Andrey Kozlov

Mr. Andrey Kozlov


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2020 in Coatings
Verified
Journal Article
Open access
PDF file
Kristina MalsagovaKristina Malsagova
Kristina Malsagova
TPTatyana Pleshakova
Tatyana Pleshakova
RGRafael A. Galiullin
Rafael A. Galiullin
ISIvan D. Shumov
Ivan D. Shumov
AKAndrey Kozlov
Andrey Kozlov
YIYuri D. Ivanov
Yuri D. Ivanov
Herein, we have demonstrated highly sensitive real-time biospecific detection of a protein marker of hepatitis C—the core antigen of hepatitis C virus (HCVcoreAg)—using a nanowire (NW) biosensor. The primary element of the NW-biosensor is a chip with p-type conductance, bearing silicon-on-insulator (SOI) nanowire structures on its surface. The nanowire structures are fabricated by gas-plasma treatment and electron beam lithography. The detection specificity was provided by sensitization of the sensor surface with aptamers against HCVcoreAg. The influence of buffer pH on the sensor response signal was studied. The effect of reverse polarity of the biosensor response signal with change from the acidic buffer pH to the neutral one was found. The lowest detectable HCVcoreAg concentration was determined to be 2.0 × 10−15 M in both acidic (pH 5.1) and neutral (pH 7.4) buffer solution. The proposed aptamer-sensitized sensor was also successfully applied to detect HCVcoreAg in serum samples of hepatitis C patients.

13 July 2021 in Biosensors
Verified
Journal Article
Open access
PDF file
YIYuri D. Ivanov
Yuri D. Ivanov
Kristina MalsagovaKristina Malsagova
Kristina Malsagova
VPVladimir Popov
Vladimir Popov
TPTatyana Pleshakova
Tatyana Pleshakova
AKAndrey Kozlov
Andrey Kozlov
AAAlexander Archakov
Alexander Archakov
Nanoribbon chips, based on “silicon-on-insulator” structures (SOI-NR chips), have been fabricated. These SOI-NR chips, whose surface was sensitized with covalently immobilized oligonucleotide molecular probes (oDNA probes), have been employed for the nanoribbon biosensor-based detection of a circular ribonucleic acid (circRNA) molecular marker of glioma in humans. The nucleotide sequence of the oDNA probes was complimentary to the sequence of the target oDNA. The latter represents a synthetic analogue of a glioma marker—NFIX circular RNA. In this way, the detection of target oDNA molecules in a pure buffer has been performed. The lowest concentration of the target biomolecules, detectable in our experiments, was of the order of ~10−17 M. The SOI-NR sensor chips proposed herein have allowed us to reveal an elevated level of the NFIX circular RNA in the blood of a glioma patient.

9 January 2021 in Molecules
Verified
Journal Article
Open access
PDF file
YIYuri D. Ivanov
Yuri D. Ivanov
TPTatyana Pleshakova
Tatyana Pleshakova
ISIvan D. Shumov
Ivan D. Shumov
AKAndrey Kozlov
Andrey Kozlov
AVAnastasia Valueva
Anastasia Valueva
VZVadim Ziborov
Vadim Ziborov
Atomic force microscopy (AFM)-based fishing is a promising method for the detection of low-abundant proteins. This method is based on the capturing of the target proteins from the analyzed solution onto a solid substrate, with subsequent counting of the captured protein molecules on the substrate surface by AFM. Protein adsorption onto the substrate surface represents one of the key factors determining the capturing efficiency. Accordingly, studying the factors influencing the protein adsorbability onto the substrate surface represents an actual direction in biomedical research. Herein, the influence of water motion in a flow-based system on the protein adsorbability and on its enzymatic activity has been studied with an example of horseradish peroxidase (HRP) enzyme by AFM, attenuated total reflection Fourier-transform infrared spectroscopy (ATR-FTIR) and conventional spectrophotometry. In the experiments, HRP solution was incubated in a setup modeling the flow section of a biosensor communication. The measuring cell with the protein solution was placed near a coiled silicone pipe, through which water was pumped. The adsorbability of the protein onto the surface of the mica substrate has been studied by AFM. It has been demonstrated that incubation of the HRP solution near the coiled silicone pipe with flowing water leads to an increase in its adsorbability onto mica. This is accompanied by a change in the enzyme’s secondary structure, as has been revealed by ATR-FTIR. At the same time, its enzymatic activity remains unchanged. The results reported herein can be useful in the development of models describing the influence of liquid flow on the properties of enzymes and other proteins. The latter is particularly important for the development of biosensors for biomedical applications—particularly for serological analysis, which is intended for the early diagnosis of various types of cancer and infectious diseases. Our results should also be taken into account in studies of the effects of protein aggregation on hemodynamics, which plays a key role in human body functioning.

30 June 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YIYuri D. Ivanov
Yuri D. Ivanov
TPTatyana Pleshakova
Tatyana Pleshakova
ISIvan D. Shumov
Ivan D. Shumov
AKAndrey Kozlov
Andrey Kozlov
TRTatiana Romanova
Tatiana Romanova
VZVadim Ziborov
Vadim Ziborov
The influence of liquid motion in flow-based systems on the aggregation state of an enzyme and on its enzymatic activity was studied, with horseradish peroxidase (HRP) as an example. Our experiments were carried out in a setup modeling the flow section of the biosensor communication with a measuring cell containing a protein solution. Studies were conducted for a biosensor measuring cell located along the axis of a spiral-moving liquid flow. The aggregation state of the protein was determined with an atomic force microscopy-based sensor (AFM sensor). It has been demonstrated that upon flowing of water through silicone biosensor communications, an increased aggregation of HRP protein was observed, but, at the same time, its enzymatic activity did not change. Our results obtained herein are useful in the development of models describing the influence of liquid flow in biosensor communications on the properties of enzymes and other proteins. This is particularly important for the development of serologic protein biosensors, which are beginning to be used for the early diagnosis of oncological diseases (such as brain cancer, prostate cancer, breast cancer etc.). The results obtained herein should also be taken into account when considering possible changes in hemodynamics due to increased protein aggregation.

18 December 2020 in Biosensors
Verified
Journal Article
Open access
PDF file
Kristina MalsagovaKristina Malsagova
Kristina Malsagova
TPTatyana Pleshakova
Tatyana Pleshakova
RGRafael A. Galiullin
Rafael A. Galiullin
AKAndrey Kozlov
Andrey Kozlov
ISIvan D. Shumov
Ivan D. Shumov
YIYuri D. Ivanov
Yuri D. Ivanov
The detection of CA 125 protein in a solution using a silicon-on-insulator (SOI)-nanowire biosensor with n-type chip has been experimentally demonstrated. The surface of nanowires was modified by covalent immobilization of antibodies against CA 125 in order to provide the biospecificity of the target protein detection. We have demonstrated that the biosensor signal, which results from the biospecific interaction between CA 125 and the covalently immobilized antibodies, increases with the increase in the protein concentration. At that, the minimum concentration, at which the target protein was detectable with the SOI-nanowire biosensor, amounted to 1.5 × 10−16 M.

2 October 2020 in Chemosensors
Verified
Journal Article
Open access
PDF file
Kristina MalsagovaKristina Malsagova
Kristina Malsagova
TPTatyana Pleshakova
Tatyana Pleshakova
RGRafael A. Galiullin
Rafael A. Galiullin
AKAndrey Kozlov
Andrey Kozlov
TRTatiana Romanova
Tatiana Romanova
YIYuri D. Ivanov
Yuri D. Ivanov
Herein, we report the development of a highly sensitive nanotechnology-based system—silicon-on-insulator nanowire biosensor for the revelation of microRNAs (miRNAs), associated with the development of glioma in the human. In this system, a sensor chip, bearing an array of silicon nanowire structures, is employed. The sensor chip is fabricated using a top-down technology. In our experiments reported herein, we demonstrated the detection of DNA oligonucleotide (oDNA), which represents a synthetic analogue of microRNA-363 associated with the development of glioma. To provide biospecific detection of the target oligonucleotides, the surface of the nanowire structures is modified with oligonucleotide probes; the latter are complementary to the target ones. The concentration limit of the target oligonucleotide detection, attained using our nanowire biosensor, is at the level of DL~10−17 M. The revelation of the elevated level of glioma-associated miRNA in plasma is also demonstrated.