The interaction of the [B10H10]2– and [B12H12]2– anions with aliphatic and aromatic nitro compounds (RNO2, where R = Et, n-Pr, i-Pr, tert-Bu, Ph) has been studied under irradiation with visible and UV
New methods of creation of cyclic bridging and terminal exopolyhedral sulfur-containing substituents in the closo-decaborate anion have been suggested. It has been shown that the reaction of...
Polymer nanocomposites filled with carbon nanoparticles (CNPs) are a hot topic in materials science. This article discusses the current research on the use of these materials as interfacial electron transfer films for solid contact potentiometric membrane sensors (SC-PMSs). The results of a comparative study of plasticized poly (vinyl chloride) (pPVC) matrices modified with single-walled carbon nanotubes (SWCNTs), fullerenes-C60, and their hybrid ensemble (SWCNTs-C60) are reported. The morphological characteristics and electrical conductivity of the prepared nanostructured composite films are reported. It was found that the specific electrical conductivity of the pPVC/SWCNTs-C60 polymer film was higher than that of pPVC filled with individual nanocomponents. The effectiveness of this composite material as an electron transfer film in a new potentiometric membrane sensor for detecting phenylpyruvic acid (in anionic form) was demonstrated. Screening for this metabolic product of phenylalanine in body fluids is of significant diagnostic interest in phenylketonuria (dementia), viral hepatitis, and alcoholism. The developed sensor showed a stable and fast Nernstian response for phenylpyruvate ions in aqueous solutions over the wide linear concentration range of 5 × 10−7–1 × 10−3 M, with a detection limit of 10−7.2 M.
1 January 2023 in Russian Journal of Inorganic Chemistry
An ion-selective electrode (ISE) based on a plasticized polyvinyl chloride membrane chemically doped with tetradecylammonium octahydrotriborate ([(С10H21)4N+]\([{{{\text{B}}}_{{\text{3}}}}{\text{H}}_{8}^{ - }]\)) has been developed. It is shown that the electrode has a reversible potentiometric response with respect to the octahydrotriborate anion in the presence of a number of other inorganic anions. The influence of the concentration of the electrode-active material and the nature of the plasticizer in the membrane phase on the electrochemical characteristics of the fabricated sensor have been studied. The optimal composition of the ion-sensitive membrane has been found. It has been found that the developed sensor provides a wide range of detectable concentrations of \({{{\text{B}}}_{{\text{3}}}}{\text{H}}_{8}^{ - }\) (1 × 10–7…1 × 10–2) and a low detection limit (10–7.3 M). The new ISE can be recommended for direct potentiometric detection of free octahydrotriborate anions in technological aqueous solutions.