This study provides the design, control and comparative analysis of the proposed LCLC coupling hybrid active power filter (LCLC‐HAPF). Compared with the conventional L filter coupling active power filters (APFs), LC filter and LCL filter coupling HAPFs (LC‐HAPFs and LCL‐HAPFs), the proposed LCLC‐HAPF provides better switching frequency harmonics elimination, lower dc‐link voltage rating and switching loss. Although the LCLC‐HAPF has some advantages, two main challenges will still be confronted in practical implementations. Those are stability problems caused by resonance of LCLC filter, and parameter design for the LCLC filter. In this study, a new active damping method is proposed to overcome the high order resonance problem existing in the proposed LCLC‐HAPF. After that, the stability analysis and parameter design are given for the proposed LCLC‐HAPF. Finally, the effectiveness of the proposed LCLC‐HAPF topology is validated through both simulation and experimental studies in comparison with the conventional APFs and HAPFs.
29 June 2020 in IEEE Transactions on Transportation Electrification
The electrical locomotives are treated as single-phase nonlinear loads, which can cause the low power factor, high contents of harmonic currents, and negative-sequence current. The power quality conditioners are widely used for solving the power quality issues in railway power system. In power quality conditioners, the coupled impedance can affect the operation voltage, compensation range and performance. Therefore, this paper discusses the effect of different coupled impedances in conditioners included fixed inductive impedance, fixed capacitive impedance and adaptive impedance. Moreover, an adaptive impedance hybrid power quality conditioner (AI-HPQC) is proposed in comparison with inductive coupled railway power quality compensator (RPC) and capacitive coupled hybrid power quality conditioner (HPQC). Furthermore, a control method for the AI-HPQC is proposed for the coordination control of the adaptive impedance part and the active inverter part. The validities of the RPC, HPQC and proposed AI-HPQC are verified by both simulation and experimental results.
19 August 2020 in IEEE Transactions on Power Electronics
Previous researches on space vector modulation (SVM) in active power filters (APFs) topologies find that compared with sinusoidal pulse width modulation (SPWM), the SVM offers a better harmonic spectrum and has 15.47% more voltage utilization. The paper not only proposes SVM for hybrid active power filters (HAPFs) but also answers the following questions: 1) Under what conditions both filters are equivalent to one another 2) Which filter can enhance better tracking ability and better performance 3) How the coupling component parameters and dc voltage affect the performance of both filters The representative simulation and experimental results are given to verify the discussions. The conclusions can be application guidelines for the design of inductive and capacitive coupling inverters (e.g., APFs and HAPFs) in smart grids and development of energy internet due to their generalities to applications.
30 March 2021 in IEEE Transactions on Industrial Electronics
In this article, we present an adaptive broadband thyristor-controlled impedance matching network (TCIMN) for increasing power utilization from a power amplifier to the loads. Different from the conventional passive impedance matching methods, the proposed one can achieve load impedance matching under a wide frequency range of power amplifiers. First, the operation principle of TCIMN is introduced mathematically. Based on that, the parameter design method is proposed based on the required frequency range. Moreover, the operating range and harmonic analyses are provided to give the TCIMN firing angle operating ranges under different frequencies and alleviate the potential harmonic problem caused by thyristors. To control the proposed TCIMN, the dynamic impedance identification is applied to match the load reactive power adaptively. Finally, the simulation and experimental results of a prototype are given to demonstrate the validity of the proposed TCIMN, analysis, and control method. The results clearly show that the proposed TCIMN can adaptively match the load impedance for the different loads and broadband frequency range. More importantly, the power amplifier power utilization factor is significantly improved without causing harmonic pollutions.
21 October 2020 in IEEE Transactions on Industrial Electronics
In remote areas, the distribution networks are usually under-developed, thus three-phase medium-voltage grids may provide a low-cost power supply solution for residential buildings. A new centralized approach topology of three-port power hub converter, which consists of a V/V transformer, a back-to-back inverter, and a static VAR compensator with adaptive impedance, is proposed for remote area power supply. The proposed three-port converter interfaces two bidirectional power ports connecting three-phase AC grid and DC grid, respectively, and one unidirectional power port connects AC loads. The functions of the proposed converter are the bidirectional power flow control between three-phase AC grid and DC grid and power quality compensation to the three-phase AC grid. Finally, to verify the validity of the proposed three-port converter and its control performance, different simulation and experimental cases are implemented under different operation conditions.
9 March 2022 in IEEE Transactions on Industrial Electronics
The intelligent substations should be developed to perform multifunction operations, including power flow control, voltage regulation, and cost-effective power quality (PQ) improvement. In this article, an intelligent substation by a distribution transformer integrated with a capacitive-coupling winding tap injection static synchronous compensator (CWTI-DSTATCOM) is proposed for balance and unbalance operations. Compared with the state-of-the-art approaches, CWTI-DSTATCOM can operate at a low dc voltage with a small active inverter rating, which also can provide distributed voltage, reactive, and unbalanced current compensation. The power rating reduction mechanism is mathematically revealed via balance and unbalance compensation analysis, which is further used to determine the optimal inverter power rating of unbalance operation via an optimal LC filter design method. Furthermore, a comprehensive compensation control strategy is developed to coordinate the transformer taps and the active inverter under balanced and unbalanced operations. Simulation and real-time digital simulator hardware-in-the-loop experiments are performed to prove the validity and effectiveness of the proposed topology over inverter rating reduction and PQ enhancement.