Sylvain Rigal

Dr. Sylvain Rigal

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 January 2023 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
MBMathieu Baudy
Mathieu Baudy
AJAmine Jaafar
Amine Jaafar
CTChristophe Turpin
Christophe Turpin
SASofyane Abbou
Sofyane Abbou
SRSylvain Rigal
Sylvain Rigal

24 January 2024 in Energies
Verified
Journal Article
Open access
PDF file
SRSylvain Rigal
Sylvain Rigal
AJAmine Jaafar
Amine Jaafar
CTChristophe Turpin
Christophe Turpin
THThéophile Hordé
Théophile Hordé
JJJean-Baptiste Jollys
Jean-Baptiste Jollys
PKPaul Kreczanik
Paul Kreczanik
In this work, a commercially available membrane electrode assembly from Advent Technology Inc., developed for use in high-temperature proton exchange membrane fuel cells, was tested under various operating conditions (OCs) according to a sensibility study with three OCs varying on three levels: hydrogen gas over-stoichiometry (1.05, 1.2, 1.35), air gas over-stoichiometry (1.5, 2, 2.5), and temperature (140 °C, 160 °C, 180 °C). A polarization curve (V-I curve) was performed for each set of operating conditions (27 V-I curves in total). A semi-empirical and macroscopic (0D) model of the cell voltage was developed in steady-state conditions to model these experimental data. With the proposed parameterization approach, only one set of parameters is used in order to model all the experimental curves (simultaneous optimization with 27 curves). Thus, an air over-stoichiometry-dependent model was developed. The obtained results are promising between 0.2 and 0.8 A·cm−2: an average error less than 1.5% and a maximum error around 7% between modeled and measured voltages with only 9 parameters to identify. The obtained parameters appear consistent, regardless of the OCs. The proposed approach with only one set of parameters seems to be an interesting way to converge towards the uniqueness of consistent parameters.

18 June 2024 in Energies
Verified
Journal Article
Open access
PDF file
SRSylvain Rigal
Sylvain Rigal
AJAmine Jaafar
Amine Jaafar
CTChristophe Turpin
Christophe Turpin
THThéophile Hordé
Théophile Hordé
JJJean-Baptiste Jollys
Jean-Baptiste Jollys
PKPaul Kreczanik
Paul Kreczanik
In this work, three commercially available Membrane Electrode Assemblies (MEAs) from Advent Technology Inc. and Danish Power Systems, developed for a use in High Temperature Proton Exchange Membrane Fuel Cell (HT-PEMFC), were tested under various Operating Conditions (OCs): over-stoichiometry of hydrogen gas (1.05, 1.2, 1.35), over-stoichiometry of air gas (1.5, 2, 2.5), gas oxidant (O2 or air) and temperature (140 °C, 160 °C, 180 °C). For each set of operating conditions, a polarization curve (V–I curve) was performed. A semi-empirical and macroscopic (0D) model of the fuel cell voltage was established in steady state conditions in order to model some of these experimental data. The proposed parameterization approach for this model (called here the “multi-VI” approach) is based on the sensitivity to the operating conditions specific to each involved physicochemical phenomenon. According to this method, only one set of parameters is used in order to model all the experimental curves (optimization is performed simultaneously on all curves). A model depending on air over-stoichiometry was developed. The main objective is to validate a simple (0D) and fast-running model that considers the impact of air over-stoichiometry on cell voltage regarding all commercially available MEAs. The obtained results are satisfying with AdventPBI MEA and Danish Power Systems MEA: an average error less than 1.5% and a maximum error around 15% between modelled and measured voltages with only nine parameters to identify. However, the model was not as adapted to Advent TPS® MEA: average error and maximum error around 4% and 21%, respectively. Most of the obtained parameters appear consistent regardless of the OCs. The predictability of the model was also validated in the explored domain during the sensibility study with an interesting accuracy for 27 OCs after being trained on only nine curves. This is attractive for industrial application, since it reduces the number of experiments, hence the cost of model development, and is potentially applicable to all commercial HT-PEMFC MEAs.

4 December 2024 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
MBMathieu Baudy
Mathieu Baudy
SRSylvain Rigal
Sylvain Rigal
AEAntoine Escande
Antoine Escande
MGMélanie Grignon
Mélanie Grignon
SASofyane Abbou
Sofyane Abbou
CTChristophe Turpin
Christophe Turpin

5 July 2022 in TechRxiv
Verified
Preprint
Open access
PDF file
SRSylvain Rigal
Sylvain Rigal
Research paper. Abstract : In this work, a commercially available Membrane Electrode Assembly from Advent Technology Inc., developed for a use in High Temperature Proton Exchange Membrane Fuel Cell, was tested under various Operating Conditions (OCs) according to a sensibility study with three OCs varying on three levels: hydrogen gas over-stoichiometry (1.05, 1.2, 1.35), air gas over-stoichiometry (1.5, 2, 2.5) and temperature (140°C, 160°C, 180°C). A polarization curve (V-I curve) was performed for each set of operating conditions (27 V-I curves in total). A semi-empirical and macroscopic (1D) model of the cell voltage was developed in steady state conditions to model these experimental data. With the proposed parameterization approach, only one set of parameters is used in order to model all the experimental curves (simultaneous optimization with 27 curves). Thus, an air over-stoichiometry dependent model was developed. The obtained results are satisfying between 0.2 and 0.8 A.cm-²: an average error less than 1.5 % and a maximum error around 7 % between modelled and measured voltages with only 9 parameters to identify. The obtained parameters appear consistent regardless the OCs. The proposed approach with only one set of parameters seems to be an interesting way to converge towards a uniqueness of consistent parameters.