Objectives: To compare the effectiveness and safety of balloon aortic valvuloplasty (BAV) performed with or without rapid ventricular pacing (RP).Background: BAV technique is poorly standardized.Methods: One hundred consecutive patients were randomly assigned 1:1 between BAV performed with or without RP. Exclusion criteria were an immediate indication for surgical or transcatheter aortic valve replacement, presentation in cardiogenic shock or pulmonary edema refractory to medical stabilization.Results: There were 51 patients in the BAV group performed with RP, 49 in the BAV group without RP (noRP). Procedural success (50% hemodynamic gradient reduction) was achieved in 37.3% and 55.1%, respectively (P = 0.16). Fewer people in the noRP group complained of poor tolerance to the procedure (16% vs 41%). The primary efficacy endpoint, a 50% reduction in the mean echocardiographic trans‐aortic gradient, was met in 21/49 patients in the noRP group compared to 20/51 in the RP (42.9% vs 39.2%; P = 0.84). No significant difference between the groups was observed in the primary safety endpoint, a 30‐day composite of death, myocardial infarction, stroke, acute aortic regurgitation, and BARC bleeding ≥3 (8.2% noRP vs 13.7%; P = 0.53). The noRP group required fewer bailout temporary pacemakers (P = 0.048) and had a lower incidence of moderate/severe renal function worsening (4.1% vs 17.6%; P = 0.052).Conclusions: Rapid ventricular pacing did not influence BAV efficacy or safety and tolerance was slightly worse.
Interventional cardiology procedures require full anticoagulation to prevent thrombus formation on catheters and devices with potential development of embolic complications. Bivalirudin, a short half-life direct thrombin inhibitor, has been largely used during percutaneous coronary interventions and represents the preferred alternative to heparin in patients with heparin-induced thrombocytopenia (HIT). However, few data are available about intraprocedural use of bivalirudin during transcatheter structural heart disease interventions. Activated clotting time (ACT) monitoring during bivalirudin infusion presents some limitations and it is not mandatory. We report a case of bivalirudin use in a patient with type-2 HIT during percutaneous mitral valve repair with the Mitraclip system (Abbott, Abbott Park, Illinois, United States). Despite use of standard bivalirudin dose (0.75 mg/kg bolus and 1.4 mg/kg/min infusion—reduced infusion rate was motivated by a glomerular filtration rate of 37 mL/min), the patient developed a large thrombus on the second clip during its orientation toward the mitral orifice. ACT was measured at that time and was suboptimal (240 seconds). The case was successfully managed with clip and thrombus retrieval, adjunctive 0.3 mg/kg bivalirudin bolus and increased infusion rate, and clip repositioning with ACT monitoring. This report makes the case for mandatory ACT checking and drug titration during high-risk catheter–based structural heart disease interventions, even when thromboprophylaxis is performed with bivalirudin. Additional coagulation tests may be useful to monitor bivalirudin response in similar cases.
Introduction: Due to the selective criteria and short-term follow-up of previous transcatheter aortic valve implantation (TAVI) trials, the coronary revascularization incidence after TAVI has been difficult to determine. This study investigated the epidemiology of coronary revascularization after surgical aortic valve replacement (SAVR) and TAVI in patients with severe aortic valve stenosis (AS), with and without coronary artery disease (CAD), in a mid-term follow-up, single-center, real-world setting. Methods: Between 2010 to 2020, 1486 patients with AS underwent SAVR or TAVI with balloon-expandable Edwards® transcatheter heart valves (THVs). Using hospital discharge records, we could estimate for each patient resident in Emilia Romagna the rate of ischemic events treated with percutaneous coronary intervention (PCI). A subgroup without CAD was also analyzed. Results: The 5-year overall survival was 78.2%. Freedom from PCI after AVR and TAVI at 5 years was 96.9% and 96.9%, respectively, with previous PCI as a predictor (HR 4.86, 95% CI 2.57–9.21 p < 0.001). The freedom from PCI curves were not significantly different. Conclusions: Notwithstanding the aged population, the revascularization incidence was only 2.4%, requiring further evaluation even in younger patients with longer follow-up. Despite the profile frame raise due to the evolution of Edwards® balloon-expandable THVs, PCI or coronarography feasibility were not compromised in our population.