Christina Frölich Frandsen

Dr. Christina Frölich Frandsen


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 December 2021 in European Geriatric Medicine
Verified
Journal Article
Closed access
PDF file
CFChristina Frölich Frandsen
Christina Frölich Frandsen
EGEva Natalia Glassou
Eva Natalia Glassou
MSMaiken Stilling
Maiken Stilling
THTorben Baek Hansen
Torben Baek Hansen

12 May 2021 in Acta Orthopaedica
Verified
Journal Article
Open access
PDF file
CFChristina Frölich Frandsen
Christina Frölich Frandsen
EGEva N Glassou
Eva N Glassou
MSMaiken Stilling
Maiken Stilling
THTorben B Hansen
Torben B Hansen
Background and purpose — Following a hip fracture, most patients will encounter poorer functional outcomes and an increased risk of death. Treatment-monitoring of hip frac- ture patients is in many countries done by national audits. However, they do not allow for a deeper understanding of treatment limitations. We performed a local evaluation study to investigate adherence to 7 best-practice indicators, and to investigate patient groups at risk of suboptimal treatment. Patients and methods — 2,804 patients were surgically treated for a hip fracture from 2011 to 2017 at our institution. Data regarding admission, hospital stay, and discharge was prospectively collected, and adherence to the 7 best practice indicators (nerve block, surgical delay, antibiotics, implant choice, thromboprophylaxis, mobilization, and blood trans- fusions) was analyzed. Patient groups with lower adherence were identified. Results — 34% of patients received all 7 best practice indicators after considering contraindications; in particular, nerve blocks and thromboprophylaxis displayed low adher- ence at 61% and 91% respectively. Nursing home residents and patients with cognitive impairment, multiple comorbidi- ties, or low functional levels were at risk of having a lower adherence. Interpretation — The most dependent patients with cog- nitive impairment, comorbidities, or low functional levels had lower guideline adherence. This large patient subgroup needs a higher treatment focus and more resources. Our find- ings are likely similar to those in other national and interna- tional institutions.

Verified
Journal Article
Open access
PDF file
CFChristina Frölich Frandsen
Christina Frölich Frandsen
THTorben Bæk Hansen
Torben Bæk Hansen
Adverse reactions to metal-on-metal (MoM) prostheses are well known from total hip joint resurfacing arthroplasty with elevated serum chrome or cobalt, pain and pseudo tumor formation. It may, however, also be seen after total joint replacement of the trapeziometacarpal joint using MoM articulation, and we present two cases of failure of MoM prostheses due to elevated metal-serum levels in one case and pseudo tumor formation in another case. Furthermore, we suggest a diagnostic algorithm for joint pain after MoM trapeziometacarpal joint replacement based on published experiences from MoM hip prostheses and adverse reactions to metal.

1 March 2018 in HIP International
Verified
Journal Article
Closed access
STSteffan Tabori-Jensen
Steffan Tabori-Jensen
CFChristina Frölich Frandsen
Christina Frölich Frandsen
THTorben Bæk Hansen
Torben Bæk Hansen
SBSøren Bøvling
Søren Bøvling
MHMorten Homilius
Morten Homilius
Maiken StillingMaiken Stilling
Maiken Stilling
Introduction: Dual mobility (DM) total hip arthroplasty (THA) may reduce dislocation risk, but might increase the risk of high polyethylene (PE) wear due to double wearing surfaces. Methods: 127 patients (97 female) with 129 hips operated with THA after displaced femoral neck fracture FNF between 2005 and 2011, were seen for a cross-sectional clinical follow-up. Acetabular components were Saturne® DM cups with 28mm chrome-cobalt heads in UHMWPE. Cementless cups (n = 73) were hydroxyapatite coated. Radiographs were obtained for analysis of cup placement, 2D polyethylene wear and wear-rate (PolyWare 3D), and further radiological evaluation. Activity measurements included Timed Up and Go test (TUG) and walking distance from Harris Hip Score (HHS). Results: At a mean follow-up of 2.83 (1.0-7.7) years the mean wear was 0.82 mm (range 0.17-4.51, SD 0.50), and the wear-rate was 0.37 mm (range 0.06-1.90, SD 0.29). Wear-rate of 0.43 mm/year (SD 0.30) in cementless cups was higher (p = 0.004) than 0.30 mm/year (SD 0.27) in cemented cups. Mean age at time of surgery was 75.1 years (range 30-95). There was no correlation between age at time of surgery and wear (p = 0.56). There was no correlation between cup inclination and wear-rate (p = 0.35). TUG was mean 13.4 seconds (range 4.5-30.1) and correlated with wear rate (p = 0.03). Conclusions: At short term follow-up, the mean wear-rate in old and low demand patients was high, correlated to activity, and was above the generally accepted osteolysis threshold (0.1 mm/yr.). Cementless HA-coated cups had higher wear-rate than cemented cups.

8 January 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
CFChristina Frölich Frandsen
Christina Frölich Frandsen
EMElisabeth Mechlenburg Møller
Elisabeth Mechlenburg Møller
SBSara Birch
Sara Birch
LLLone Lundager
Lone Lundager
THTorben Bæk Hansen
Torben Bæk Hansen
Maiken StillingMaiken Stilling
Maiken Stilling
Patients sustaining a hip fracture experience reduced function and an increased risk of recurrent falls and institutionalization following surgical treatment. Rehabilitation programs that are feasible for home-based training could improve patient-reported outcomes and physical function while lowering the care need and social dependency of this patient group. In the present study, we designed and tested a home-based resistance training program on a group of patients with a femoral neck fracture (FNF) selected according to their poor post-operative functional recovery following an FNF. The results showed that the training program was feasible to perform for the patients, and after three months of training, the patients’ walking, physical activity, and patient-reported outcome measures improved. The patients were encouraged to continue walking and performing the training program, but twelve months after the FNF, the results were comparable to the baseline. Background: Femoral neck fracture (FNF) is associated with reduced function, often leading to an increased care need and a greater risk of recurrent falls. Thus, rehabilitation should be a priority. The present study investigated the training potential among fragile FNF patients with poor functional performance treated with total hip arthroplasty. Methods: In a prospective cohort study, 32 participants were included based on poor functional recovery following an FNF fracture. The participants completed a three-month, physiotherapy-guided, home-based resistance training program. At the baseline and three-month follow-up, physiotherapists performed functional tests and measured spatiotemporal parameters, muscle strength, and muscle mass. The Oxford hip score (OHS) questionnaire was administered and physical activity measurements were performed at baseline and at three-month and 12-month follow-ups. Results: Walking distance, step length, walking speed, and muscle strength increased at the three-month follow-up (p < 0.05). OHS scores increased from the baseline to the 12-month follow-up. Physical activity after three months showed more time spent standing (p = 0.02) and walks of 5–10 min (p = 0.002) compared to the baseline. At the 12-month follow-up, physical activity was similar to the baseline. Conclusions: Fragile patients with low functional performance following FNF displayed training potential with an improvement in function, strength, and physical activity. However, continued training is necessary in order to maintain the positive effects.

25 October 2022 in European Geriatric Medicine
Verified
Journal Article
Closed access
PDF file
CFChristina Frölich Frandsen
Christina Frölich Frandsen
MSMaiken Stilling
Maiken Stilling
EGEva Natalia Glassou
Eva Natalia Glassou
APAnne Birgitte Langsted Pedersen
Anne Birgitte Langsted Pedersen
THTorben Baek Hansen
Torben Baek Hansen