Monitoring cerebral oxygenation and metabolism, using a combination of invasive and non-invasive sensors, is vital due to frequent disruptions in hemodynamic regulation across various diseases. These sensors generate continuous high-frequency data streams, including intracranial pressure (ICP) and cerebral perfusion pressure (CPP), providing real-time insights into cerebral function. Analyzing these signals is crucial for understanding complex brain processes, identifying subtle patterns, and detecting anomalies. Computational models play an essential role in linking sensor-derived signals to the underlying physiological state of the brain. Multivariate machine learning models have proven particularly effective in this domain, capturing intricate relationships among multiple variables simultaneously and enabling the accurate modeling of cerebral physiologic signals. These models facilitate the development of advanced diagnostic and prognostic tools, promote patient-specific interventions, and improve therapeutic outcomes. Additionally, machine learning models offer great flexibility, allowing different models to be combined synergistically to address complex challenges in sensor-based data analysis. Ensemble learning techniques, which aggregate predictions from diverse models, further enhance predictive accuracy and robustness. This review explores the use of multivariate machine learning models in cerebral physiology as a whole, with an emphasis on sensor-derived signals related to hemodynamics, cerebral oxygenation, metabolism, and other modalities such as electroencephalography (EEG) and functional near-infrared spectroscopy (fNIRS) where applicable. It will detail the operational principles, mathematical foundations, and clinical implications of these models, providing a deeper understanding of their significance in monitoring cerebral function.
The contemporary monitoring of cerebrovascular reactivity (CVR) relies on invasive intracranial pressure (ICP) monitoring which limits its application. Interest is shifting towards near-infrared spectroscopic regional cerebral oxygen saturation (rSO2)-based indices of CVR which are less invasive and have improved spatial resolution. This study aims to examine and model the relationship between ICP and rSO2-based indices of CVR. Through a retrospective cohort study of prospectively collected physiologic data in moderate to severe traumatic brain injury (TBI) patients, linear mixed effects modeling techniques, augmented with time-series analysis, were utilized to evaluate the ability of rSO2-based indices of CVR to model ICP-based indices. It was found that rSO2-based indices of CVR had a statistically significant linear relationship with ICP-based indices, even when the hierarchical and autocorrelative nature of the data was accounted for. This strengthens the body of literature indicating the validity of rSO2-based indices of CVR and potential greatly expands the scope of CVR monitoring.
Continuous metrics of cerebral autoregulation (CA) assessment have been developed using various multimodal cerebral physiological monitoring devices. However, CA regional disparity remains unclear in states of health and disease. Leveraging existing archived data sources, we preliminarily evaluated regional hemispheric disparity in CA using the near infrared spectroscopy (NIRS)-derived cerebral oximetry index (COx/COx-a). Along with bilateral NIRS, regional cerebral oxygen saturation, arterial blood pressure, cerebral perfusion pressure, and bilateral COx/COx-a were derived using three different temporal resolutions—10 s, 1 min, and 5 min—based on non-overlapping mean values. The regional disparity between hemispheres was evaluated based on median and median absolute deviation. Further, patient-level autoregressive integrative moving average models were calculated for each signal stream and used to generate personalized vector autoregressive models. Multi-variate cerebral physiologic relationships between hemispheres were assessed via impulse response functions and Granger causality analyses. Data from 102 healthy control volunteers, 27 spinal surgery patients, and 95 TBI patients (varying in frontal lobe pathology impacting the optode path; 64 without bifrontal lobe pathology, 15 without left frontal lobe pathology, 11 without right frontal lobe pathology, and 5 with bifrontal lobe pathology) were retrospectively analyzed. For subjects with or without cranial pathology, no difference in COx/COx-a was found between hemispheres regardless of the analytic method. In TBI patients without pathology underneath the NIRS sensor, distant parenchymal injury does not seem to have an effect on the CA of uninjured frontal lobes. Further work is required to characterize regional disparities with multi-channel CA measurements in healthy and disease states.
Artifacts induced during patient monitoring are a main limitation for near-infrared spectroscopy (NIRS) as a non-invasive method of cerebral hemodynamic monitoring. There currently does not exist a robust “gold-standard” method for artifact management for these signals. The objective of this review is to comprehensively examine the literature on existing artifact management methods for cerebral NIRS signals recorded in animals and humans. A search of five databases was conducted based on the Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines. The search yielded 806 unique results. There were 19 articles from these results that were included in this review based on the inclusion/exclusion criteria. There were an additional 36 articles identified in the references of select articles that were also included. The methods outlined in these articles were grouped under two major categories: (1) motion and other disconnection artifact removal methods; (2) data quality improvement and physiological/other noise artifact filtering methods. These were sub-categorized by method type. It proved difficult to quantitatively compare the methods due to the heterogeneity of the effectiveness metrics and definitions of artifacts. The limitations evident in the existing literature justify the need for more comprehensive comparisons of artifact management. This review provides insights into the available methods for artifact management in cerebral NIRS and justification for a homogenous method to quantify the effectiveness of artifact management methods. This builds upon the work of two existing reviews that have been conducted on this topic; however, the scope is extended to all artifact types and all NIRS recording types. Future work by our lab in cerebral NIRS artifact management will lie in a layered artifact management method that will employ different techniques covered in this review (including dynamic thresholding, autoregressive-based methods, and wavelet-based methods) amongst others to remove varying artifact types.
Regional cerebral oxygen saturation (rSO2), a method of cerebral tissue oxygenation measurement, is recorded using non-invasive near-infrared Spectroscopy (NIRS) devices. A major limitation is that recorded signals often contain artifacts. Manually removing these artifacts is both resource and time consuming. The objective was to evaluate the applicability of using wavelet analysis as an automated method for simple signal loss artifact clearance of rSO2 signals obtained from commercially available devices. A retrospective observational study using existing populations (healthy control (HC), elective spinal surgery patients (SP), and traumatic brain injury patients (TBI)) was conducted. Arterial blood pressure (ABP) and rSO2 data were collected in all patients. Wavelet analysis was determined to be successful in removing simple signal loss artifacts using wavelet coefficients and coherence to detect signal loss artifacts in rSO2 signals. The removal success rates in HC, SP, and TBI populations were 100%, 99.8%, and 99.7%, respectively (though it had limited precision in determining the exact point in time). Thus, wavelet analysis may prove to be useful in a layered approach NIRS signal artifact tool utilizing higher-frequency data; however, future work is needed.
Cerebral near-infrared spectroscopy (NIRS) systems have been demonstrated to continuously measure aspects of oxygen delivery and cerebrovascular reactivity. However, it remains unknown whether the prediction of these cerebral physiologic signals into the future is feasible. Leveraging existing archived data sources, four point and interval-forecasting methods using autoregressive integrative moving average (ARIMA) models were evaluated to assess their ability to predict NIRS cerebral physiologic signals. NIRS-based regional cerebral oxygen saturation (rSO2) and cerebral oximetry index signals were derived in three temporal resolutions (10 s, 1 min, and 5 min). Anchored- and sliding-window forecasting, with varying model memory, using point and interval approaches were used to forecast signals using fitted optimal ARIMA models. The absolute difference in the forecasted and measured data was evaluated with median absolute deviation, along with root mean squared error analysis. Further, Pearson correlation and Bland–Altman statistical analyses were performed. Data from 102 healthy controls, 27 spinal surgery patients, and 101 traumatic brain injury patients were retrospectively analyzed. All ARIMA-based point and interval prediction models demonstrated small residuals, while correlation and agreement varied based on model memory. The ARIMA-based sliding-window approach performed superior to the anchored approach due to data partitioning and model memory. ARIMA-based sliding-window forecasting using point and interval approaches can forecast rSO2 and the cerebral oximetry index with reasonably small residuals across all populations. Correlation and agreement between the predicted versus actual values varies substantially based on data-partitioning methods and model memory. Further work is required to assess the ability to forecast high-frequency NIRS signals using ARIMA and ARIMA-variant models in healthy and cranial trauma populations.