Nowadays, many aircraft manufacturers are working on new airplanes to reduce the environmental footprint and therefore meet greenhouse gas reduction targets. The concept of more electric aircraft is one of the solutions to achieve this goal. For this aircraft architecture, several electrical devices are used in order to supply propulsive and non-propulsive functions. This paper focuses on the sizing of a direct hybridization system to supply a non-propulsive function in an aircraft. It is composed of a High-Temperature Proton Exchange Membrane Fuel Cell (HT-PEMFC) and a lithium-ion (Li-ion) battery. This sizing is based on a static model of each storage device. The accuracy of these models is compared with dynamic models during a simulation for an aeronautical mission. Static models are implemented in a genetic algorithm to achieve two goals: on the one hand, satisfy the mission profile, and on the other hand, minimize the mass of the system. Other criteria, such as battery and fuel cell aging estimation, are considered. The obtained results show that the direct hybridization system allows protecting the fuel cell against an accelerated aging.
12 January 2023 in International Journal of Hydrogen Energy
Purpose: A wide number of applications requires classifying or grouping data into a set of categories or clusters. The most popular clustering techniques to achieve this objective are K‐means clustering and hierarchical clustering. However, both of these methods necessitate the a priori setting of the cluster number. The purpose of this paper is to present a clustering method based on the use of a niching genetic algorithm to overcome this problem.Design/methodology/approach: The proposed approach aims at finding the best compromise between the inter‐cluster distance maximization and the intra‐cluster distance minimization through the silhouette index optimization. It is capable of investigating in parallel multiple cluster configurations without requiring any assumption about the cluster number.Findings: The effectiveness of the proposed approach is demonstrated on 2D benchmarks with non‐overlapping and overlapping clusters.Originality/value: The proposed approach is also applied to the clustering analysis of railway driving profiles in the context of hybrid supply design. Such a method can help designers to identify different system configurations in compliance with the corresponding clusters: it may guide suppliers towards “market segmentation”, not only fulfilling economic constraints but also technical design objectives.
The operating conditions can have uncontrolled effects on the voltage of a High-Temperature Proton Exchange Membrane Fuel Cell (HT-PEMFC). For instance, the HT-PEMFC can be used at ambient pressure, i.e., without having a back pressure regulator. In this case, the variation in the atmospheric pressure directly affects pressures inside the fuel cell, which induces voltage variation. Moreover, in transient phases, several coupled phenomena can have an uncontrolled effect on the voltage. For example, following a change in the current operating point, thermal conditions in the fuel cell can vary, and the temperature stabilization then leads to a voltage variation. This article introduces a readjustment method for the fuel cell voltage to compensate for the effects of the pressure and temperature variations that are undergone and to decouple their effects. This methodology is based on the realization of a design of experiments to characterize the voltage sensitivity to pressure ([1; 1.5 bar]) and temperature ([120; 180 °C]) between 0.2 and 1 A/cm2 of an Advent PBI MEA (formerly BASF Celtec®-P 1100 W). The data obtained allowed identifying an empirical model that takes into account the aging caused by the experiment. Finally, the methodology is criticized before proposing an alternative method.
In this work, a commercially available membrane electrode assembly from Advent Technology Inc., developed for use in high-temperature proton exchange membrane fuel cells, was tested under various operating conditions (OCs) according to a sensibility study with three OCs varying on three levels: hydrogen gas over-stoichiometry (1.05, 1.2, 1.35), air gas over-stoichiometry (1.5, 2, 2.5), and temperature (140 °C, 160 °C, 180 °C). A polarization curve (V-I curve) was performed for each set of operating conditions (27 V-I curves in total). A semi-empirical and macroscopic (0D) model of the cell voltage was developed in steady-state conditions to model these experimental data. With the proposed parameterization approach, only one set of parameters is used in order to model all the experimental curves (simultaneous optimization with 27 curves). Thus, an air over-stoichiometry-dependent model was developed. The obtained results are promising between 0.2 and 0.8 A·cm−2: an average error less than 1.5% and a maximum error around 7% between modeled and measured voltages with only 9 parameters to identify. The obtained parameters appear consistent, regardless of the OCs. The proposed approach with only one set of parameters seems to be an interesting way to converge towards the uniqueness of consistent parameters.