Abrar Islam

Mr. Abrar Islam

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 August 2024 in Micro
Verified
Journal Article
Open access
PDF file
AIAbrar Islam
Abrar Islam
NVNuray Vakitbilir
Nuray Vakitbilir
NANátaly Domingues Almeida
Nátaly Domingues Almeida
Rodrigo FrançaRodrigo França
Rodrigo França
Recent advancements in 3D-bioprinting technology have sparked a growing interest in its application for brain repair, encompassing tissue regeneration, drug delivery, and disease modeling. This literature review examines studies conducted over the past five years to assess the current state of research in this field. Common bioprinting methods and key parameters influencing their selection are explored, alongside an analysis of the diverse types of bioink utilized and their associated parameters. The extrusion-based 3D-bioprinting method emerged as the most widely studied and popular topic, followed by inkjet-based and laser-based bioprinting and stereolithography. Regarding bioinks, fibrin-based and collagen-based bioinks are predominantly utilized. Furthermore, this review elucidates how 3D bioprinting holds promise for neural tissue repair, regeneration, and drug screening, detailing the steps involved and various approaches employed. Neurovascular 3D printing and bioscaffold 3D printing stand out as the top two preferred methods for brain repair. The recent studies’ shortcomings and potential solutions to address them are also examined and discussed. Overall, by synthesizing recent findings, this review provides valuable insights into the potential of 3D bioprinting for advancing brain repairment strategies.

20 December 2024 in Sensors
Verified
Journal Article
Open access
PDF file
NVNuray Vakitbilir
Nuray Vakitbilir
AIAbrar Islam
Abrar Islam
AGAlwyn Gomez
Alwyn Gomez
KSKevin Y Stein
Kevin Y Stein
LFLogan Froese
Logan Froese
FZFrederick Zeiler
Frederick Zeiler
Monitoring cerebral oxygenation and metabolism, using a combination of invasive and non-invasive sensors, is vital due to frequent disruptions in hemodynamic regulation across various diseases. These sensors generate continuous high-frequency data streams, including intracranial pressure (ICP) and cerebral perfusion pressure (CPP), providing real-time insights into cerebral function. Analyzing these signals is crucial for understanding complex brain processes, identifying subtle patterns, and detecting anomalies. Computational models play an essential role in linking sensor-derived signals to the underlying physiological state of the brain. Multivariate machine learning models have proven particularly effective in this domain, capturing intricate relationships among multiple variables simultaneously and enabling the accurate modeling of cerebral physiologic signals. These models facilitate the development of advanced diagnostic and prognostic tools, promote patient-specific interventions, and improve therapeutic outcomes. Additionally, machine learning models offer great flexibility, allowing different models to be combined synergistically to address complex challenges in sensor-based data analysis. Ensemble learning techniques, which aggregate predictions from diverse models, further enhance predictive accuracy and robustness. This review explores the use of multivariate machine learning models in cerebral physiology as a whole, with an emphasis on sensor-derived signals related to hemodynamics, cerebral oxygenation, metabolism, and other modalities such as electroencephalography (EEG) and functional near-infrared spectroscopy (fNIRS) where applicable. It will detail the operational principles, mathematical foundations, and clinical implications of these models, providing a deeper understanding of their significance in monitoring cerebral function.

1 June 2024 in Physiological Measurement
Verified
Journal Article
Open access
AIAbrar Islam
Abrar Islam
LFLogan Froese
Logan Froese
TBTobias Bergmann
Tobias Bergmann
AGAlwyn Gomez
Alwyn Gomez
ASAmanjyot Singh Sainbhi
Amanjyot Singh Sainbhi
FZFrederick Zeiler
Frederick Zeiler
Objective. Continuous monitoring of cerebrospinal compliance (CC)/ cerebrospinal compensatory reserve (CCR) is crucial for timely interventions and preventing more substantial deterioration in the context of acute neural injury, as it enables the early detection of abnormalities in intracranial pressure (ICP). However, to date, the literature on continuous CC/CCR monitoring is scattered and occasionally challenging to consolidate. Approach. We subsequently conducted a systematic scoping review of the human literature to highlight the available continuous CC/CCR monitoring methods. Main results. This systematic review incorporated a total number of 76 studies, covering diverse patient types and focusing on three primary continuous CC or CCR monitoring metrics and methods—Moving Pearson’s correlation between ICP pulse amplitude waveform and ICP, referred to as RAP, the Spiegelberg Compliance Monitor, changes in cerebral blood flow velocity with respect to the alternation of ICP measured through transcranial doppler (TCD), changes in centroid metric, high frequency centroid (HFC) or higher harmonics centroid (HHC), and the P2/P1 ratio which are the distinct peaks of ICP pulse wave. The majority of the studies in this review encompassed RAP metric analysis (n = 43), followed by Spiegelberg Compliance Monitor (n = 11), TCD studies (n = 9), studies on the HFC/HHC (n = 5), and studies on the P2/P1 ratio studies (n = 6). These studies predominantly involved acute traumatic neural injury (i.e. Traumatic Brain Injury) patients and those with hydrocephalus. RAP is the most extensively studied of the five focused methods and exhibits diverse applications. However, most papers lack clarification on its clinical applicability, a circumstance that is similarly observed for the other methods. Significance. Future directions involve exploring RAP patterns and identifying characteristics and artifacts, investigating neuroimaging correlations with continuous CC/CCR and integrating machine learning, holding promise for simplifying CC/CCR determination. These approaches should aim to enhance the precision and accuracy of the metric, making it applicable in clinical practice.

14 December 2023 in Intensive Care Medicine Experimental
Verified
Journal Article
Open access
PDF file
KSKevin Y Stein
Kevin Y Stein
LFLogan Froese
Logan Froese
AGAlwyn Gomez
Alwyn Gomez
ASAmanjyot Singh Sainbhi
Amanjyot Singh Sainbhi
NVNuray Vakitbilir
Nuray Vakitbilir
FZFrederick Zeiler
Frederick Zeiler
Background: Optimal cerebral perfusion pressure (CPPopt) has emerged as a promising personalized medicine approach to the management of moderate-to-severe traumatic brain injury (TBI). Though literature demonstrating its association with poor outcomes exists, there is yet to be work done on its association with outcome transition due to a lack of serial outcome data analysis. In this study we investigate the association between various metrics of CPPopt and failure to improve in outcome over time.Methods: CPPopt was derived using three different cerebrovascular reactivity indices; the pressure reactivity index (PRx), the pulse amplitude index (PAx), and the RAC index. For each index, % times spent with cerebral perfusion pressure (CPP) above and below its CPPopt and upper and lower limits of reactivity were calculated. Patients were dichotomized based on improvement in Glasgow Outcome Scale-Extended (GOSE) scores intoImprovedvs.Not Improvedbetween 1 and 3 months, 3 and 6 months, and 1- and 6-month post-TBI. Logistic regression analyses were then conducted, adjusting for the International Mission for Prognosis and Analysis of Clinical Trials (IMPACT) variables.Results: This study included a total of 103 patients from the Winnipeg Acute TBI Database. Through Mann–WhitneyUtesting and logistic regression analysis, it was found that % time spent with CPP below CPPopt was associated with failure to improve in outcome, while % time spent with CPP above CPPopt was generally associated with improvement in outcome.Conclusions: Our study supports the existing narrative that time spent with CPP below CPPopt results in poorer outcomes. However, it also suggests that time spent above CPPopt may not be associated with worse outcomes and is possibly even associated with improvement in outcome.

13 January 2024 in Sensors
Verified
Journal Article
Open access
PDF file
AGAlwyn Gomez
Alwyn Gomez
LFLogan Froese
Logan Froese
TBTobias Joshua Gordon Bergmann
Tobias Joshua Gordon Bergmann
ASAmanjyot Singh Sainbhi
Amanjyot Singh Sainbhi
NVNuray Vakitbilir
Nuray Vakitbilir
FZFrederick Zeiler
Frederick Zeiler
The contemporary monitoring of cerebrovascular reactivity (CVR) relies on invasive intracranial pressure (ICP) monitoring which limits its application. Interest is shifting towards near-infrared spectroscopic regional cerebral oxygen saturation (rSO2)-based indices of CVR which are less invasive and have improved spatial resolution. This study aims to examine and model the relationship between ICP and rSO2-based indices of CVR. Through a retrospective cohort study of prospectively collected physiologic data in moderate to severe traumatic brain injury (TBI) patients, linear mixed effects modeling techniques, augmented with time-series analysis, were utilized to evaluate the ability of rSO2-based indices of CVR to model ICP-based indices. It was found that rSO2-based indices of CVR had a statistically significant linear relationship with ICP-based indices, even when the hierarchical and autocorrelative nature of the data was accounted for. This strengthens the body of literature indicating the validity of rSO2-based indices of CVR and potential greatly expands the scope of CVR monitoring.

28 February 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
ASAmanjyot Singh Sainbhi
Amanjyot Singh Sainbhi
LFLogan Froese
Logan Froese
KSKevin Y Stein
Kevin Y Stein
NVNuray Vakitbilir
Nuray Vakitbilir
AGAlwyn Gomez
Alwyn Gomez
FZFrederick Zeiler
Frederick Zeiler
Continuous metrics of cerebral autoregulation (CA) assessment have been developed using various multimodal cerebral physiological monitoring devices. However, CA regional disparity remains unclear in states of health and disease. Leveraging existing archived data sources, we preliminarily evaluated regional hemispheric disparity in CA using the near infrared spectroscopy (NIRS)-derived cerebral oximetry index (COx/COx-a). Along with bilateral NIRS, regional cerebral oxygen saturation, arterial blood pressure, cerebral perfusion pressure, and bilateral COx/COx-a were derived using three different temporal resolutions—10 s, 1 min, and 5 min—based on non-overlapping mean values. The regional disparity between hemispheres was evaluated based on median and median absolute deviation. Further, patient-level autoregressive integrative moving average models were calculated for each signal stream and used to generate personalized vector autoregressive models. Multi-variate cerebral physiologic relationships between hemispheres were assessed via impulse response functions and Granger causality analyses. Data from 102 healthy control volunteers, 27 spinal surgery patients, and 95 TBI patients (varying in frontal lobe pathology impacting the optode path; 64 without bifrontal lobe pathology, 15 without left frontal lobe pathology, 11 without right frontal lobe pathology, and 5 with bifrontal lobe pathology) were retrospectively analyzed. For subjects with or without cranial pathology, no difference in COx/COx-a was found between hemispheres regardless of the analytic method. In TBI patients without pathology underneath the NIRS sensor, distant parenchymal injury does not seem to have an effect on the CA of uninjured frontal lobes. Further work is required to characterize regional disparities with multi-channel CA measurements in healthy and disease states.