Maria Teresa López

Maria Teresa López


Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 October 2017 in Sensors
Verified
Journal Article
Open access
PDF file
RZRoberto Zangroniz
Roberto Zangroniz
AMArturo Martinez-Rodrigo
Arturo Martinez-Rodrigo
JPJose M. Pastor
Jose M. Pastor
MLMaria Teresa López
Maria Teresa López
Antonio Fernández-CaballeroAntonio Fernández-Caballero
Antonio Fernández-Caballero
This article introduces a new and unobtrusive wearable monitoring device based on electrodermal activity (EDA) to be used in health-related computing systems. This paper introduces the description of the wearable device capable of acquiring the EDA of a subject in order to detect his/her calm/distress condition from the acquired physiological signals. The lightweight wearable device is placed in the wrist of the subject to allow continuous physiological measurements. With the aim of validating the correct operation of the wearable EDA device, pictures from the International Affective Picture System are used in a control experiment involving fifty participants. The collected signals are processed, features are extracted and a statistical analysis is performed on the calm/distress condition classification. The results show that the wearable device solely based on EDA signal processing reports around 89% accuracy when distinguishing calm condition from distress condition.

1 December 2016 in Journal of Biomedical Informatics
Verified
Journal Article
Closed access
Antonio Fernández-CaballeroAntonio Fernández-Caballero
Antonio Fernández-Caballero
AMArturo Martinez-Rodrigo
Arturo Martinez-Rodrigo
JPJose M. Pastor
Jose M. Pastor
José Carlos CastilloJosé Carlos Castillo
José Carlos Castillo
ELElena Lozano-Monasor
Elena Lozano-Monasor
AFAlicia Fernández-Sotos
Alicia Fernández-Sotos

5 January 2018 in Applied Sciences
Verified
Journal Article
Open access
PDF file
RZRoberto Zangroniz
Roberto Zangroniz
AMArturo Martinez-Rodrigo
Arturo Martinez-Rodrigo
MLMaria Teresa López
Maria Teresa López
JPJose M. Pastor
Jose M. Pastor
Antonio Fernández-CaballeroAntonio Fernández-Caballero
Antonio Fernández-Caballero
This paper introduces the design of a new wearable photoplethysmography (PPG) sensor and its assessment for mental distress estimation. In our design, a PPG sensor obtains blood volume information by means of an optical plethysmogram technique. A number of temporal, morphological and frequency markers are computed using time intervals between adjacent normal cardiac cycles to characterize pulse rate variability (PRV). In order to test the efficiency of the developed wearable for classifying distress versus calmness, the well-known International Affective Picture System has been used to induce different levels of arousal in forty-five healthy participants. The obtained results have shown that temporal features present a single discriminant power between emotional states of calm and stress, ranging from 67 to 72%. Moreover, a discriminant tree-based model is used to assess the possible underlying relationship among parameters. In this case, the combination of temporal parameters reaches 82.35% accuracy. Considering the low difficulty of metrics and methods used in this work, the algorithms are prepared to be embedded into a micro-controller device to work in real-time and in a long-term fashion.

1 November 2006 in Pattern Recognition
Verified
Journal Article
Closed access
MLMaria Teresa López
Maria Teresa López
Antonio Fernández-CaballeroAntonio Fernández-Caballero
Antonio Fernández-Caballero
MFMiguel A. Fernández
Miguel A. Fernández
JMJosé Mira
José Mira
ADAna E. Delgado
Ana E. Delgado

3 December 2018 in Electronics
Verified
Journal Article
Open access
PDF file
Roberto Sanchez-ReolidRoberto Sanchez-Reolid
Roberto Sanchez-Reolid
Arturo S. GarcíaArturo S. García
Arturo S. García
MVMiguel A. Vicente-Querol
Miguel A. Vicente-Querol
LFLuz Fernandez-Aguilar
Luz Fernandez-Aguilar
MLMaria Teresa López
Maria Teresa López
PGPascual González
Pascual González
Estimation of human emotions plays an important role in the development of modern brain-computer interface devices like the Emotiv EPOC+ headset. In this paper, we present an experiment to assess the classification accuracy of the emotional states provided by the headset’s application programming interface (API). In this experiment, several sets of images selected from the International Affective Picture System (IAPS) dataset are shown to sixteen participants wearing the headset. Firstly, the participants’ responses in form of a self-assessment manikin questionnaire to the emotions elicited are compared with the validated IAPS predefined valence, arousal and dominance values. After statistically demonstrating that the responses are highly correlated with the IAPS values, several artificial neural networks (ANNs) based on the multilayer perceptron architecture are tested to calculate the classification accuracy of the Emotiv EPOC+ API emotional outcomes. The best result is obtained for an ANN configuration with three hidden layers, and 30, 8 and 3 neurons for layers 1, 2 and 3, respectively. This configuration offers 85% classification accuracy, which means that the emotional estimation provided by the headset can be used with high confidence in real-time applications that are based on users’ emotional states. Thus the emotional states given by the headset’s API may be used with no further processing of the electroencephalogram signals acquired from the scalp, which would add a level of difficulty.

27 February 2017 in Journal of Ambient Intelligence and Humanized Computing
Verified
Journal Article
Closed access
PDF file
ELElena Lozano-Monasor
Elena Lozano-Monasor
MLMaria Teresa López
Maria Teresa López
FVFrancisco Vigo-Bustos
Francisco Vigo-Bustos
Antonio Fernández-CaballeroAntonio Fernández-Caballero
Antonio Fernández-Caballero