Angel Torrado-Carvajal

Prof. Dr. Angel Torrado-Carvajal


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 August 2018 in Journal of Nuclear Medicine
Verified
Journal Article
Open access
PDF file
ATAngel Torrado-Carvajal
Angel Torrado-Carvajal
JVJavier Vera-Olmos
Javier Vera-Olmos
DGDavid Izquierdo Garcia
David Izquierdo Garcia
OCOnofrio A. Catalano
Onofrio A. Catalano
MMManuel A. Morales
Manuel A. Morales
CCCiprian Catana
Ciprian Catana
Whole-body attenuation correction (AC) is still challenging in combined PET/MR scanners. We describe Dixon-VIBE Deep Learning (DIVIDE), a deep-learning network that allows synthesizing pelvis pseudo-CT maps based only on the standard Dixon volumetric interpolated breath-hold examination (Dixon-VIBE) images currently acquired for AC in some commercial scanners. Methods: We propose a network that maps between the four 2-dimensional (2D) Dixon MR images (water, fat, in-phase, and out-of-phase) and their corresponding 2D CT image. In contrast to previous methods, we used transposed convolutions to learn the up-sampling parameters, we used whole 2D slices to provide context information, and we pretrained the network with brain images. Twenty-eight datasets obtained from 19 patients who underwent PET/CT and PET/MR examinations were used to evaluate the proposed method. We assessed the accuracy of the μ-maps and reconstructed PET images by performing voxel- and region-based analysis comparing the SUVs (in g/mL) obtained after AC using the Dixon-VIBE (PETDixon), DIVIDE (PETDIVIDE), and CT-based (PETCT) methods. Additionally, the bias in quantification was estimated in synthetic lesions defined in the prostate, rectum, pelvis, and spine. Results: Absolute mean relative change values relative to CT AC were lower than 2% on average for the DIVIDE method in every region of interest except for bone tissue, where it was lower than 4% and 6.75 times smaller than the relative change of the Dixon method. There was an excellent voxel-by-voxel correlation between PETCT and PETDIVIDE (R2 = 0.9998, P < 0.01). The Bland–Altman plot between PETCT and PETDIVIDE showed that the average of the differences and the variability were lower (mean PETCT–PETDIVIDE SUV, 0.0003; PETCT–PETDIVIDE SD, 0.0094; 95% confidence interval, [−0.0180,0.0188]) than the average of differences between PETCT and PETDixon (mean PETCT–PETDixon SUV, 0.0006; PETCT–PETDixon SD, 0.0264; 95% confidence interval, [−0.0510,0.0524]). Statistically significant changes in PET data quantification were observed between the 2 methods in the synthetic lesions, with the largest improvement in femur and spine lesions. Conclusion: The DIVIDE method can accurately synthesize a pelvis pseudo-CT scan from standard Dixon-VIBE images, allowing for accurate AC in combined PET/MR scanners. Additionally, our implementation allows rapid pseudo-CT synthesis, making it suitable for routine applications and even allowing retrospective processing of Dixon-VIBE data.

21 November 2019 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
ASAlireza Sadeghi-Tarakameh
Alireza Sadeghi-Tarakameh
LDLance DelaBarre
Lance DelaBarre
RLRussell L. Lagore
Russell L. Lagore
ATAngel Torrado-Carvajal
Angel Torrado-Carvajal
XWXiaoping Wu
Xiaoping Wu
YEYigitcan Eryaman
Yigitcan Eryaman

16 September 2021 in Brain
Verified
Journal Article
Open access
PDF file
ZAZeynab Alshelh
Zeynab Alshelh
LBLudovica Brusaferri
Ludovica Brusaferri
ASAtreyi Saha
Atreyi Saha
EMErin Morrissey
Erin Morrissey
PKPaulina Knight
Paulina Knight
MLMarco L Loggia
Marco L Loggia
We recently showed that patients with different chronic pain conditions (such as chronic low back pain, fibromyalgia, migraine and Gulf War illness) demonstrated elevated brain and/or spinal cord levels of the glial marker 18-kDa translocator protein (TSPO), which suggests that neuroinflammation might be a pervasive phenomenon observable across multiple aetiologically heterogeneous pain disorders. Interestingly, the spatial distribution of this neuroinflammatory signal appears to exhibit a degree of disease specificity (e.g. with respect to the involvement of the primary somatosensory cortex), suggesting that different pain conditions may exhibit distinct ‘neuroinflammatory signatures’. To explore this hypothesis further, we tested whether neuroinflammatory signal can characterize putative aetiological subtypes of chronic low back pain patients based on clinical presentation. Specifically, we explored neuroinflammation in patients whose chronic low back pain either did or did not radiate to the leg (i.e. ‘radicular’ versus ‘axial’ back pain). Fifty-four patients with chronic low back pain, 26 with axial back pain [43.7 ± 16.6 years old (mean ± SD)] and 28 with radicular back pain (48.3 ± 13.2 years old), underwent PET/MRI with 11C-PBR28, a second-generation radioligand for TSPO. 11C-PBR28 signal was quantified using standardized uptake values ratio (validated against volume of distribution ratio; n = 23). Functional MRI data were collected simultaneously to the 11C-PBR28 data (i) to functionally localize the primary somatosensory cortex back and leg subregions; and (ii) to perform functional connectivity analyses (in order to investigate possible neurophysiological correlations of the neuroinflammatory signal). PET and functional MRI measures were compared across groups, cross-correlated with one another and with the severity of ‘fibromyalgianess’ (i.e. the degree of pain centralization, or ‘nociplastic pain’). Furthermore, statistical mediation models were used to explore possible causal relationships between these three variables. For the primary somatosensory cortex representation of back/leg, 11C-PBR28 PET signal and functional connectivity to the thalamus were: (i) higher in radicular compared to axial back pain patients; (ii) positively correlated with each other; (iii) positively correlated with fibromyalgianess scores, across groups; and finally (iv) fibromyalgianess mediated the association between 11C-PBR28 PET signal and primary somatosensory cortex–thalamus connectivity across groups. Our findings support the existence of ‘neuroinflammatory signatures’ that are accompanied by neurophysiological changes and correlate with clinical presentation (in particular, with the degree of nociplastic pain) in chronic pain patients. These signatures may contribute to the subtyping of distinct pain syndromes and also provide information about interindividual variability in neuroimmune brain signals, within diagnostic groups, that could eventually serve as targets for mechanism-based precision medicine approaches.

22 October 2015 in Journal of Nuclear Medicine
Verified
Journal Article
Open access
PDF file
ATAngel Torrado-Carvajal
Angel Torrado-Carvajal
JHJOAQUIN L. HERRAIZ
JOAQUIN L. HERRAIZ
EAEduardo Alcain
Eduardo Alcain
AMAntonio S. Montemayor
Antonio S. Montemayor
LGLina Garcia-Cañamaque
Lina Garcia-Cañamaque
NMNorberto Malpica
Norberto Malpica
Attenuation correction in hybrid PET/MR scanners is still a challenging task. This paper describes a methodology for synthesizing a pseudo-CT volume from a single T1 weighted volume, thus allowing us to create correct AC maps. Methods: We propose a fast pseudo-CT generation from a patient-specific MRI T1-weighted image using a group-wise patch-based approach and a MRI-CT atlas dictionary. For every voxel in the input MR image, we compute the similarity of the patch containing that voxel with the patches of all MR images in the database, that lie in a certain anatomical neighborhood. The pseudo-CT is obtained as a local weighted linear combination of the CT values of the corresponding patches. The algorithm was implemented in a Graphical Processing Unit. Results: We evaluated our method both qualitatively and quantitatively for PET/MR correction. The approach performed successfully in all cases considered. We compared the SUVs of the PET image obtained after attenuation correction using the patient specific CT volume, and using the corresponding computed pseudo-CT volume. The voxel by voxel correlation between SUV obtained with both methods was very high (R2=0.9980, p<0.0001), while the Bland-Altman test showed that the average of the differences was very low (0.0006±0.0594). A region of interest analysis was also performed. The correlation between mean SUV value and maximum SUV value of every region was very high (R2=0.9989, p<0.0001 and R2=0.9904, p<0.0001, respectively). Conclusion: Results indicate how our method can accurately approximate the patient-specific CT and may serve as a potential solution for accurate attenuation correction in hybrid PET/MR systems. The quality of the corrected PET using our pseudo-CT is comparable to having acquired a patient-specific CT, thus, improving the results obtained with the UTE-based attenuation correction maps currently used in the mMR scanner. The GPU implementation led to a substantial decrease in computational time making the approach suitable for real applications.

28 May 2019 in Molecular Psychiatry
Verified
Journal Article
Closed access
PDF file
DAD. S. Albrecht
D. S. Albrecht
MKM. Kim
M. Kim
OAOluwaseun Akeju
Oluwaseun Akeju
ATAngel Torrado-Carvajal
Angel Torrado-Carvajal
RER. R. Edwards
R. R. Edwards
MLM. L. Loggia
M. L. Loggia

19 June 2014 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
YEYigitcan Eryaman
Yigitcan Eryaman
BGBastien Guerin
Bastien Guerin
CACan Akgun
Can Akgun
JHJOAQUIN L. HERRAIZ
JOAQUIN L. HERRAIZ
AMAdrian Martin
Adrian Martin
LWLawrence L. Wald
Lawrence L. Wald
Purpose Specific absorption rate (SAR) amplification around active implantable medical devices during diagnostic MRI procedures poses a potential risk for patient safety. In this study, we present a parallel transmit (pTx) strategy that can be used to safely scan patients with deep brain stimulation (DBS) implants. Methods We performed electromagnetic simulations at 3T using a uniform phantom and a multitissue realistic head model with a generic DBS implant. Our strategy is based on using implant‐friendly modes, which are defined as the modes of an array that reduce the local SAR around the DBS lead tip. These modes are used in a spokes pulse design algorithm in order to produce highly uniform magnitude least‐squares flip angle excitations. Results Local SAR (1 g) at the lead tip is reduced below 0.1 W/kg compared with 31.2 W/kg, which is obtained by a simple quadrature birdcage excitation without any sort of SAR mitigation. For the multitissue realistic head model, peak 10 g local SAR and global SAR are obtained as 4.52 W/kg and 0.48 W/kg, respectively. A uniform axial flip angle is also obtained (NRMSE <3%). Conclusion Parallel transmit arrays can be used to generate implant‐friendly modes and to reduce SAR around DBS implants while constraining peak local SAR and global SAR and maximizing flip angle homogeneity. Magn Reson Med 73:1896–1903, 2015.