Background Brain biopsy of intracranial lesions is often necessary to determine specific therapy. The cost of the currently used stereotactic rigid frame and optical tracking systems for brain biopsy in dogs is often prohibitive or accuracy is not sufficient for all types of lesion. Objectives To evaluate the application accuracy of an inexpensive magnetic resonance imaging‐based personalized, 3D printed brain biopsy device. Animals Twenty‐two dog heads from cadavers were separated into 2 groups according to body weight (20 kg). Methods Experimental study. Two target points in each cadaver head were used (target point 1: caudate nucleus, target point 2: piriform lobe). Comparison between groups was performed using the independent Student's t test or the nonparametric Mann‐Whitney U Test. Results The total median target point deviation was 0.83 mm (range 0.09‐2.76 mm). The separate median target point deviations for target points 1 and 2 in all dogs were 0.57 mm (range: 0.09‐1.25 mm) and 0.85 mm (range: 0.14‐2.76 mm), respectively. Conclusion and Clinical Importance This magnetic resonance imaging‐based 3D printed stereotactic brain biopsy device achieved an application accuracy that was better than the accuracy of most brain biopsy systems that are currently used in veterinary medicine. The device can be applied to every size and shape of skull and allows precise positioning of brain biopsy needles in dogs.
Localization of features and structures in images is an important task in medical image-processing. Characteristic structures and features are used in diagnostics and surgery planning for spatial adjustments of the volumetric data, including image registration or localization of bone-anchors and fiducials. Since this task is highly recurrent, a fast, reliable and automated approach without human interaction and parameter adjustment is of high interest. In this paper we propose and compare four image processing pipelines, including algorithms for automatic detection and localization of spherical features within 3D MRI data. We developed a convolution based method as well as algorithms based on connected-components labeling and analysis and the circular Hough-transform. A blob detection related approach, analyzing the Hessian determinant, was examined. Furthermore, we introduce a novel spherical MRI-marker design. In combination with the proposed algorithms and pipelines, this allows the detection and spatial localization, including the direction, of fiducials and bone-anchors.
The use of stereotactic frames is a common practice in neurosurgical interventions such as brain biopsy and deep brain stimulation. However, conventional stereotactic frames have been shown to require modification and adaptation regarding patient and surgeon comfort as well as the increasing demand for individualized medical treatment. To meet these requirements for carrying out state-of-the-art neurosurgery, a 3D print-based, patient-specific stereotactic system was developed and examined for technical accuracy. Sixteen patient-specific frames, each with two target points, were additively manufactured from PA12 using the Multi Jet Fusion process. The 32 target points aim to maximize the variability of biopsy targets and depths for tissue sample retrieval in the brain. Following manufacturing, the frames were measured three-dimensionally using an optical scanner. The frames underwent an autoclave sterilization process prior to rescanning. The scan-generated models were compared with the planned CAD models and the deviation of the planned target points in the XY-plane, Z-direction and in the resulting direction were determined. Significantly lower (p < 0.01) deviations were observed when comparing CAD vs. print and print vs. sterile in the Z-direction (0.17 mm and 0.06 mm, respectively) than in the XY-plane (0.46 mm and 0.16 mm, respectively). The resulting target point deviation (0.51 mm) and the XY-plane (0.46 mm) are significantly higher (p < 0.01) in the CAD vs. print comparison than in the print vs. sterile comparison (0.18 mm and 0.16 mm, respectively). On average, the results from the 32 target positions examined exceeded the clinically required accuracy for a brain biopsy (2 mm) by more than four times. The patient-specific stereotaxic frames meet the requirements of modern neurosurgical navigation and make no compromises when it comes to accuracy. In addition, the material is suitable for autoclave sterilization due to resistance to distortion.
There is a wide spectrum of injuries and medical conditions that are treated with the use of orthoses. For better comfort fully customized orthoses are designed and manufactured via 3D-printing or thermoforming thermoplastic casts with a low glass transition and softening temperature nowadays. This study aims to print a planar orthosis design and then thermoform the orthotic blank with intrinsic heating to get the final customized design depending on patient's needs. After identifying possible thermoplastic polymers for the application with differential scanning calorimetry (DSC) to determine thermal properties, tensile testing for mechanical properties and peel-off testing to measure multi material printing adhesion, the final orthosis blank is printed using Wire-EncapsulatingAdditiveManufacturing to integrate heating wires into the structure and create the intrinsic ability of heat generation for the thermoforming process.
Background: Brain biopsy is required for the accurate specification and further diagnosis of intracranial findings. The conventional stereotactic frames are used clinically for biopsies and offer the highest possible precision. Unfortunately, they come with some insurmountable technical and logistical limitations. The aim of the present work is to determine the clinical precision in the needle biopsy of the human brain using a new patient-specific stereotactic navigation device based on 3D printing. Methods: MRI data sets of human cadaver heads were used to plan 32 intracranial virtual biopsy targets located in different brain regions. Based on these data, 16 individualized stereotactic frames were 3D-printed. After the intraoperative application of the stereotactic device to the cadaver’s head, the actual needle position was verified by postoperative CT. Results: Thirty-two brain areas were successfully biopsied. The target point accuracy was 1.05 ± 0.63 mm, which represents the difference between the planned and real target points. The largest target point deviation was in the coronal plane at 0.60 mm; the smallest was in the transverse plane (0.45 mm). Conclusions: Three-dimensional-printed, personalized stereotactic frames or platforms are an alternative to the commonly used frame-based and frameless stereotactic systems. They are particularly advantageous in terms of accuracy, reduced medical imaging, and significantly simplified intraoperative handling.