Maria Lourdes Anzola

Dr. Maria Lourdes Anzola

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 May 2024 in PLOS Medicine
Verified
Journal Article
Open access
PDF file
DMDaniel Moore-Palhares
Daniel Moore-Palhares
ADArchya Dasgupta
Archya Dasgupta
MSMurtuza Saifuddin
Murtuza Saifuddin
MAMaria Lourdes Anzola
Maria Lourdes Anzola
SPShopnil Prasla
Shopnil Prasla
GCGregory J Czarnota
Gregory J Czarnota
Background: Preclinical studies have demonstrated that tumour cell death can be enhanced 10- to 40-fold when radiotherapy is combined with focussed ultrasound-stimulated microbubble (FUS-MB) treatment. The acoustic exposure of microbubbles (intravascular gas microspheres) within the target volume causes bubble cavitation, which induces perturbation of tumour vasculature and activates endothelial cell apoptotic pathways responsible for the ablative effect of stereotactic body radiotherapy. Subsequent irradiation of a microbubble-sensitised tumour causes rapid increased tumour death. The study here presents the mature safety and efficacy outcomes of magnetic resonance (MR)-guided FUS-MB (MRgFUS-MB) treatment, a radioenhancement therapy for breast cancer. Methods and findings: This prospective, single-center, single-arm Phase 1 clinical trial included patients with stages I–IV breast cancer with in situ tumours for whom breast or chest wall radiotherapy was deemed adequate by a multidisciplinary team (clinicaltrials.gov identifier: NCT04431674). Patients were excluded if they had contraindications for contrast-enhanced MR or microbubble administration. Patients underwent 2 to 3 MRgFUS-MB treatments throughout radiotherapy. An MR-coupled focussed ultrasound device operating at 800 kHz and 570 kPa peak negative pressure was used to sonicate intravenously administrated microbubbles within the MR-guided target volume. The primary outcome was acute toxicity per Common Terminology Criteria for Adverse Events (CTCAE) v5.0. Secondary outcomes were tumour response at 3 months and local control (LC). A total of 21 female patients presenting with 23 primary breast tumours were enrolled and allocated to intervention between August/2020 and November/2022. Three patients subsequently withdrew consent and, therefore, 18 patients with 20 tumours were included in the safety and LC analyses. Two patients died due to progressive metastatic disease before 3 months following treatment completion and were excluded from the tumour response analysis. The prescribed radiation doses were 20 Gy/5 fractions (40%, n = 8/20), 30 to 35 Gy/5 fractions (35%, n = 7/20), 30 to 40 Gy/10 fractions (15%, n = 3/20), and 66 Gy/33 fractions (10%, n = 2/20). The median follow-up was 9 months (range, 0.3 to 29). Radiation dermatitis was the most common acute toxicity (Grade 1 in 16/20, Grade 2 in 1/20, and Grade 3 in 2/20). One patient developed grade 1 allergic reaction possibly related to microbubbles administration. At 3 months, 18 tumours were evaluated for response: 9 exhibited complete response (50%, n = 9/18), 6 partial response (33%, n = 6/18), 2 stable disease (11%, n = 2/18), and 1 progressive disease (6%, n = 1/18). Further follow-up of responses indicated that the 6-, 12-, and 24-month LC rates were 94% (95% confidence interval [CI] [84%, 100%]), 88% (95% CI [75%, 100%]), and 76% (95% CI [54%, 100%]), respectively. The study’s limitations include variable tumour sizes and dose fractionation regimens and the anticipated small sample size typical for a Phase 1 clinical trial. Conclusions: MRgFUS-MB is an innovative radioenhancement therapy associated with a safe profile, potentially promising responses, and durable LC. These results warrant validation in Phase 2 clinical trials. Trial registration: clinicaltrials.gov, identifier NCT04431674.

6 May 2025 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
DADavid Alberico
David Alberico
LSLakshmanan Sannachi
Lakshmanan Sannachi
MAMaria Lourdes Anzola
Maria Lourdes Anzola
JYJoyce Yip
Joyce Yip
LOLaurentius Oscar Osapoetra
Laurentius Oscar Osapoetra
GCGregory J Czarnota
Gregory J Czarnota
Previous work has demonstrated quantitative ultrasound (QUS) analysis techniques for extracting features and texture features from ultrasound radiofrequency data which can be used to distinguish between benign and malignant breast masses. It is desirable that there be good agreement between estimates of such features acquired using different ultrasound devices. Handheld ultrasound imaging systems are of particular interest as they are compact, relatively inexpensive, and highly portable. This study investigated the agreement between QUS parameters and texture features estimated from clinical ultrasound images of breast tumors acquired using two different ultrasound scanners: a traditional cart-based system and a wireless handheld ultrasound system. The 28 patients who participated were divided into two groups (benign and malignant). The reference phantom technique was used to produce functional estimates of the normalized power spectra and backscatter coefficient for each image. Root mean square differences of feature estimates were calculated for each cohort to quantify the level of feature variation attributable to tissue heterogeneity and differences in system imaging parameters. Cross-system statistical testing using the Mann–Whitney U test was performed on benign and malignant patient cohorts to assess the level of feature estimate agreement between systems, and the Bland–Altman method was employed to assess feature sets for systematic bias introduced by differences in imaging method. The range of p-values was 1.03 × 10−4 to 0.827 for the benign cohort and 3.03 × 10−10 to 0.958 for the malignant cohort. For both cohorts, all five of the primary QUS features (MBF, SS, SI, ASD, AAC) were found to be in agreement at the 5% confidence level. A total of 13 of the 20 QUS texture features (65%) were determined to exhibit statistically significant differences in the sample medians of estimates between systems at the 5% confidence level, with the remaining 7 texture features being in agreement. The results showed a comparable magnitude of feature variation between tissue heterogeneity and system effects, as well as a moderate level of statistical agreement between feature sets.

30 September 2025 in Tomography
Verified
Journal Article
Open access
PDF file
MAMaria Lourdes Anzola
Maria Lourdes Anzola
DADavid Alberico
David Alberico
JYJoyce Yip
Joyce Yip
JWJAMES WISKIN
JAMES WISKIN
BMBilal Malik
Bilal Malik
GCGregory J Czarnota
Gregory J Czarnota
Breast cancer detection remains a significant challenge, with traditional mammography presenting barriers such as discomfort, radiation exposure, high false-positive rates, and financial burden. Moreover, younger women frequently fall outside routine mammographic screening guidelines, leaving critical gaps in early detection. Objectives: This study investigates the potential of quantitative transmission breast acoustic computed tomography scanner imaging (QT3D) as an innovative, non-invasive imaging modality for characterizing and evaluating breast masses. Methods: A comparative analysis between QT3D imaging and magnetic resonance imaging (MRI) was conducted in a cohort of patients with biopsy-proven benign or malignant breast lesions, comparing key metrics in quantifying breast masses for the purposes of breast mass characterization. Results: The findings in this study highlight its capability in identifying relatively small tumors, multiple lesions, satellite lesions, intraductal extensions, and calcifications, in addition to offering valuable diagnostic insights. Conclusions: This work is a first step toward studies essential for confirming its clinical feasibility, establishing its role in breast cancer tumor characterization, and potentially improving patient outcomes.

28 November 2025 in Cancers
Verified
Journal Article
Open access
PDF file
LOLaurentius Oscar Osapoetra
Laurentius Oscar Osapoetra
GDGraham Dinniwell
Graham Dinniwell
MAMaria Lourdes Anzola
Maria Lourdes Anzola
DADavid Alberico
David Alberico
LSLakshmanan Sannachi
Lakshmanan Sannachi
GCGregory J Czarnota
Gregory J Czarnota
Background/Objectives: To evaluate the ability of radiomics analysis of QUS spectral parametric imaging to non-invasively differentiate intermediate-to-high-risk from low-risk Oncotype DXTM Recurrence Score (ODXRS). Methods: This prospective study included 31 participants (21 intermediate-to-high-risk ODXRS (median age, 56 years [IQR: 49–68 years]) and 10 low-risk ODXRS (median age, 52 years [IQR: 48–58 years])) presenting with ER+ HER2− invasive breast masses acquired between September 2015 and August 2024. Quantitative ultrasound (QUS) spectroscopy produced five spectral maps, from which radiomics features (including statistical, texture, and morphological measures) were extracted from the tumor core and a 5 mm margin. The ground truth label was determined from thresholding the ODXRS. A multivariate predictive model was developed to differentiate intermediate-to-high-risk ODXRS from low-risk ODXRS, with performance assessed via nested leave-one-out cross-validation (LOOCV). Results: A nested leave-one-out cross-validation (LOOCV) analysis demonstrated the generalization performance of a four-feature model. The support vector machine (SVM-RBF) classifier achieved 86% recall, 100% specificity, 93% balanced accuracy, and an area under the receiver operating characteristic curve (AUROC) of 0.95 (CI = 0.88–1.00) in identifying intermediate-to-high-risk versus low-risk ODXRS. Conclusions: The preliminary results suggest the potential radiomics-based model of ODXRS in predicting the risks of recurrence. The results warrant further investigation on a larger cohort. This framework can be a useful surrogate for participants for whom ODX testing is neither affordable nor available.

13 March 2026 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
DADavid Alberico
David Alberico
MAMaria Lourdes Anzola
Maria Lourdes Anzola
LOLaurentius Oscar Osapoetra
Laurentius Oscar Osapoetra
LSLakshmanan Sannachi
Lakshmanan Sannachi
JYJoyce Yip
Joyce Yip
GCGregory J Czarnota
Gregory J Czarnota
This study assessed the level of agreement between quantitative ultrasound (QUS) feature estimates derived from ultrasound images of breast tumors in women with locally advanced breast cancer (LABC) produced using a cart-based and a handheld ultrasound system. Thirty LABC patients receiving neoadjuvant chemotherapy were imaged at two separate times: a pre-treatment ‘baseline’ time point, and four weeks after the start of chemotherapy. Three sets of QUS features were produced using the reference phantom technique, one for each imaging time and a third set calculated by taking the differences in feature estimates between times. Cross-system statistical testing using the Wilcoxon signed-rank test was performed for each feature set to assess the level of feature estimate agreement between ultrasound systems. The Bland–Altman method was employed to graphically assess feature sets for systematic skew. The range of p-values was 4.50 × 10−11 to 0.277 for the baseline features, 2.77 × 10−5 to 0.865 for the week 4 features, and 2.03 × 10−9 to 1 for the feature differences. For the feature differences, all five of the primary QUS features (MBF, SS, SI, ASD, AAC) were found to be in agreement between the two scanner types at the 5% confidence level. For the baseline feature set and week 4 feature set, 0 out of 5 and 3 out of 5 of the primary features were found to be in agreement, respectively. Of the 20 QUS texture features examined, the number and proportion of the total for each feature set which were found to have statistically significant similarity in their sample medians at the 5% confidence level were as follows: 2 out of 20 (10%) for the baseline features; 17 out of 20 (85%) for the week 4 features; and 12 out of 20 (60%) for the feature differences. The specific texture features found to be in agreement varied between QUS-specific feature sets. Overall, a moderate level of agreement between sets of feature differences produced using the two systems was demonstrated.