Xianliang Wang

Dr. Xianliang Wang

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Journal of Contemporary Brachytherapy
Verified
Journal Article
Open access
HHHai Hu
Hai Hu
QYQiang Yang
Qiang Yang
JLJie Li
Jie Li
PWPei Wang
Pei Wang
BTBin Tang
Bin Tang
JLJinyi Lang
Jinyi Lang
Introduction Motivated by recent advances in deep learning, the purpose of this study was to investigate a deep learning method in automatic segment and reconstruct applicators in computed tomography (CT) images for cervix brachytherapy treatment planning. Material and methods U-Net model...

31 May 2022 in Photonics
Verified
Journal Article
Open access
PDF file
XWXianliang Wang
Xianliang Wang
LLLi Lintao
Li Lintao
JLJie Li
Jie Li
PWPei Wang
Pei Wang
JLJinyi Lang
Jinyi Lang
Yuanjie YangYuanjie Yang
Yuanjie Yang
Malignant tumors rank as a leading cause of death worldwide. Accurate diagnosis and advanced treatment options are crucial to win battle against tumors. In recent years, Cherenkov luminescence (CL) has shown its technical advantages and clinical transformation potential in many important fields, particularly in tumor diagnosis and treatment, such as tumor detection in vivo, surgical navigation, radiotherapy, photodynamic therapy, and the evaluation of therapeutic effect. In this review, we summarize the advances in CL for tumor diagnosis and treatment. We first describe the physical principles of CL and discuss the imaging techniques used in tumor diagnosis, including CL imaging, CL endoscope, and CL tomography. Then we present a broad overview of the current status of surgical resection, radiotherapy, photodynamic therapy, and tumor microenvironment monitoring using CL. Finally, we shed light on the challenges and possible solutions for tumor diagnosis and therapy using CL.

29 September 2022 in Cancers
Verified
Journal Article
Open access
PDF file
AWAiping Wen
Aiping Wen
XWXianliang Wang
Xianliang Wang
BWBingjie Wang
Bingjie Wang
CYChuanjun Yan
Chuanjun Yan
JLJingyue Luo
Jingyue Luo
JLJie Li
Jie Li
High-dose-rate (HDR) brachytherapy (BT) is an essential treatment for cervical cancer, one of the most prevalent gynecological malignant tumors. In HDR BT, high radiation doses can be delivered to the tumor target with the minimum radiation doses to organs at risk. Despite the wide use of the small HDR 192Ir source, as the technique has improved, the HDR 60Co source, which has the same miniaturized geometry, has also been produced and put into clinical practice. Compared with 192Ir (74 days), 60Co has a longer half-life (5.3 years), which gives it a great economic advantage for developing nations. The aim of the study was to compare 60Co and 192Ir sources for HDR BT in terms of both dosimetry and clinical treatment. The results of reports published on the use of HDR BT for cervical cancer over the past few years as well as our own research show that this treatment is safe and it is feasible to use 60Co as an alternative source.

21 July 2025 in Frontiers in Oncology
Verified
Journal Article
Open access
PDF file
FYFeng Yang
Feng Yang
JWJunxiang Wu
Junxiang Wu
Lucia Clara OrlandiniLucia Clara Orlandini
Lucia Clara Orlandini
HLHeng Li
Heng Li
XWXianliang Wang
Xianliang Wang
Radiotherapy plays a crucial role in cancer treatment. Spatially fractionated radiotherapy (SFRT) has garnered significant interest as a therapeutic strategy that delivers alternating regions of high and low radiation doses, thereby optimizing the therapeutic ratio by minimizing damage to adjacent normal tissues while achieving tumoricidal effects. Proton minibeam radiotherapy (pMBRT), a cutting-edge iteration within the SFRT paradigm, has attracted considerable attention owing to its purported benefits in dose distribution optimization, enhanced tumor control, and superior preservation of normal tissue. This manuscript presents an extensive evaluation of different applications of pMBRT, with a focus on the outcomes observed in preclinical research studies. Additionally, we explored the challenges faced in translating pMBRT from research to clinical practice, while also highlighting the significant potential this technique holds for the future of cancer treatment.

13 December 2017 in Cancers
Verified
Journal Article
Open access
PDF file
XWXianliang Wang
Xianliang Wang
YLYupeng Li
Yupeng Li
Xiaodong ZhangXiaodong Zhang
Xiaodong Zhang
HLHeng Li
Heng Li
KMKoichi Miyazaki
Koichi Miyazaki
XZXiaorong Zhu
Xiaorong Zhu
A mini-ridge filter is often used to widen the Bragg peak in the longitudinal direction at low energies but not high energies. To facilitate the clinical use of a mini-ridge filter, we performed a planning study for the feasibility of a mini-ridge filter as an integral part of the synchrotron nozzle (IMRF). Dose models with and without IMRF were commissioned in a commercial Treatment planning system (TPS). Dosimetric characteristics in a homogenous water phantom were compared between plans with and without IMRF for a fixed spread-out Bragg peak width of 4 cm with distal ranges varying from 8 to 30 g/cm2. Six clinical cases were then used to compare the plan quality between plans. The delivery efficiency was also compared between plans in both the phantom and the clinical cases. The Bragg peak width was increased by 0.18 cm at the lowest energy and by only about 0.04 cm at the highest energy. The IMRF increased the spot size (σ) by up to 0.1 cm at the lowest energy and by only 0.02 cm at the highest energy. For the phantom, the IMRF negligibly affected dose at high energies but increased the lateral penumbra by up to 0.12 cm and the distal penumbra by up to 0.06 cm at low energies. For the clinical cases, the IMRF slightly increased dose to the organs at risk. However, the beam delivery time was reduced from 18.5% to 47.1% for the lung, brain, scalp, and head and neck cases, and dose uniformities of target were improved up to 2.9% for these cases owing to the reduced minimum monitor unit effect. In conclusion, integrating a mini-ridge filter into a synchrotron nozzle is feasible for improving treatment efficiency without significantly sacrificing the plan quality.

20 October 2020 in Frontiers in Oncology
Verified
Journal Article
Open access
PDF file
XWXianliang Wang
Xianliang Wang
PWPei Wang
Pei Wang
BTBin Tang
Bin Tang
SKShengwei Kang
Shengwei Kang
QHQing Hou
Qing Hou
JLJie Li
Jie Li
Purpose: To investigate an implementation method and the results of an inverse dose optimization algorithm, Gradient Based Planning Optimization (GBPO), for three-dimensional brachytherapy. Methods: The GBPO used a quadratic objective function, and a dwell time modulation item was added to the objective function to restrict the dwell time variance. We retrospectively studied 4 cervical cancer patients using different applicators and 15 cervical cancer patients using the Fletcher applicator. We assessed the plan quality of GBPO by isodose lines for the patients using different applicators. For the 15 patients using the Fletcher applicator, we utilized dose-volume histogram (DVH) parameters of HR-CTV (D100%, V150%) and organs at risk (OARs) (D0.1cc, D1cc, D2cc) to evaluate the difference between the GBPO plans and the IPSA (Inverse Planning Simulated Annealing) plans, as well as the GBPO plans and the Graphic plans. Results: For the 4 patients using different applicators, the dose distributions are conformable. For the 15 patients using the Fletcher applicator, when the dwell time modulation factor (DTMF) is less than 20, the dwell time deviation reduces quickly; however, after the DTMF increased to 100, the dwell time deviation has no remarkable change. The difference in dosimetric parameters between the GBPO plans and the IPSA plans is not statistically significant (P>0.05). The GBPO plans have a higher D100% (3.57 ± 0.36, 3.38 ± 0.34; P<0.01) and a lower V150% (55.73 ± 4.06, 57.75 ± 3.79; P<0.01) than those of the Graphic plans. The differences in other DVH parameters are negligible between the GBPO plans and the Graphic plans. Conclusions: The GBPO plans have a comparable quality as the IPSA plans and the Graphic plans for the studied cervical cancer cases. The GBPO algorithm could be integrated into a three-dimensional brachytherapy treatment planning system after studying more sites.