Motofumi Nakanishi

Mr. Motofumi Nakanishi

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 July 2018 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
MNMotofumi Nakanishi
Motofumi Nakanishi
SIShintaro Izumi
Shintaro Izumi
SNSho Nagayoshi
Sho Nagayoshi
HKHiroshi Kawaguchi
Hiroshi Kawaguchi
MYMasahiko Yoshimoto
Masahiko Yoshimoto
STShigeho Tanaka
Shigeho Tanaka
Herein, an algorithm that can be used in wearable health monitoring devices to estimate metabolic equivalents (METs) based on physical activity intensity data, particularly for certain activities in daily life that make MET estimation difficult. Energy expenditure data were obtained from 42 volunteers using indirect calorimetry, triaxial accelerations and heart rates. The proposed algorithm used the percentage of heart rate reserve (%HRR) and the acceleration signal from the wearable device to divide the data into a middle-intensity group and a high-intensity group (HIG). The two groups were defined in terms of estimated METs. Evaluation results revealed that the classification accuracy for both groups was higher than 91%. To further facilitate MET estimation, five multiple-regression models using different features were evaluated via leave-one-out cross-validation. Using this approach, all models showed significant improvements in mean absolute percentage error (MAPE) of METs in the HIG, which included stair ascent, and the maximum reduction in MAPE for HIG was 24% compared to the previous model (HJA-750), which demonstrated a 70.7% improvement ratio. The most suitable model for our purpose that utilized heart rate and filtered synthetic acceleration was selected and its estimation error trend was confirmed. For HIG, the MAPE recalculated by the most suitable model was 10.5%. The improvement ratio was 71.6% as compared to the previous model (HJA-750C). This result was almost identical to that obtained from leave-one-out cross-validation. This proposed algorithm revealed an improvement in estimation accuracy for activities in daily life; in particular, the results included estimated values associated with stair ascent, which has been a difficult activity to evaluate so far.

1 December 2016
Verified
Conference Paper
Closed access
MTMio Tsukahara
Mio Tsukahara
SIShintaro Izumi
Shintaro Izumi
MNMotofumi Nakanishi
Motofumi Nakanishi
HKHiroshi Kawaguchi
Hiroshi Kawaguchi
MYMasahiko Yoshimoto
Masahiko Yoshimoto
YFYoshikazu Fujimori
Yoshikazu Fujimori
This paper describes a low-power metabolic equivalents (METs) estimation method for monitoring physical activity. Long-term continuous METs monitoring can contribute to detection of non-communicable diseases. The proposed system consists of dedicated METs estimation hardware and a non-volatile CPU. A test is fabricated in a 130-nm CMOS with a ferroelectric capacitor process. Evaluation results show that the proposed system, which consists of the test chip and an accelerometer, requires about 15-μA on average.