Yoshifumi Ogami

Prof. Yoshifumi Ogami

orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 January 2020 in Energies
Verified
Journal Article
Open access
PDF file
GNGombosuren Nyamsuren
Gombosuren Nyamsuren
YOYoshifumi Ogami
Yoshifumi Ogami
AHAsada Hiroyuki
Asada Hiroyuki
The demand for internal combustion engines remains high for mobile power sources in all fields due to their low costs, running distance capacity, charging reliability, and heavy driving durability. However, air pollution, efficiency, and environmental factors make this more challenging. According to recent research, using a fueled prechamber can lead to lean combustion in the main chamber, resulting in increased efficiency, reduced fuel consumption, and reduced toxic emissions. However, difficulties in producing a fueled prechamber for commercial engines include mixture and soot formation problems in the limited space of the prechamber, and limited research on the charging possibility of the unfueled prechamber. A removable prechamber is advantageous for used vehicles because an engine redesign is not required. Therefore, we proposed to use an unfueled prechamber to enhance the lean burning efficiency of the spark ignited (SI) engine and explore the possibility of charging an unfueled, unscavenged prechamber with a fuel-rich mixture. Consequently, investigating the possibility of filling an unfueled prechamber with a fuel-rich mixture without additional fuel delivery or an air control system was the aim of this study. For this purpose, the charge flowrate of the centrally located unfueled prechamber is extensively investigated by using Computational Fluid Dynamics (CFD), through its design. As a result, a realizable charge flow was detected for the unfueled prechamber in two periods in the inlet and compression strokes. Most importantly, we found fluctuation phenomena in mass flow rates at the inlet stroke directing a charge flow of the richer mixture into an unfueled prechamber without additional systems. Moreover, keeping the charged rich mixture inside the prechamber during the compression stroke is as important as charging the prechamber with the fuel-rich mixture. The study will enable us to produce a removable prechamber to improve the combustion efficiency of port injected engines.

14 November 2017 in Sensors
Verified
Journal Article
Open access
PDF file
YOYoshifumi Ogami
Yoshifumi Ogami
NMNaoya Murakita
Naoya Murakita
Koji FukudomeKoji Fukudome
Koji Fukudome
The sensor response has been reported to become highly nonlinear when the acceleration added to a thermal accelerator is very large, so the same response can be observed for two accelerations with different magnitudes and opposite signs. Some papers have reported the frequency response for the horizontal acceleration to be a first-order system, while others have reported it to be a second-order system. The response for the vertical acceleration has not been studied. In this study, computational experiments were performed to examine the step and frequency responses of a three-axis thermal accelerometer. The results showed that monitoring the temperatures at two positions and making use of cross-axis sensitivity allow a unique acceleration to be determined even when the range of the vertical acceleration is very large (e.g., −10,000–10,000 g). The frequency response was proven to be a second-order system for horizontal acceleration and a third-order system for vertical acceleration.

5 March 2021 in Trends in Computer Science and Information Technology
Verified
Journal Article
Open access
PDF file
YOYoshifumi Ogami
Yoshifumi Ogami
In the direct simulation Monte Carlo method and multi-phase flow calculations, structured and unstructured grid systems for complex geometries necessitate the time-consuming process of searching a large number of cells to position target particles. This paper proposes effective computational methods for particle searching and positioning that are applicable to structured and unstructured grid systems. Firstly, two methods are introduced to limit the cells to search: the surrounding cell registration method and the Cartesian cell registration method. In the case of two-dimensional potential flow around a circular cylinder, as an application of the proposed methods, it is demonstrated that the surrounding cell registration method is 232 times faster than the method of searching all the cells until the cells occupied by the target particles are found, whereas the Cartesian cell registration method is 200 times faster with the appropriate parameters. Secondly, a method called the area comparison method is introduced to position a target particle and find the exit edge of the cell at which a trajectory of the particle exits. It is demonstrated that the area comparison method can position particles 1.15–1.2 times faster than particle-to-the-left positioning because the latter is implemented with multiple if-statements, while the former has only one.

18 January 2010 in Fluid Dynamics Research
Verified
Journal Article
Closed access
YOYoshifumi Ogami
Yoshifumi Ogami
SAS Akishita
S Akishita

7 September 2022 in Sensors
Verified
Journal Article
Open access
PDF file
KSKamran Siddique
Kamran Siddique
YOYoshifumi Ogami
Yoshifumi Ogami
In this study, a new technique has been proposed by numerical simulations by which multiple physical quantities can be simultaneously measured. The sensor is a modification of existing physical sensors such as a thermal motion sensor. Simultaneous measurement of acceleration and rotation is presented herein. Cross-axis sensitivity is employed such that output sensitivities observed at two perpendicular axes, X and Y sensor data, are related to the input physical quantities. The physics involved in measurement is similar to that of a conventional thermal accelerometer, hence the governing equations predicting the sensor response are based on the conservation of mass, momentum, and energy, and are discretized by using a commercially available software FLUENT. A series of computational studies are conducted and using these studies a novel idea is proposed in which the maximum temperature values are obtained at various positions around a heating source and are correlated with the applied acceleration and rotational speed. A parametric study is also presented to find the optimum distance between the heater and sensors. The influence of changing gas medium on the temperature curves has also been examined and it has been concluded that CO2 generates the maximum performance due to its higher density and lower viscosity.

1 June 2023 in Sensors
Verified
Journal Article
Open access
PDF file
KSKamran Siddique
Kamran Siddique
YOYoshifumi Ogami
Yoshifumi Ogami
Cross-axis sensitivity is generally undesirable, and lower values are required for the accurate performance of a thermal accelerometer. In this study, errors in devices are utilized to simultaneously measure two physical quantities of an unmanned aerial vehicle (UAV) in the X-, Y-, and Z-directions, i.e., where three accelerations and three rotations can also be simultaneously measured using a single motion sensor. The 3D structures of thermal accelerometers were designed and simulated in a FEM simulator using commercially available FLUENT 18.2 software Obtained temperature responses were correlated with input physical quantities, and a graphical relationship was created between peak temperature values and input accelerations and rotations. Using this graphical representation, any values of acceleration from 1g to 4g and rotational speed from 200 to 1000°/s can be simultaneously measured in all three directions.