Sharafatdin Yessirkepov

Mr. Sharafatdin Yessirkepov

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 December 2023 in Robotics
Verified
Journal Article
Open access
PDF file
Michele FolgheraiterMichele Folgheraiter
Michele Folgheraiter
SYSharafatdin Yessirkepov
Sharafatdin Yessirkepov
TUTimur Umurzakov
Timur Umurzakov
This paper presents the design of a new lightweight, full-size bipedal robot developed in the Humanoid Robotics Laboratory at Nazarbayev University. The robot, equipped with 12 degrees of freedom (DOFs), stands at 1.1 m tall and weighs only 15 kg (excluding the battery). Through the implementation of a simple mechanical design and the utilization of off-the-shelf components, the overall prototype cost remained under USD 5000. The incorporation of high-performance in-house-developed servomotors enables the robot’s actuation system to generate up to 2400 W of mechanical power, resulting in a power-to-weight ratio of 160 W/kg. The details of the mechanical and electrical design are presented alongside the formalization of the forward kinematic model using the successive screw displacement method and the solution of the inverse kinematics. Tests conducted in both a simulation environment and on the real prototype demonstrate that the robot is capable of accurately following the reference joint trajectories to execute a quasi-static gait, achieving an average power consumption of 496 W.

4 December 2024 in Robotics
Verified
Journal Article
Open access
PDF file
SYSharafatdin Yessirkepov
Sharafatdin Yessirkepov
Michele FolgheraiterMichele Folgheraiter
Michele Folgheraiter
AAArman Abakov
Arman Abakov
TUTimur Umurzakov
Timur Umurzakov
One of the most challenging aspects of designing a humanoid robot is ensuring stable walking. To achieve this, the kinematic architecture must support 3D motion and maintain equilibrium, particularly during single-foot support. Without proper configuration, the robot may experience unbalanced weight distribution, significantly increasing the risk of falling while walking. While adding redundant degrees of freedom (DOFs) can enhance adaptability, it also raises the system’s complexity and cost and the need for more sophisticated control strategies and higher energy consumption. This paper explores a reduced-DOF bipedal robot, which, despite its limited number of DOFs, is capable of performing 3D motion. It features an inverted pendulum and elastic ankles made of thermoplastic polyurethane (TPU), enabling effective balance control and attenuation of disturbances. The robot’s electromechanical design is introduced alongside the kinematic model. Momentum equilibrium in a pseudo-static mode is considered in both the frontal and sagittal planes, taking into account the pendulum and the swinging leg during the single support phase. The TPU ankle’s performance is assessed based on its ability to resist external bending forces, highlighting challenges related to the robot’s weight equilibrium stability and ankle inversion. Experimental results from both Finite Element Analysis (FEA) and real-world tests are compared. Lastly, the joint movements of the inverted pendulum-based biped robot are evaluated in both a virtual environment and a physical prototype while performing lateral tilting and various gait sequences.

16 June 2025 in IEEE Access
Verified
Journal Article
Open access
TUTimur Umurzakov
Timur Umurzakov
SYSharafatdin Yessirkepov
Sharafatdin Yessirkepov
Michele FolgheraiterMichele Folgheraiter
Michele Folgheraiter
This paper proposes a neural network-based model of a novel hybrid Series-Parallel Elastic Actuator (SEA-PEA) architecture for high-performance robotic applications. The system combines a Brushless DC (BLDC) motor, a planetary gearbox, and a rotary pneumatic actuator serving as an elastic element. While the gearbox offers advantages such as low cost and back-drivability, it suffers from significant backlash due to manufacturing tolerances. To address this, the actuator connects the gearbox output shaft directly to that of the pneumatic actuator. For a parallel configuration, both stators are mounted on an aluminum holder supporting the entire assembly. Within the backlash region, the system behaves as a Series Elastic Actuator (SEA), with the pneumatic actuator’s elasticity influencing stiffness, damping, and inertia. Outside this region, the system transitions to a Parallel Elastic Actuator (PEA), rigidly coupling the motor and gearbox shafts. A hybrid modeling approach is introduced to capture the actuator’s dynamic response. The SEA behavior is modeled using a black-box Artificial Neural Network (ANN), specifically an Echo State Network (ESN), which showed the lowest mean squared error (MSE) among the tested architectures. The PEA behavior is modeled using a gray-box approach, combining a linear dynamic block with a nonlinear static block represented by an ANN (Wiener model). This hybrid framework, integrating an ESN, achieved lower prediction error and better performance than other ANN architectures, as confirmed by experimental results.

9 January 2025 in IEEE Access
Verified
Journal Article
Open access
SYSharafatdin Yessirkepov
Sharafatdin Yessirkepov
TUTimur Umurzakov
Timur Umurzakov
Michele FolgheraiterMichele Folgheraiter
Michele Folgheraiter
This paper presents an innovative hybrid cable-driven shoulder joint for humanoid robotics application. A blend of a flexible central limb and three rigid lateral limbs, form a 2-degree-of-freedom (2 DOF) mechanism that connects the mobile platform to the fixed base. This design leverages both good mechanical stability and the integration of an elastic element, which mitigate vibrations up to 40% and allow the storage and release of elastic potential energy up to 1.9 J. Initially, three alternative and incremental shoulder joint designs are presented and evaluated across two distinct experiments: 1) Energy storage analysis of the parallel mechanism during single cable motion and 2) Dynamic response and vibration damping. Following these experiments, a detailed analysis is performed on the stiffness properties of the proposed prototype, as it outperforms the other two designs. The dimension of the central elastic limb, made out of Thermo-Plastic Polyurethane (TPU), is optimized using Finite Element Analysis (FEA). The kinematic behavior of the proposed mechanism is approximated as a combination of linkages equipped with two universal joints, and its motion evaluated through numerical simulations and real experiments.

15 July 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
SYSharafatdin Yessirkepov
Sharafatdin Yessirkepov
ATAdilet Toleshev
Adilet Toleshev
ANAibek Niyetkaliyev
Aibek Niyetkaliyev
AKAli Kaiyrdykozha
Ali Kaiyrdykozha
AOAiman Ozhikenova
Aiman Ozhikenova
IYIgembay Yerbolat
Igembay Yerbolat
This article outlines a customizable geometric optimization, force modeling, and experimental evaluation of a compact, 3D-printed antagonistic cable-driven robotic elbow joint intended for upper-limb medical rehabilitation. Cable-driven parallel manipulators (CDPRs) offer significant advantages for wearables by minimizing distal mass and inertia, though they require meticulous tension and workspace management to ensure cables remain taut without structural or cable-link collisions. The proposed single-degree-of-freedom joint uses a biologically inspired dual-cable architecture alongside a unique Bowden cable sheath routing mechanism to mitigate cable interference and expand the operational workspace. Analytical models for inverse kinematics and static equilibrium were formulated to define optimal geometric parameters, establishing that a base-to-platform distance of h = 240 mm with a platform diameter D = 80 mm balances a 135° flexion range of motion with efficient actuator demands. Implementing a hardware-in-the-loop control loop via MATLAB/Simulink, the architecture combines position and force-bounded strategy. Experimental validations on the physical prototype demonstrate excellent agreement between theoretical predictions and empirical measurements for both cable displacements and tension control.

28 February 2026 in Traumatology and Orthopаedics of Kazakhstan
Verified
Journal Article
Open access
PDF file
SYSharafatdin Yessirkepov
Sharafatdin Yessirkepov
MKMadina Karasheva
Madina Karasheva
BABauyrzhan Askarov
Bauyrzhan Askarov
AOAssylbek Ozhiken
Assylbek Ozhiken
CAChingiz Alimbayev
Chingiz Alimbayev
АЖАлимбаева Ж.
Алимбаева Ж.
Every year, stroke-induced upper limb impairment impacts millions of people worldwide, necessitating intensive rehabilitation to regain motor control. While conventional physical therapy and end-effector-based robots have been utilized, they often face limitations such as high labor costs, therapist fatigue, and an inability to control the redundancy of the human arm, which can lead to nonphysiologic compensatory movements. To address these challenges, this paper presents the development of the hybrid shoulder rehabilitation exoskeleton, an advanced iteration of the previous HYBRID-1 prototype. The hybrid shoulder exoskeleton introduces two major design modifications based on performance evaluations and cable tension issues identified in the initial version. First, the shoulder girdle mechanism was redesigned by replacing the inverted slider-crank linkage with a planar crank-rocker four-bar linkage consisting of four revolute joints to better align with human anatomy. Second, a novel pretension mechanism was integrated into the Cable-Driven Parallel Mechanism to prevent cable derailment and maintain consistent tension using a system of rods, rollers, and compression springs. The design was first validated through a 3D-printed miniature model and CAD simulations, which confirmed the accuracy of the forward and inverse kinematic models. Subsequently, a real-scale prototype was manufactured featuring an adjustable shoulder cuff and additional base support to enhance structural stability for clinical applications. Initial assembly and preliminary testing indicate that these modifications provide a robust platform for intensive, task-specific rehabilitation. Future work will focus on performance testing with healthy subjects to evaluate the system’s adaptability to various body parameters such as height and arm diameter.