Flexible sensors used to detect NO2 gas generally have problems such as poor repeatability, high operating temperature, poor selectivity, and small detection range. In this work, a new spraying platform with a simple structure, low cost, and good film-forming consistency was designed and built to make a sensitive film (rGO/SnO2) for NO2 gas sensors. The relationship between the solid content of rGO and SnO2 nanoparticles, annealing temperature, and sensor performance was studied. The results show that the interdigital electrode-sensitive film formed by spraying 0.25 ml of a 0.4 wt% rGO/SnO2 mixture and annealing at 250 °C exhibited the best comprehensive performance for NO2 detection. The sensor’s response value for 100 ppm NO2 gas was 0.2640 at room temperature (25 °C), and the response time and recovery time were 412.4 s and 587.3 s, respectively. In the range of 20–100 ppm, the relationship between the response and NO2 concentration was linear, and the correlation coefficient was 0.9851. In addition, a soft-monitoring node module with an overlimit warning function for NO2 gas was designed and manufactured based on flexible electronics. Finally, the flexible sensor and node module were embedded into woven fabric that could be used to make a mask or a watch that could detect NO2 gas, realizing the practical application of flexible NO2 gas sensors in the field of wearable electronics.
17 March 2021 in IEEE Transactions on Instrumentation and Measurement
A new fiber Bragg grating (FBG) sensor that can measure temperature, vibration, and strain is proposed in this article. The structure of this sensor is designed and optimized via theoretical analysis and the finite-element method (FEM). With an innovatively designed L-shaped cantilever (LSC), this designed sensor can better balance the vibration measurement sensitivity and the resonant frequency. The strain measurement structure is designed as a hollow square so that the reaction force of the sensor for the measured object is only 2.76×10 -3 N/ με, which ensures that the strain distribution of the measured object is not affected. The designed sensor can significantly amplify the measured strain with a measurement sensitivity (5.44 pm/ με) that is four times greater than that of the bare FBGs. This article uses single-mode FBGs inscribed by a femtosecond laser (FS-FBG) to make the sensors, and the sensing performance is analyzed. The results show that this FS-FBG-based sensor can withstand temperatures up to 1100 °C.
22 October 2021 in IEEE Transactions on Instrumentation and Measurement
A compact vector magnetometer based on balloon-like fiber structure functionalized by magnetic fluid (MF) was proposed. To fabricate the sensor, the single mode fiber (SMF) was bent into a balloon-like structure, and then the shape was fixed by using the alcohol lamp flame. Because of the bending, the fiber core mode leaks into the cladding, thereby forming higher order cladding modes that are sensitive to the variations of external refractive index. When the structure is encapsulated in MF, due to the anisotropic distribution of ferromagnetic nanoparticles under magnetic field, the refractive index around the fiber structure also presents anisotropy. By measuring the refractive index of the MF under different magnetic-field directions and intensities, both the measurement of the magnetic field intensity and direction can be achieved. The experimental results show that a high magnetic field intensity sensitivity of 0.78 nm/mT and a high magnetic-field direction sensitivity of 0.094°/mT were obtained. Due to the simple fabricating method, low cost, and highly sensitivity, the proposed fiber vector magnetometer has potential applications in the navigation, aviation, and electric power industry.
30 April 2021 in Measurement Science and Technology
In this paper, a novel optical fiber surface plasmon resonance (SPR) magnetic field sensor is proposed and experimentally demonstrated. The structure is fabricated by splicing a section of photonic crystal fiber between two multimode fibers. After the structure is coated with 10 nm Cr and 50 nm Au, the high refractive index (RI) sensitivity, from 1973.72 nm RIU −1 to 3223.32 nm RIU −1 in the range of 1.3326–1.3680, verifies the SPR sensor, which is higher than the structure based on single mode fiber with the same coating. In addition, the microscopic mechanism of the tunable characteristics of magnetic fluid RI with the ambient magnetic field is simulated by the molecular dynamics method. To measure the external magnetic field, the sensing region of the SPR sensor is fully inserted in a capillary tube, which is filled with magnetic fluid and sealed with UV glue. A maximum sensitivity of 4.42 nm mT −1 is achieved in the range of 0–24 mT, experimentally. Due to high sensitivity, simple manufacturing and compact size, the proposed sensor possesses attractive application prospects in environmental monitoring, power transmission and biomedical applications.
In the present study, a high-performance n-type temperature sensor was developed by a new and facile synthesis approach, which could apply to ambient temperature applications. As impacted by the low sintering temperature of flexible polyimide substrates, a screen printing technology-based method to prepare thermoelectric materials and a low-temperature heat treatment process applying to polymer substrates were proposed and achieved. By regulating the preparation parameters of the high-performance n-type indium oxide material, the optimal proportioning method and the post-treatment process method were developed. The sensors based on thermoelectric effects exhibited a sensitivity of 162.5 μV/°C, as well as a wide range of temperature measurement from ambient temperature to 223.6 °C. Furthermore, it is expected to conduct temperature monitoring in different scenarios through a sensor prepared in masks and mechanical hands, laying a foundation for the large-scale manufacturing and widespread application of flexible electronic skin and devices.
Magnetometers based on nitrogen-vacancy (NV) centers in diamonds have promising applications in fields of living systems biology, condensed matter physics, and industry. This paper proposes a portable and flexible all-fiber NV center vector magnetometer by using fibers to substitute all conventional spatial optical elements, realizing laser excitation and fluorescence collection of micro-diamond with multi-mode fibers simultaneously and efficiently. An optical model is established to investigate multi-mode fiber interrogation of micro-diamond to estimate the optical performance of NV center system. A new analysis method is proposed to extract the magnitude and direction of the magnetic field, combining the morphology of the micro-diamond, thus realizing μm-scale vector magnetic field detection at the tip of the fiber probe. Experimental testing shows our fabricated magnetometer has a sensitivity of 0.73 nT/Hz1/2, demonstrating its feasibility and performance in comparison with conventional confocal NV center magnetometers. This research presents a robust and compact magnetic endoscopy and remote-magnetic measurement approach, which will substantially promote the practical application of magnetometers based on NV centers.