David Gutiérrez de Arcos

Mr. David Gutiérrez de Arcos

ITLR, University of Stuttgart, Stuttgart, Baden-Württemberg, Germany
orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
DADavid Gutiérrez de Arcos
David Gutiérrez de Arcos
CWChristian Waidmann
Christian Waidmann
RPRico Poser
Rico Poser
JWJens von Wolfersdorf
Jens von Wolfersdorf
MGMichael Göhring
Michael Göhring
Turbine blades for modern turbomachinery applications often exhibit complex twisted designs that aim to reduce aerodynamic losses, thereby improving the overall machine performance. This results in intricate internal cooling configurations that change their spanwise orientation with respect to the rotational axis. In the present study, the local heat transfer in a generic two-pass turbine cooling channel is investigated under engine-similar rotating conditions (Ro={0…0.50}) through the transient Thermochromic Liquid Crystal (TLC) measurement technique. Three different angles of attack (α={−18.5°;+8°;+46.5°}) are investigated to emulate the heat transfer characteristics in an internal cooling channel of a real turbine blade application at different spanwise positions. A numerical approach based on steady-state Reynolds-averaged Navier–Stokes (RANS) simulations in ANSYS CFX is validated against the experimental method, showing generally good agreement and, thus, qualifying for future heat transfer predictions. Experimental and numerical data clearly demonstrate the substantial impact of the angle of attack on the local heat transfer structure, especially for the radially outward flow of the first passage, owing to the particular Coriolis force direction at each angle of attack. Furthermore, results underscore the strong influence of the rotational speed on the overall heat transfer level, with an enhancement effect for the radially outward flow (first passage) and a reduction effect for the radially inward flow (second passage).

24 July 2025 in Journal of the Global Power and Propulsion Society
Verified
Journal Article
Open access
DADavid Gutiérrez de Arcos
David Gutiérrez de Arcos
CWChristian Waidmann
Christian Waidmann
RPRico Poser
Rico Poser
JWJens von Wolfersdorf
Jens von Wolfersdorf
BJBernhard Jäppelt
Bernhard Jäppelt
KSKlaus Semmler
Klaus Semmler
Optimised internal cooling schemes for turbine blades aim at enhancing the heat transfer between the hot channel walls and the relatively cold fluid while preventing overcooling. Often, a combination of different turbulator types adapted to the specific turbine blade application are required. Prior research has demonstrated that a promising design featuring high heat transfer in exchange for a reasonable pressure loss penalty is achieved through the use of ribs and protrusions. As regards to rotor blades, rotation represents a key factor with a pronounced impact on the secondary flow field, and thus on the heat transfer characteristics. In the present work, local heat transfer measurements using the transient thermochromic liquid crystal (TLC) technique are conducted under engine-similar test conditions in the rotating rig of the Institute of Aerospace Thermodynamics (ITLR) at the University of Stuttgart. A two-pass cooling channel channel with two different turbulator designs is investigated: a ribbed geometry (baseline) and a rib-protrusion geometry with leading edge ribs (enhanced). Additionally, numerical simulations performed with ANSYS CFX support the experimental approach and complement it with flow field visualisations. It is shown that the rib-protrusion compound is able to improve the heat transfer under both rotating and non-rotating conditions. Nevertheless, a strong reduction in heat transfer caused by rotation occurs with the rib-protrusion geometry, especially considering the radially inward flow of the second passage. The importance of rotation on the secondary flow field and thereby on the internal heat transfer is demonstrated, contributing to a better understanding of cooling air usage under engine-realistic test conditions.

2 September 2026 in International Journal of Heat and Mass Transfer
Verified
Journal Article
Open access
PHPaul David Hägele
Paul David Hägele
VSV. Schefthaler
V. Schefthaler
DADavid Gutiérrez de Arcos
David Gutiérrez de Arcos
CWC. Waidmann
C. Waidmann
RPRico Poser
Rico Poser

14 April 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
PHPaul David Hägele
Paul David Hägele
VSVerena Schefthaler
Verena Schefthaler
DADavid Gutiérrez de Arcos
David Gutiérrez de Arcos
CWChristian Waidmann
Christian Waidmann
RPRico Poser
Rico Poser
Transient heat transfer experiments that employ thermochromic liquid crystals (TLCs) provide high‐resolution surface‐temperature data but are hampered by noisy intensity signals, non‐ideal fluid‐temperature steps, and the challenge of resolving multiple TLC responses at pixel level. In this paper we introduce a fully automated analysis framework that (i) smooths and baseline‐corrects raw video data with a Whittaker‐algorithm whose regularisation parameter is explicitly linked to the signal density, (ii) identifies multiple intensity peaks per pixel via interval‐wise detection, and (iii) evaluates the local convective heat transfer coefficient using a stepwise‐partial‐integration (SPI) formulation of Duhamel’s principle. For each pixel, the heat transfer coefficient is determined for each individual TLC indication; the final value is formed by an inverse‐variance weighted average, guaranteeing that the most reliable indication dominates.The methodology is applied to a rotating two-pass cooling channel coated with a stack of two different narrow‐band TLC layers. Compared to conventional analysis using semi-infinite walls, the proposed workflow significantly improves the standard method by automatically detecting the peaks of multiple narrow-band TLCs. To illustrate the benefits of multiple TLCs, the additional information is used in this work to reduce the measurement uncertainty of the experiments. This is feasible because the selection of the optimal indication temperature for the TLCs depends on the heat transfer coefficient and the driving temperature difference at each individual point. Consequently, the results are evaluated post-experiment and weighted according to their respective standard deviations. This entire workflow enables multi-parameter analyses to be carried out in order to determine further variables from single experiments.