and could be signalling the establishment of a more solid knowledge base for design of insulations that operate at non‐power frequencies.

2 July 2022 in Energies
Verified
Journal Article
Open access
PDF file
CWCarl Wolmarans
Carl Wolmarans
CNCuthbert Nyamupangedengu
Cuthbert Nyamupangedengu
CSCarina Schumann
Carina Schumann
NCNeil Coville
Neil Coville
Marcelo M F SabaMarcelo M F Saba
Marcelo M F Saba
Liquid insulation is used in high voltage equipment such as power transformers as both dielectric medium and coolant. Breakdown in liquid insulation tends to be governed either by streamer initiation under more uniform fields, or by streamer propagation under more non-uniform fields. A model streamer propagation study, which screens the effectiveness of additives based on cyclohexane and mixtures with diethylaniline (DEA) and toluene, is presented in this paper. The effect of additives, at different concentrations, on streamer propagation velocity in cyclohexane under an applied lightning impulse voltage of positive polarity is studied. Cyclohexane (ionisation potential 9.88 eV) was chosen because, being a hydrocarbon, it shares similarities with the constituents of common insulating liquids. Previous studies have also shown how, in general, the addition of additives of lower ionization potential than the bulk liquid can slow down streamer propagation in insulating liquids. A point-plane electrode configuration of 70 mm gap with a 5 μm tip radius is used and subjected to an applied positive polarity impulse of 1.2/50 μs. A high velocity imaging system is also used to capture streamer images to validate a Time-To-Breakdown (TTB) measurement approach used in inferring approximate streamer velocity. The DEA (ionisation potential 6.98 eV) was found to be an effective additive to slow down positive polarity streamers in cyclohexane in the applied voltage range (≈220–280 kV peak) in concentrations above approximately 0.33% (by volume). Toluene (ionisation potential 8.82 eV) was found not to significantly slow down streamers in cyclohexane, even at 10% concentration, for the same voltage range. This is postulated to be due to the fact that toluene does not have a low enough ionisation potential (with respect to that of the cyclohexane) to change the streamer branching characteristics sufficiently during propagation.