Konstantin Yu. Zhizhin

Dr. Konstantin Yu. Zhizhin


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 December 2022 in Nanosystems: Physics, Chemistry, Mathematics
Verified
Journal Article
Closed access
KZKonstantin Yu. Zhizhin
Konstantin Yu. Zhizhin
ETEugeniy Sergeevich Turyshev
Eugeniy Sergeevich Turyshev
AKA.V. Kopytin
A.V. Kopytin
LSLiliya Shpigun
Liliya Shpigun
NKN.T. Kuznetsov
N.T. Kuznetsov
GBG.I. Betenev
G.I. Betenev

24 January 2025 in Inorganics
Verified
Journal Article
Open access
PDF file
ETEugeniy Sergeevich Turyshev
Eugeniy Sergeevich Turyshev
AGAleksei Golubev
Aleksei Golubev
ABAlexander Yu. Bykov
Alexander Yu. Bykov
KZKonstantin Yu. Zhizhin
Konstantin Yu. Zhizhin
NKNikolay T. Kuznetsov
Nikolay T. Kuznetsov
This paper presents a methodology for the preparation of a new active component for ion-selective membranes, based on a di-substituted sulfonium derivative of the closo-decaborate anion at the apical vertices with the octadecylalkyl substituents 1,10-B10H8(S(C18H37)2)2. This approach is characterized by physicochemical methods of analysis (11B, 1H, 13C NMR spectroscopy, IR spectroscopy and elemental analysis). The compound obtained is used as an active component of a PVC membrane selective to terbinafine hydrochloride. The sensor developed is highly selective to the drug to be detected, has a linearity range of 4.0 × 10−8–1.0 × 10−2 and a detection limit of 1.0 × 10−8, and can detect terbinafine hydrochloride in the pH range of 3 to 6.

27 November 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
ETEugeniy Sergeevich Turyshev
Eugeniy Sergeevich Turyshev
ABAlexander Yu. Bykov
Alexander Yu. Bykov
AGAleksei Golubev
Aleksei Golubev
KZKonstantin Yu. Zhizhin
Konstantin Yu. Zhizhin
NKNikolay T. Kuznetsov
Nikolay T. Kuznetsov
This paper presents a methodology for the preparation of a new active component for ion-selective membranes, based on a di-substituted sulfonium derivative of the closo-decaborate anion at the apical vertices with octadecylalkyl substituents 1,10-B10H8(S(C18H37)2)2. This approach is characterised by physicochemical methods of analysis (11B, 1H, 13C NMR spectroscopy, IR spectroscopy and elemental analysis). The compound obtained was used as an active component of a PVC-membrane selective to terbinafine hydrochloride. The sensor developed is highly selective to the drug to be detected, and has a linearity range of 4.0 × 10-8 – 1.0 × 10-2 and a detection limit of 1.0 × 10-8, and can detect terbinafine hydrochloride in the pH range of 3 to 6.