Akanksha Vishwadeep Waghmare

Ms. Akanksha Vishwadeep Waghmare


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 August 2025 in Discover Applied Sciences
Verified
Journal Article
Open access
PDF file
AWAkanksha Vishwadeep Waghmare
Akanksha Vishwadeep Waghmare
VSVinay Pratap Singh
Vinay Pratap Singh
TVTarun Varshney
Tarun Varshney
Sanjeevikumar PadmanabanSanjeevikumar Padmanaban
Sanjeevikumar Padmanaban
Microgrids are being considered to be very crucial in enhancing the involvement of renewable energy sources (RESs) in electrical grids and also improving their overall sustainability and resilience. Modern day control techniques are getting attention by researchers for optimal control and management of microgrids, as it is found in many articles that classical control techniques are short-falling in adaptability in different environments, data handling and data driven decision making. This article provides systematic review to follow a thorough evaluation of the present status of research on reinforcement learning (RL)-based microgrid control. The description of microgrid systems, their components, control and management challenges are also provided in this survey. Further, majorly implemented RL-based algorithms for microgrid control are discussed. Summary and critical assessment of main findings and contributions in this field are tabulated through methodical categorization of selected articles. Emerging algorithms for microgrid control are also discussed thoroughly. A comparative analysis based on performance of RL algorithms, and RL based control with other types of control frameworks is also systematically presented. Further safety and deploying challenges, along with ongoing trends in RL implementation for microgrids, are elaborated. This work will be helpful for practitioners and researchers who want to investigate the best way to design microgrid systems, especially when it comes to using RL algorithms for microgrid control systems and management.

4 March 2024 in IEEE Access
Verified
Journal Article
Open access
MAMamta
Mamta
VSVinay Pratap Singh
Vinay Pratap Singh
AWAkanksha Vishwadeep Waghmare
Akanksha Vishwadeep Waghmare
VMV. P. Meena
V. P. Meena
Francesco BenedettoFrancesco Benedetto
Francesco Benedetto
TVTarun Varshney
Tarun Varshney
Automatic generation control (AGC) is employed in power systems to maintain balance between generation and load by adjusting output of generators in real time. Controller continuously monitors system frequency and tie-line power flow by responding to fluctuations in electricity demand and supply and optimizes generator dispatch, reduces power imbalances, and enhances grid stability. This work proposes and solves the issues of the AGC in two-area interconnected power systems by proposing a new approach based on both Jaya algorithm and the rank exponent method. In particular, we design a proportional-integral-derivative controller with derivative filtering (PIDm), where the effect of the noise is mitigated by the use of a filter with derivative gain. We propose to build the objective function, to tune the controller’s parameters, as the linear combination of three sub-objectives, namely integral of time multiplied absolute error (ITAE) for frequency deviations, tie-line power deviation, and area-control errors (ACEs). The rank method is exploited to evaluate the weights of these sub-objectives, while the final overall objective function is minimized exploiting the Jaya algorithm. The proposed controller’s performance is assessed in six different scenarios with load disturbances, and its effectiveness is compared to state-of-art controllers tuned using salp swarm algorithm (SSA), Nelder-Mead simplex (NMS), symbiotic organisms search (SOS), elephant herding optimization (EHO), and Luus-Jaakola (LJ) optimization algorithms. To illustrate the frequency and tie-line power changes, results are also shown, and a statistical study is finally carried out to evaluate the recommended controller’s overall effectiveness. Additionally, Friedman rank test as no-parametric statistical analysis is also done in order to evaluate the significance level of optimization algorithms. Our numerical findings evidence that the proposed PIDm controller outperforms other existing optimization-based controllers in terms of performance and utility, thus proving to be very effective for handling AGC issues in two-are interconnected power systems.

16 January 2024 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
VSVinay Pratap Singh
Vinay Pratap Singh
UMESH KUMAR YADAVUMESH KUMAR YADAV
UMESH KUMAR YADAV
VMV. P. Meena
V. P. Meena
AWAkanksha Vishwadeep Waghmare
Akanksha Vishwadeep Waghmare
AGAnkur Gupta
Ankur Gupta
BPBhanu Pratap
Bhanu Pratap
The presented research proposal focuses on the approximation of higher-order (HO) multi-input multi-output (MIMO) interconnected power system model (IPSM) by employing systematic approach of proximity index value (PIV) based weight ascertainment method. The approximation of HO MIMO IPSM is accomplished by utilizing expansion parameters of HO MIMO IPSM and its desired lower-order model (LOM). The expansion parameters of HO MIMO IPSM and its LOM are exploited to construct the fitness-function. In the fitness-function weights are assigned to achieve better LOM by improving the steady-state and transient responses with respect to HO MIMO IPSM. The weights of constructed fitness-function are determined with the help of PIV method. Then obtained weighted fitness-function is optimized by satisfying the two prime constraints i.e. matching of steady-state response and preservation of stability of IPSM. To demonstrate the efficacy of the proposed systematic approximation methodology, nineteenth order IPSM is approximated to LOM of second order IPSM. Additionally, specifications of time-domain and error-indices along with responses of the proposed LOM are compared with other LOMs obtained using different approximation approaches, with respect to HO IPSM to depict the effectiveness and applicability of the proposed approach.

19 May 2025 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
RCRicha Chaudhary
Richa Chaudhary
VSVinay Pratap Singh
Vinay Pratap Singh
AMAkhilesh Mathur
Akhilesh Mathur
UMESH KUMAR YADAVUMESH KUMAR YADAV
UMESH KUMAR YADAV
AWAkanksha Vishwadeep Waghmare
Akanksha Vishwadeep Waghmare
Josep M. GuerreroJosep M. Guerrero
Josep M. Guerrero
This paper introduces an efficient method for reduced-order modeling of a fuel cell-integrated autonomous microgrid (AMG) utilizing the simple multi-attribute rating technique (SMART). The higher-order system (HOS) of the AMG is reduced to a second-order model, ensuring computational efficiency while retaining the system's essential characteristics. Time moments (TMs) and Markov parameters (MPs), well-known for their ability to simplify complex systems, play a central role in this process. Their use not only decreases computational demands but also enhances understanding of the HOS dynamics, making them valuable for deriving low-order approximations.The proposed method constructs three sub-objective functions based on TMs and MPs, with weights determined through the SMART technique to refine both transient and steady-state responses. These sub-objective functions are then combined into a single objective function, which is minimized using the brown bear optimization algorithm (BBOA). Stability and steady-state performance are maintained by imposing constraints, including adherence to the Hurwitz criterion and ensuring zero steady-state error. To validate the approach, the reduced model is evaluated through Bode, step, impulse, and Nyquist response comparisons with the original system. The proposed reduced order model (ROM) is also benchmarked against existing techniques, highlighting its improved accuracy and efficiency. Additionally, error indices and time-domain parameters are provided to support the findings. This study underscores the importance of TMs and MPs in achieving computationally efficient and insightful ROMs for autonomous microgrids, offering a reliable framework for system analysis and optimization.

1 July 2026 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
AWAkanksha Vishwadeep Waghmare
Akanksha Vishwadeep Waghmare
VSVinay Pratap Singh
Vinay Pratap Singh
Josep M. GuerreroJosep M. Guerrero
Josep M. Guerrero
SSS. P. Singh
S. P. Singh
AMAkhilesh Mathur
Akhilesh Mathur

20 November 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
VSVinay Pratap Singh
Vinay Pratap Singh
AWAkanksha Vishwadeep Waghmare
Akanksha Vishwadeep Waghmare
VMV. P. Meena
V. P. Meena
UYU. K. Yadav
U. K. Yadav
TVTarun Varshney
Tarun Varshney
Automatic generation control (AGC) plays a vital role in creating an equilibrium between generated output power and load demand, in order to maintain frequency at desired value. This study focuses on performance analysis of simple-multi attribute rating technique (SMART) assisted proportional-integral-derivative (PID) controller design for AGC of two interconnected power systems. PID controller is designed by minimizing frequency variations, area control errors for area-1 and area-2, and tie-line power deviation. An objective function is framed considering error minimization of aforementioned factors as sub-objectives. The construction of objective function involves using the integral of time-multiplied absolute error (ITAE) for frequency deviations for area-1 and area-2, ITAE for deviation in tie-line power, and ITAEs for area control errors for area-1 and area-2 as sub-objective functions. By assigning appropriate weights to these sub-objective functions, an overall objective function is formed. This study determines these weights in an organized manner using SMART method, rather than randomly/equally assigning them. Overall objective function is minimized using Jaya algorithm. To demonstrate effectiveness of the proposed Jaya-based PID controller, its performance is analysed and compared with controllers tuned using other optimization algorithms, including sine cosine, Luus-Jaakola, teacher-learner based optimization, Nelder-Mead simplex, and elephant herding optimization. Considering six different case studies that consider a range of load variations, responses for fluctuations in frequency and tie-line exchange are plotted. Statistical and non-parametric analysis performed further provide additional insights into the performance of Jaya-based PID controller.