In the present study, we demonstrate atomic force microscopy (AFM)-based detection of hepatitis C virus (HCV) particles in serum samples using a chip with aptamer-functionalized surface (apta-based AFM chip). The target particles, containing core antigen of HCV (HCVcoreAg protein), were biospecifically captured onto the chip surface from 1 mL of test solution containing 10 µL of serum collected from a hepatitis C patient. The registration of aptamer/antigen complexes on the chip surface was performed by AFM. The aptamers used in the present study were initially developed for therapeutic purposes; herein, these aptamers have been successfully utilized as probe molecules for HCVcoreAg detection in the presence of a complex protein matrix (human serum). The results obtained herein can be used for the development of detection systems that employ affine enrichment for protein detection.
Herein, we have demonstrated highly sensitive real-time biospecific detection of a protein marker of hepatitis C—the core antigen of hepatitis C virus (HCVcoreAg)—using a nanowire (NW) biosensor. The primary element of the NW-biosensor is a chip with p-type conductance, bearing silicon-on-insulator (SOI) nanowire structures on its surface. The nanowire structures are fabricated by gas-plasma treatment and electron beam lithography. The detection specificity was provided by sensitization of the sensor surface with aptamers against HCVcoreAg. The influence of buffer pH on the sensor response signal was studied. The effect of reverse polarity of the biosensor response signal with change from the acidic buffer pH to the neutral one was found. The lowest detectable HCVcoreAg concentration was determined to be 2.0 × 10−15 M in both acidic (pH 5.1) and neutral (pH 7.4) buffer solution. The proposed aptamer-sensitized sensor was also successfully applied to detect HCVcoreAg in serum samples of hepatitis C patients.
12 March 2013 in Biochemistry (Moscow), Supplement Series B: Biomedical Chemistry
The atomic-force microscopy-based method of irreversible chemical AFM-fishing (AFM-IFchem) has been developed for the detection of proteins existing at ultra-low concentrations in solution. Using this method, a very low concentration of horseradish peroxidase (HRP) protein (10−17 M) was detected in solution. A theoretical model that allows the description of obtained experimental data has been proposed. This model takes into consideration both transport of the protein from the bulk solution onto the AFM-chip sur-face and its irreversible binding to the activated area.
Nanoribbon chips, based on “silicon-on-insulator” structures (SOI-NR chips), have been fabricated. These SOI-NR chips, whose surface was sensitized with covalently immobilized oligonucleotide molecular probes (oDNA probes), have been employed for the nanoribbon biosensor-based detection of a circular ribonucleic acid (circRNA) molecular marker of glioma in humans. The nucleotide sequence of the oDNA probes was complimentary to the sequence of the target oDNA. The latter represents a synthetic analogue of a glioma marker—NFIX circular RNA. In this way, the detection of target oDNA molecules in a pure buffer has been performed. The lowest concentration of the target biomolecules, detectable in our experiments, was of the order of ~10−17 M. The SOI-NR sensor chips proposed herein have allowed us to reveal an elevated level of the NFIX circular RNA in the blood of a glioma patient.
Atomic force microscopy (AFM)-based fishing is a promising method for the detection of low-abundant proteins. This method is based on the capturing of the target proteins from the analyzed solution onto a solid substrate, with subsequent counting of the captured protein molecules on the substrate surface by AFM. Protein adsorption onto the substrate surface represents one of the key factors determining the capturing efficiency. Accordingly, studying the factors influencing the protein adsorbability onto the substrate surface represents an actual direction in biomedical research. Herein, the influence of water motion in a flow-based system on the protein adsorbability and on its enzymatic activity has been studied with an example of horseradish peroxidase (HRP) enzyme by AFM, attenuated total reflection Fourier-transform infrared spectroscopy (ATR-FTIR) and conventional spectrophotometry. In the experiments, HRP solution was incubated in a setup modeling the flow section of a biosensor communication. The measuring cell with the protein solution was placed near a coiled silicone pipe, through which water was pumped. The adsorbability of the protein onto the surface of the mica substrate has been studied by AFM. It has been demonstrated that incubation of the HRP solution near the coiled silicone pipe with flowing water leads to an increase in its adsorbability onto mica. This is accompanied by a change in the enzyme’s secondary structure, as has been revealed by ATR-FTIR. At the same time, its enzymatic activity remains unchanged. The results reported herein can be useful in the development of models describing the influence of liquid flow on the properties of enzymes and other proteins. The latter is particularly important for the development of biosensors for biomedical applications—particularly for serological analysis, which is intended for the early diagnosis of various types of cancer and infectious diseases. Our results should also be taken into account in studies of the effects of protein aggregation on hemodynamics, which plays a key role in human body functioning.
The detection of CA 125 protein in a solution using a silicon-on-insulator (SOI)-nanowire biosensor with n-type chip has been experimentally demonstrated. The surface of nanowires was modified by covalent immobilization of antibodies against CA 125 in order to provide the biospecificity of the target protein detection. We have demonstrated that the biosensor signal, which results from the biospecific interaction between CA 125 and the covalently immobilized antibodies, increases with the increase in the protein concentration. At that, the minimum concentration, at which the target protein was detectable with the SOI-nanowire biosensor, amounted to 1.5 × 10−16 M.