The intelligent substations should be developed to perform multifunction operations, including power flow control, voltage regulation, and cost-effective power quality (PQ) improvement. In this article, an intelligent substation by a distribution transformer integrated with a capacitive-coupling winding tap injection static synchronous compensator (CWTI-DSTATCOM) is proposed for balance and unbalance operations. Compared with the state-of-the-art approaches, CWTI-DSTATCOM can operate at a low dc voltage with a small active inverter rating, which also can provide distributed voltage, reactive, and unbalanced current compensation. The power rating reduction mechanism is mathematically revealed via balance and unbalance compensation analysis, which is further used to determine the optimal inverter power rating of unbalance operation via an optimal LC filter design method. Furthermore, a comprehensive compensation control strategy is developed to coordinate the transformer taps and the active inverter under balanced and unbalanced operations. Simulation and real-time digital simulator hardware-in-the-loop experiments are performed to prove the validity and effectiveness of the proposed topology over inverter rating reduction and PQ enhancement.

7 October 2024 in IEEE Transactions on Consumer Electronics
Verified
Journal Article
Closed access
ZBZiyi Bai
Ziyi Bai
Da XuDa Xu
Da Xu
Bin ZhouBin Zhou
Bin Zhou
XYXiaodong Yang
Xiaodong Yang
HYHanyu Yang
Hanyu Yang
JLJu Liu
Ju Liu
Mobile battery energy storage systems (MBESs), also called power-to-mobility, have been field-validated as backup generation resources. However, the role of multi-energy coordination towards resilient distribution systems (DSs) against large area disasters is still not yet involved. To cope with such challenges, this paper proposes a computing optimal resilient operation model for post-disaster microgrid-penetrated DS recovery based on the energy-to-mobility approach. In this model, mobile multi-energy storages (MMESs) are invested and routed based on their different transportation mobility, while DS with consumer-side biogas-solar-wind multi-energy microgrids are topologized by network reconfiguration. The coordinated resilient operation of different recovery actions of DS, MMESs, and consumer-side microgrids is a difficult optimization problem as results of its inherent nonconvexities, temporal-spatial mobility and strong multi-energy couplings. The original mixed-integer non-linear programming (MINLP) problem is thus equivalently linearized and reformulated into a mixed-integer linear programming (MILP) for computation performance improvement. The proposed methodology is benchmarked and performed on a modified radial DS with three consumer-side microgrids. Numerical studies demonstrate the effectiveness and superiority of the energy-to-mobility scheme over MBESs on system resilient level and economy.

7 July 2022 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
ZXZeng Xiang
Zeng Xiang
YPYing Pang
Ying Pang
ZBZiyi Bai
Ziyi Bai
LWLei Wang
Lei Wang
CWChi-Kong Wong
Chi-Kong Wong
MWMan-Chung Wong
Man-Chung Wong
Among the exiting multifunctional photovoltaic (PV) inverters (MPVIs), the main challenges are low efficiency, undesired harmonic emission, and weak compensation capability. In this article, a theoretical study via rotating phasor to the PV curves is first proposed to figure out the undesired harmonic emission puzzle in different PV inverters as well as to provide the foundation for PV inverters to achieve multifunction ability under varying load conditions. On the other hand, a single-phase time-sharing miniboost MPVI with different operation modes is proposed and operated under varying PV and load conditions in order to improve its efficiency and compensation capability without undesired harmonic emission. Corresponding control strategy and stability analysis are given. Finally, a 1.5-kW prototype is presented, benchmarked against harmonic emission issues, compensation capability, and efficiency. Experimental results clearly indicate that the proposed topology and control method can perform the active power injection and power quality compensation with better efficiency and avoiding harmonic emission into the grid dynamically.

9 January 2023 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
YPYing Pang
Ying Pang
ZBZiyi Bai
Ziyi Bai
ZXZeng Xiang
Zeng Xiang
LWLei Wang
Lei Wang
CWChi-Kong Wong
Chi-Kong Wong
MWMan-Chung Wong
Man-Chung Wong
In this article, the concept of fusion topology is proposed to tackle the development trend and control issue of hybrid parallel multiconverter applications and to achieve better performance in transient and steady-state operations. Compared to previously fixed frequency compensation strategies, data-driven finite-state machine (FSM) control can determine which voltage source converter (VSC) dominates the operation or whether two VSCs operate simultaneously rather than giving the specific target operation to each VSC alone. The results are verified by a real-time digital simulator (RTDS) with the hardware-in-the-loop (HIL) experiments. The 20 kVA RTDS experimental results show that the transient time is shorter by 53.8%–85.7%, and power loss is smaller by 28.6%–78.3%, respectively, compared with the previous methods.

7 April 2023 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
ZBZiyi Bai
Ziyi Bai
Da XuDa Xu
Da Xu
TWTao Wang
Tao Wang
MWMan-Chung Wong
Man-Chung Wong
This paper proposes a cascaded multilevel battery energy storage based parallel dynamic voltage compensator (DVC) for medium voltage industrial distribution systems. In this parallel DVC, fast switch is series-connected for voltage sag detection, and cascaded multilevel battery energy storage is parallel-connected for voltage support during the voltage sag period. According to the grid-side voltage sags or not, corresponding circuits and three-layer control strategies are developed. While the feedforward proportional–integral (PI) control method is adopted in the outer layer to track the ideal compensation voltage when the grid-side voltage sags, the ideal compensation current when the grid-side voltage does not sag is obtained through battery charging current as well as reactive power, harmonics, and negative sequence load current components. In order to cope with parameter differences in cascaded multilevel battery energy storage, the middle layer interphase and the inner layer intermodular state of charge (SOC) equalization control are adopted in two scenarios. Furthermore, the parallel DVC is quantitatively compared with series DVC in the aspect of required battery capacity, and their advantages and disadvantages are systematically analyzed. Case studies are performed to verify the effectiveness and superiority of the proposed methodology on voltage support.

5 January 2023 in Frontiers in Energy Research
Verified
Journal Article
Open access
DXDa Xu
Da Xu
FZFeili Zhong
Feili Zhong
ZBZiyi Bai
Ziyi Bai
The inherent intermittency of high-penetrated renewable energy poses economic and reliable issues of microgrid energy management. This study proposes a two-layer predictive energy management system (PEMS) for high-renewable multi-energy microgrid (MEM). In this MEM, geothermal, solar, and wind energy is converted and conditioned for electricity, thermal, and gas supplies, in which multi-energy complementarities are fully exploited based on electrolytic thermos-electrochemical effects. The proposed microgrid multi-energy management is a complicated and cumbersome problem because of their increasingly tight energy couplings and uncertainties of renewable energy sources (RESs). This intractable problem is thus processed by means of a two-layer PEMS with different time scales, where the system operating costs are minimized in the upper layer and the renewable fluctuations are coped with in the lower layer. Simulation studies on a high-renewable MEM are provided to indicate its effectiveness and superiority over a single time scale scheme. Simulations results show that the operating cost can be reduced by 22.2% with high RESs accommodation.