Arturo Martinez-Rodrigo

Dr. Arturo Martinez-Rodrigo

Universidad de Castilla-La Mancha, Cuenca, Spain
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 October 2017 in Sensors
Verified
Journal Article
Open access
PDF file
RZRoberto Zangroniz
Roberto Zangroniz
AMArturo Martinez-Rodrigo
Arturo Martinez-Rodrigo
JPJose M. Pastor
Jose M. Pastor
MLMaria Teresa López
Maria Teresa López
Antonio Fernández-CaballeroAntonio Fernández-Caballero
Antonio Fernández-Caballero
This article introduces a new and unobtrusive wearable monitoring device based on electrodermal activity (EDA) to be used in health-related computing systems. This paper introduces the description of the wearable device capable of acquiring the EDA of a subject in order to detect his/her calm/distress condition from the acquired physiological signals. The lightweight wearable device is placed in the wrist of the subject to allow continuous physiological measurements. With the aim of validating the correct operation of the wearable EDA device, pictures from the International Affective Picture System are used in a control experiment involving fifty participants. The collected signals are processed, features are extracted and a statistical analysis is performed on the calm/distress condition classification. The results show that the wearable device solely based on EDA signal processing reports around 89% accuracy when distinguishing calm condition from distress condition.

1 December 2016 in Journal of Biomedical Informatics
Verified
Journal Article
Closed access
Antonio Fernández-CaballeroAntonio Fernández-Caballero
Antonio Fernández-Caballero
AMArturo Martinez-Rodrigo
Arturo Martinez-Rodrigo
JPJose M. Pastor
Jose M. Pastor
José Carlos CastilloJosé Carlos Castillo
José Carlos Castillo
ELElena Lozano-Monasor
Elena Lozano-Monasor
AFAlicia Fernández-Sotos
Alicia Fernández-Sotos

24 September 2010 in Physiological Measurement
Verified
Journal Article
Closed access
AMArturo Martinez-Rodrigo
Arturo Martinez-Rodrigo
RMRaul Alcaraz Martinez
Raul Alcaraz Martinez
José J. RietaJosé J. Rieta
José J. Rieta
This work introduces a new single-lead ECG delineator based on phasor transform. The method is characterized by its robustness, low computational cost and mathematical simplicity. It converts each instantaneous ECG sample into a phasor, and can precisely manage P and T waves, which are of notably lower amplitude than the QRS complex. The method has been validated making use of synthesized and real ECG sets, including the MIT-BIH arrhythmia, QT, European ST-T and TWA Challenge 2008 databases. Experiments with the synthesized recordings reported precise detection and delineation performances in a wide variety of ECGs, with signal-to-noise ratios of 10 dB and above. For real ECGs, the QRS detection was characterized by an average sensitivity of 99.81% and positive predictivity of 99.89%, for all the analyzed databases (more than one million beats). Regarding delineation, the maximum localization error between automatic and manual annotations was lower than 6 ms and its standard deviation was in agreement with the accepted tolerances for expert physicians in the onset and offset identification for QRS, P and T waves. Furthermore, after revising and reannotating some ECG recordings by expert cardiologists, the delineation error decreased notably, becoming lower than 3.5 ms, on average, and reducing by a half its standard deviation. This new proposed strategy outperforms the results provided by other well-known delineation algorithms and, moreover, presents a notably lower computational cost.

1 May 2000 in Robotica
Verified
Journal Article
Closed access
PDF file
CBC. Balaguer
C. Balaguer
AGAntonio Gimenez
Antonio Gimenez
JPJose M. Pastor
Jose M. Pastor
VPV. M. Padrón
V. M. Padrón
Mohamed AbderrahimMohamed Abderrahim
Mohamed Abderrahim
Often inspection and maintenance work involve a large number of highly dangerous manual operations, especially within industrial fields such as shipbuilding and construction. This paper deals with the autonomous climbing robot which uses the “caterpillar” concept to climb in complex 3D metallic-based structures. During its motion the robot generates in real-time the path and grasp planning in order to ensure stable self-support to avoid the environment obstacles, and to optimise the robot consumption during the inspection. The control and monitoring of the robot is achieved through an advanced Graphical User Interface to allow an effective and user friendly operation of the robot. The experiments confirm its advantages in executing the inspection operations.

1 January 2019 in IEEE Transactions on Affective Computing
Verified
Journal Article
Closed access
BMBeatriz Garcia Martinez
Beatriz Garcia Martinez
AMArturo Martinez-Rodrigo
Arturo Martinez-Rodrigo
RMRaul Alcaraz Martinez
Raul Alcaraz Martinez
Antonio Fernández-CaballeroAntonio Fernández-Caballero
Antonio Fernández-Caballero
Electroencephalographic (EEG) recordings are receiving growing attention in the field of emotion recognition, since they monitor the brain's first response to an external stimulus. Traditionally, EEG signals have been studied from a linear viewpoint by means of statistical and frequency features. Nevertheless, given that the brain follows a completely nonlinear and nonstationary behavior, linear metrics present certain important limitations. In this sense, the use of nonlinear methods has recently revealed new information that may help understanding how the brain works under a series of emotional states. Hence, this paper summarizes the most recent works that have applied nonlinear methods in EEG signal analysis to emotion recognition. This paper also identifies some nonlinear indices that have not yet been employed in this research area.

3 June 2016 in Entropy
Verified
Journal Article
Open access
PDF file
BMBeatriz Garcia Martinez
Beatriz Garcia Martinez
AMArturo Martinez-Rodrigo
Arturo Martinez-Rodrigo
RZRoberto Zangroniz
Roberto Zangroniz
JPJose M. Pastor
Jose M. Pastor
RMRaul Alcaraz Martinez
Raul Alcaraz Martinez
Recognition of emotions is still an unresolved challenge, which could be helpful to improve current human-machine interfaces. Recently, nonlinear analysis of some physiological signals has shown to play a more relevant role in this context than their traditional linear exploration. Thus, the present work introduces for the first time the application of three recent entropy-based metrics: sample entropy (SE), quadratic SE (QSE) and distribution entropy (DE) to discern between emotional states of calm and negative stress (also called distress). In the last few years, distress has received growing attention because it is a common negative factor in the modern lifestyle of people from developed countries and, moreover, it may lead to serious mental and physical health problems. Precisely, 279 segments of 32-channel electroencephalographic (EEG) recordings from 32 subjects elicited to be calm or negatively stressed have been analyzed. Results provide that QSE is the first single metric presented to date with the ability to identify negative stress. Indeed, this metric has reported a discriminant ability of around 70%, which is only slightly lower than the one obtained by some previous works. Nonetheless, discriminant models from dozens or even hundreds of features have been previously obtained by using advanced classifiers to yield diagnostic accuracies about 80%. Moreover, in agreement with previous neuroanatomy findings, QSE has also revealed notable differences for all the brain regions in the neural activation triggered by the two considered emotions. Consequently, given these results, as well as easy interpretation of QSE, this work opens a new standpoint in the detection of emotional distress, which may gain new insights about the brain’s behavior under this negative emotion.