Michael Kocybik

Mr. Michael Kocybik

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 September 2023 in Laser & Photonics Reviews
Verified
Journal Article
Open access
SMShiva Mohammadzadeh
Shiva Mohammadzadeh
AKAndreas Keil
Andreas Keil
MKMichael Kocybik
Michael Kocybik
LSLauri Maximilian Schwenson
Lauri Maximilian Schwenson
LLLars Liebermeister
Lars Liebermeister
Fabian FriederichFabian Friederich
Fabian Friederich
A novel photonic terahertz measurement system based on a frequency‐modulated continuous‐wave (FMCW) radar approach is presented. In previous works, fast frequency modulation has been demonstrated in connection with a continuous wave terahertz spectroscopy setup based on the photomixing principle. In this paper, a terahertz radar based on both a photomixing transmitter and a photomixing receiver, in contrast to the rigid spectroscopy approach, is reported. Hereby, frequency modulation bandwidths of more than 1.65 THz in radar operation is achieved. This corresponds to an order of magnitude more than what is previously achieved by terahertz radar systems. At the same time, measurement rates can be achieved that are comparable with radar systems based on Monolithic Microwave Integrated Circuits (MMICs) according to the current state of the art. Within the scope of the work, two operating modes are realized, one with a measurement rate of about 560 Hz at 600 GHz modulation bandwidth and one with 200 Hz at 1.65 THz modulation bandwidth, which can be set within the spectrum from 50 GHz to about 4.5 THz. The possibility to adjust the operating range of the radar without necessary hardware adaptations is another unique feature of the presented system, which allows the operator to choose a suitable frequency band that corresponds best to a certain measurement scheme via software settings. Besides the potential for multi‐layer thickness inspections, the capabilities of this technique for terahertz imaging applications are presented.

6 March 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MKMichael Kocybik
Michael Kocybik
MBMaris Bauer
Maris Bauer
FFFabian Friederich
Fabian Friederich
We present observations of parasitic frequency components in the emission spectrum of typical photomixer sources for continuous wave (CW) terahertz generation. Broadband tunable photomixer systems are often used in combination with direct power detectors, e.g., for source and/or detector characterization. Here, spectral components besides the intended terahertz emission at the difference frequency of the two excitation lasers can significantly distort the measurement results. In this work, the appearance of parasitic mixing signals is observed in broadband measurements with a broadband antenna-coupled field-effect transistor as terahertz detector (TeraFET). The measurements reveal weaker spectral absorption features than expected and also a signal plateau towards higher frequencies, both strongly indicating a background in the detection signals. The photomixer emission is investigated in detail with a terahertz Fourier-transform infrared spectrometer (FTIR). We relate the observed parasitic frequency components with good quantitative agreement with the mode spectra of the semiconductor lasers. We also present one possible approach to overcome some of the issues, and we emphasize the importance of our findings to avoid distorted measurement results. To our knowledge, the essential aspect of parasitic mixing has so far been largely ignored in the literature where terahertz CW photomixer emitters are widely used for spectrally resolved measurements.

8 August 2023 in IEEE Transactions on Terahertz Science and Technology
Verified
Journal Article
Open access
ATAlexander Theis
Alexander Theis
MKMichael Kocybik
Michael Kocybik
GFGeorg von Freymann
Georg von Freymann
Fabian FriederichFabian Friederich
Fabian Friederich
We present an optoelectronic hybrid system to perform high-resolution spectrum analysis in the terahertz regime. The concept is based on phase-locking of the difference frequencies of at least three continuous-wave (CW) distributed-feedback diode lasers by mixing the laser light with the radiation from a high-power electronic narrow-band source. Unlike for state-of-the-art spectrum analysis, no additional frequency extenders are required, keeping the system less complex and more cost-effective. Following our concept, we can generate laser difference frequencies from 0 to more than 1 THz with several Hz precision, which can be easily expanded to even higher frequencies, e.g., by cascading more lasers within our synchronization scheme. We demonstrate the systems frequency resolution and stability by measuring the first five harmonics of an electronic W-band source, and the first three of an active multiplier chain millimeter-wave source, using a CW GaAs photoconductive antenna as a receiver.

18 March 2025 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Open access
ATAlexander Theis
Alexander Theis
MKMichael Kocybik
Michael Kocybik
Maris BauerMaris Bauer
Maris Bauer
GFGeorg von Freymann
Georg von Freymann
Fabian FriederichFabian Friederich
Fabian Friederich
We present a photonic ultrawideband frequency extension for a commercial vector network analyzer (VNA) to perform free-space measurements in a frequency range from 70 to 520 GHz with a hertz level resolution. The concept is based on the synchronization of continuous-wave (CW) lasers with highly frequency-stable electronic emitter sources as a reference. The use of CW photomixers with bandwidths up to several terahertz (THz) allows for the straightforward expansion of the covered frequency range to 1 THz or even beyond. This can be achieved, for instance, by cascading additional lasers within the synchronization scheme. Consequently, the necessity for additional frequency extender modules, as seen in current state-of-the-art VNAs, is eliminated, thereby reducing the complexity and cost of the system significantly. To showcase the capabilities of the photonic vector network analyzer (PVNA) extender concept, we conducted S21 transmission measurements of various cross-shaped bandpass filters and waveguide-coupled high-frequency (HF) components. In addition, the analyzed magnitude and phase data were either compared to electromagnetic (EM) simulations or referenced against data obtained from commercial electronic frequency extender modules.