The South-to-North Water Diversion Project has been in operation since 2014, directly benefiting more than 79 million people in China. Thus, its service life and long-term performance have gained much attention from scholars. To predict its life and performance, this study used the seepage/stress-damage coupling method. In addition, a seepage/stress-damage coupling theory was proposed and a finite element model of a deep excavated canal in the Xichuan Section of the South-to-North Water Diversion Project was established. The results showed that this canal subsided greatly in the first two years of operation, which can be confirmed by the monitoring data. It is predicted that, after 50 years of normal operation, the canal damage may start and spread from the water level, and reach 37.6%, but such damage will not affect its normal water delivery function. The purpose of this study is to provide guidance for the safe operation of the project.
This study investigates the complex load-bearing mechanism of the reinforced concrete tower of large wind turbines through a structural model test. MTS electro-hydraulic servo loading system was used to load two reinforced concrete tower models for the push-out test. The ultimate bearing capacity of the reinforced concrete tower was found to be 8.894 kN. The test findings revealed that the top of the tower is subjected to unilateral shear as the horizontal load increases. As a result, the concrete strain in the compression zone of the test piece increases to its highest level in the bottom plastic hinge area. The concrete in the compression zone is being crushed in the meantime. The reinforcement achieves its yield point and deforms within the range of plastic failure when subjected to extreme loads. The outcomes of this study serve as a foundation for the running of wind turbines in extreme conditions.
The spiral case structure is an essential part of a hydropower station. To accurately explore the joint load-bearing effect of the cushion-spiral case structure, a cushion-spiral case structure with a high HD value was selected, modeled, and analyzed in this study. The reliability of the model was verified through measured data. Given the contact relation between the spiral case and the cushion, the cushion laying range was used as the control parameter to investigate its impact on the joint bearing capacity of the structure. In addition, the concrete damage theory was introduced to probe the damage mechanism of the structure under assumed extreme working conditions. The steel spiral case bears most of the internal water pressure in the joint bearing system, and the bearing ratio of the surrounding concrete and reinforcement decreases with the increase in the cushion wrap angle. A 1.1–1.2 overload head is the main section that forms penetrating cracks. For the spiral case structure with a high HD value, a reasonable cushion can significantly reduce the damage level of the surrounding concrete and regulate the uneven lifting of the turbine pier and the shear strength of the stay ring. This study can provide reference points for the spiral case arrangement and range and the structural failure response under extreme working conditions.
The spiral case and its surrounding concrete (SCSC) constitute the core components of the hydropower station's structural system. As the main loadbearing body of the hydroelectric generating unit, the quality of concrete construction serves as a critical prerequisite for ensuring the safe and stable operation of both the unit and the overall structure. In this study, the temperature control and cooling parameters of the SCSC during the construction phase were determined through inversion using the Coati Optimization Algorithm (COA). The resulting parameters were subsequently validated by finite element simulation. The findings indicate that the water pipe cooling parameters obtained via COA effectively limit the adiabatic temperature rise induced by the hydration heat of concrete, thereby offering theoretical guidance and technical reference for the temperature control design of mass concrete.