María Noel Pereyra

Prof. María Noel Pereyra

Departamento de Construcción - IET, Facultad de Ingeniería, Universidad de la República, Montevideo, Uruguay
orcid
Prof. Agregada

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

1 July 2026 in DYNA Ingenieria e Industria
Verified
Journal Article
Closed access
PVPatricia Elizabet Vila
Patricia Elizabet Vila
María Noel PereyraMaría Noel Pereyra
María Noel Pereyra
The production of portland cement, used as a binder in concrete mixtures, is one of the main sources of CO2 emissions and environmental impact worldwide. In particular, selfcompacting concrete (SCC) requires high amounts of fine materials (particles smaller than 0.15 mm) to ensure proper flowability, stability, and filling capacity without segregation. In this context, the present study analyses the fresh and hardened behaviour of SCC mixtures incorporating powder obtained from a granodiorite rock quarry and a limestone quarry as partial replacements of cement. Five mixtures were designed: one reference mix without replacement and four with 30% and 50% cement replacement by quarry powder. Flowability, passing ability, viscosity, compressive strength, and water penetration depth were evaluated. The results show that mixtures with 30% replacement met the SCC requirements, exhibiting good workability without segregation and compressive strengths ranging from 24.6 MPa to 50.5 MPa. Moreover, all mixtures demonstrated low water penetration, even those with high water-to-cementitious material ratios. This study emphasizes the value of quarry by-products in reducing both waste accumulation and the environmental impact associated with portland cement.

15 October 2026
Verified
Book Chapter
Open access
PDF file
PCP. Codina
P. Codina
JCJ. Cabrera
J. Cabrera
PVPatricia Elizabet Vila
Patricia Elizabet Vila
María Noel PereyraMaría Noel Pereyra
María Noel Pereyra
This study presents the application of a life cycle assessment (LCA)-based calculation method to support sustainable concrete mix design in Uruguay. The aim was to evaluate the environmental performance of traditional and alternative concrete mixtures with comparable technical performance, representative of ready-mix concrete production in Uruguay. The functional unit was 1 m3 of concrete. Three types of concrete were analyzed: conventional concrete (CC) with two strength levels (25 MPa and 40 MPa) and a self-compacting concrete (SCC). For each case, reference mixtures produced with Portland cement were compared with alternative mixtures incorporating supplementary materials. In CC mixtures, calcined clay (metakaolin) was used as a partial replacement of Portland cement, while in SCC mixtures the cement was partially replaced by quarry crushing fillers obtained from granodiorite and limestone stone powder. The LCA system boundaries were defined as cradle-to-construction site (A1-A4) according to UNIT-ISO 21930, including raw material production, transport to the batching plant, concrete production, and delivery to the construction site. Life cycle inventory data were mainly obtained from the Ecoinvent v3.x database and complemented with local information. Environmental impacts were evaluated using the ReCiPe 2016 Midpoint method, considering the impact categories defined within this method. The results indicate that reducing Portland cement content through the use of calcined clay and quarry fillers significantly decreases environmental impacts, particularly in climate change and fossil resource scarcity, while maintaining the required technical performance

8 January 2025 in Buildings
Verified
Journal Article
Open access
PDF file
ALAlvaro Antonio Leez
Alvaro Antonio Leez
María Noel PereyraMaría Noel Pereyra
María Noel Pereyra
PVPatricia Elizabet Vila
Patricia Elizabet Vila
On 6 August 2022, a fire devastated 80% of the Punta del Este Shopping Center in Maldonado, Uruguay. Originating in the kitchen of a supermarket, the fire ravaged the shopping center for 72 h before being brought under control. This article outlines the studies conducted to assess the fire’s impact on the building’s structure, as well as the strategies and rehabilitation project aimed at ensuring its stability and performance. An in-depth analysis of the concrete, reinforcements, and foundations was carried out using destructive and non-destructive testing. In total, over 150 concrete samples were collected for analysis, and the foundations were studied using indirect methods. Based on these analyses, actions were planned for each area, including structural repairs, reinforcements, or demolition. Due to the tight deadline for resuming commercial activity, special innovative structural solutions were designed to rehabilitate large severely damaged areas with the specific feature of avoiding demolition. This involved altering the static scheme of the structure, incorporating reinforcements and using slabs of the damaged structure as formworks. Complete demolition and subsequent reconstruction would have required timelines incompatible with the clients’ expectations, while the adopted solutions enabled the project to meet its objectives.