JAMES WISKIN

Dr. JAMES WISKIN


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 May 2017 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Open access
JWJAMES WISKIN
JAMES WISKIN
DBD. T. Borup
D. T. Borup
EIE. Iuanow
E. Iuanow
JKJ. Klock
J. Klock
MLMark W. Lenox
Mark W. Lenox
We describe a novel 3-D ultrasound technology, the quantitative transmission ultrasound system and algorithm to image a pendent breast in a water bath. Quantitative accuracy is verified using phantoms. Morphological accuracy is verified using cadaveric breast and in vivo images, and spatial resolution is estimated. This paper generalizes an earlier 2-D algorithm to a full 3-D inversion algorithm and shows the importance of such a 3-D algorithm for artifact suppression as compared with the 2-D algorithm. The resultant high-resolution ultrasound images, along with quantitative information regarding tissue speed of sound/stiffness, provide a more accurate depiction of the breast anatomy and lesions, contributing to improved breast care.

24 February 2023 in Academic Radiology
Verified
Journal Article
Open access
JWJAMES WISKIN
JAMES WISKIN
BMBilal Malik
Bilal Malik
CRCathy Ruoff
Cathy Ruoff
NPNasser Pirshafiey
Nasser Pirshafiey
MLMark Lenox
Mark Lenox
JKJohn Klock
John Klock
To indicate that 3D low-frequency ultrasound tomography with 3D data acquisition (volography) is a safe, low-cost, high-resolution, whole-body meso-scale medical imaging modality that gives high-resolution quantitatively accurate clinically relevant images. We compare the speed of sound accuracy in various organs in situ. We validate our 3D ultrasound tomography images using MRI and gross section anatomy as ground truth in 10-day old piglets. Data acquisition is accomplished with the QT Scanner at ∼1 MHz center frequency, and array transceivers for reflection data @3.6 MHz. Images are generated with unique model-based 3D ultrasound tomography algorithms. In reflection, we use 3D refraction-corrected ray tracing to allow 360° compounding with sub-mm resolution. Four 10-12 day old pigs were anesthetized and whole-body images were acquired via low-frequency transmitted ultrasound and 3T MRI. Tissue values were within an average of 1.07% (0.5%) of the literature values. We also show the detailed correlation of our images with MRI images in axial, coronal, and sagittal views. Volography images of a piglet show high resolution and quantitative accuracy, showing more contrast &resolution than 3T MRI, including the kidney showing medulla, cortex and fibrous cover, and small intestines with ileal lumen detail visible. We establish that 3D ultrasound tomography (volography), yields high-resolution quantitatively accurate images whole-body images in presence of bone and air which are potentially clinically useful but have not appeared in the literature.

1 October 2019
Verified
Conference Paper
Closed access
JWJAMES WISKIN
JAMES WISKIN
BMBilal Malik
Bilal Malik
RNRajni Natesan
Rajni Natesan
DBDavid Borup
David Borup
NPNasser Pirshafiey
Nasser Pirshafiey
JKJohn Klock
John Klock
Encouraged by progress over the past 10 years in breast imaging, we have generalized 3D ultrasound transmission tomography (UST) to orthopaedic, whole body and clinical applications. We document quantitative breast density measurement, quantitative transmission tomography in the presence of bone and air, and tumor monitoring applications, indicating that 3D UST is a whole body imaging modality with clinical implications.

1 September 2021 in Journal of Urology
Verified
Journal Article
Closed access
CWCheyenne Williams
Cheyenne Williams
MDMichael Daneshvar
Michael Daneshvar
YWYixuan Wu
Yixuan Wu
JOJeunice Owens-Walton
Jeunice Owens-Walton
NYNitin Yerram
Nitin Yerram
PPPeter Pinto
Peter Pinto
INTRODUCTION AND OBJECTIVE:With recent developments, state-of-the-art ultrasound tomography (UT) is now able to provide submillimeter-resolution imaging for tissue characterization and malignancy d...

19 May 2024 in Tomography
Verified
Journal Article
Open access
PDF file
JWJAMES WISKIN
JAMES WISKIN
JKJohn Klock
John Klock
SLSusan Love
Susan Love
The aim of this study was to show for the first time that low-frequency 3D-transmitted ultrasound tomography (3D UT, volography) can differentiate breast tissue types using tissue properties, accurately measure glandular and ductal volumes in vivo, and measure variation over time. Data were collected for 400 QT breast scans on 24 women (ages 18–71), including four (4) postmenopausal subjects, 6–10 times over 2+ months of observation. The date of onset of menopause was noted, and the cases were further subdivided into three (3) classes: pre-, post-, and peri-menopausal. The ducts and glands were segmented using breast speed of sound, attenuation, and reflectivity images and followed over several menstrual cycles. The coefficient of variation (CoV) for glandular tissue in premenopausal women was significantly larger than for postmenopausal women, whereas this is not true for the ductal CoV. The glandular standard deviation (SD) is significantly larger in premenopausal women vs. postmenopausal women, whereas this is not true for ductal tissue. We conclude that ducts do not appreciably change over the menstrual cycle in either pre- or post-menopausal subjects, whereas glands change significantly over the cycle in pre-menopausal women, and 3D UT can differentiate ducts from glands in vivo.

30 September 2025 in Tomography
Verified
Journal Article
Open access
PDF file
MAMaria Lourdes Anzola
Maria Lourdes Anzola
DADavid Alberico
David Alberico
JYJoyce Yip
Joyce Yip
JWJAMES WISKIN
JAMES WISKIN
BMBilal Malik
Bilal Malik
GCGregory J Czarnota
Gregory J Czarnota
Breast cancer detection remains a significant challenge, with traditional mammography presenting barriers such as discomfort, radiation exposure, high false-positive rates, and financial burden. Moreover, younger women frequently fall outside routine mammographic screening guidelines, leaving critical gaps in early detection. Objectives: This study investigates the potential of quantitative transmission breast acoustic computed tomography scanner imaging (QT3D) as an innovative, non-invasive imaging modality for characterizing and evaluating breast masses. Methods: A comparative analysis between QT3D imaging and magnetic resonance imaging (MRI) was conducted in a cohort of patients with biopsy-proven benign or malignant breast lesions, comparing key metrics in quantifying breast masses for the purposes of breast mass characterization. Results: The findings in this study highlight its capability in identifying relatively small tumors, multiple lesions, satellite lesions, intraductal extensions, and calcifications, in addition to offering valuable diagnostic insights. Conclusions: This work is a first step toward studies essential for confirming its clinical feasibility, establishing its role in breast cancer tumor characterization, and potentially improving patient outcomes.