The Concrete Damaged Plasticity (CDP) constitutive is introduced to study the dynamic failure mechanism and the law of damage development to the aqueduct structure during the seismic duration using a large-scale aqueduct structure from the South-to-North Water Division Project (SNWDP) as a research object. Incremental dynamic analysis (IDA) and multiple stripe analysis (MSA) seismic fragility methods are introduced. The spectral acceleration is used as the scale of ground motion record intensity measure (IM), and the aqueduct pier top offset ratio quantifies the limit of structural damage measure (DM). The aqueduct structure’s seismic fragility evaluation curves are constructed with indicators of different seismic intensity measures to depict the damage characteristics of aqueduct structures under different seismic intensities through probability. The results show that penetrating damage is most likely to occur on both sides of the pier cap and around the pier shaft in the event of a rare earthquake, followed by the top of the aqueduct body, which requires the greatest care during an earthquake. The results of two fragility analysis methodologies reveal that the fragility curves are very similar. The aqueduct structure’s first limit state level (LS1) is quite steep and near the vertical line, indicating that maintaining the excellent condition without damage in the seismic analysis will be challenging. Except for individual results, the overall fragility results are in good agreement, and the curve change rule is the same. The exceedance probability in the case of any ground motion record IM may be estimated using only two factors when using the MSA approach, and the computation efficiency is higher. The study of seismic fragility analysis methods in this paper can provide a reference for the seismic safety evaluation of aqueducts and similar structures.
The measured vibrational responses of the pumping station pipeline in the irrigation site were chosen to confirm the chaotic characteristics of the pumping station pipeline vibration and to determine the vibrational excitation that makes it chaotic. First, the chaotic properties of the pipeline vibration responses were investigated using a saturation correlation dimension and the maximum Lyapunov exponent. The vibration excitation with chaotic features was obtained using an improved variational mode decomposition (IVMD) method to examine the multi-time-scale chaotic characteristics of the pipeline vibration responses. The results show that the vibrational responses of each measuring point of the pipeline under different operating conditions have clear chaotic characteristics, where the chaotic characteristics of the axial points and bifurcated pipe points are relatively strong. The vibration of the operating conditions and measurement points affected by the unit’s operation and flow state change is further complicated. The intrinsic mode function (IMF) produces a low-dimensional chaotic attractor after the IVMD disrupts the vibration response. Still, the vibration excitation of the remaining components on behalf of the units does not have chaotic properties, implying that water pulsation excitation makes the pumping station pipeline vibrations chaotic. The vibration excitation caused by the unit’s operation covers the chaotic characteristics of the pipeline vibration and increases its uncertainty. The outcomes of this study provide a theoretical basis for further exploration of the vibration characteristics of pumping station pipelines, and a new method of chaos analysis is proposed.
This study investigates the complex load-bearing mechanism of the reinforced concrete tower of large wind turbines through a structural model test. MTS electro-hydraulic servo loading system was used to load two reinforced concrete tower models for the push-out test. The ultimate bearing capacity of the reinforced concrete tower was found to be 8.894 kN. The test findings revealed that the top of the tower is subjected to unilateral shear as the horizontal load increases. As a result, the concrete strain in the compression zone of the test piece increases to its highest level in the bottom plastic hinge area. The concrete in the compression zone is being crushed in the meantime. The reinforcement achieves its yield point and deforms within the range of plastic failure when subjected to extreme loads. The outcomes of this study serve as a foundation for the running of wind turbines in extreme conditions.
This paper studies Karman vortex shedding and water-level fluctuation in the inverted siphon structure of the Middle Route of the South-to-North Water Diversion Project (MR-SNWDP) in China. Field investigations and numerical simulations for the inverted siphon outlet were performed to explore the characteristics and hazards of the vortex. Numerical results were compared with measured data to verify the effectiveness and reliability of the model. Based on the model, it is found that the periodic water-level fluctuations caused by the Karman vortex street will not only excite surges to beat the gate but will also induce periodical force on the gate pier. Those will damage the building structure and affect the delivery capacity in the long-term operation. Based on this, countermeasures of altering different pier tail shapes are proposed to control vortex shedding, and the effect is noticeable. The study presents a hydraulic process for the inverted siphon outlet and provides a theoretical reference for water delivery safety of inverted siphons and similar structures in MR-SNWDP.