Additive manufacturing (AM) has emerged over the past four decades as a cost-effective, on-demand modality for fabrication of geometrically complex objects. The ability to design and print virtually any object shape using a diverse array of materials, such as metals, polymers, ceramics and bioinks, has allowed for the adoption of this technology for biomedical applications in both research and clinical settings. Current advancements in tissue engineering and regeneration, therapeutic delivery, medical device fabrication and operative management planning ensure that AM will continue to play an increasingly important role in the future of healthcare. In this review, we outline current biomedical applications of common AM techniques and materials.
The spine is the most common site of bone metastasis, often originating from prostate, lung, and breast cancers. High systemic doses of chemotherapeutics such as doxorubicin (DOX), cisplatin, or paclitaxel often have severe side effects. Surgical removal of spine metastases also leaves large defects which cannot spontaneously heal and require bone grafting. To circumvent these issues, we designed an approach for local chemotherapeutic delivery within 3D-printed scaffolds which could also potentially serve as a bone substitute. Direct treatment of prostate cancer cell line LAPC4 and patient derived spine metastases cells with 0.01 µM DOX significantly reduced metabolic activity, proliferation, migration, and spheroid growth. We then assessed uptake and release of DOX in a series of porous 3D-printed scaffolds on LAPC4 cells as well as patient-derived spine metastases cells. Over seven days, 60–75% of DOX loaded onto scaffolds could be released, which significantly reduced metabolic activity and proliferation of both LAPC4 and patient derived cells, while unloaded scaffolds had no effect. Porous 3D-printed scaffolds may provide a novel and inexpensive approach to locally deliver chemotherapeutics in a patient-specific manner at tumor resection sites. With a composite design to enhance strength and promote sustained drug release, the scaffolds could reduce systemic negative effects, enhance bone repair, and improve patient outcomes.
Study Design: Systematic review. Objective: To examine the relationship between the patient's preoperative expectations and short-term postoperative satisfaction and functional outcome in lumbar spine surgery. Methods: The Medline, Embase, and Cochrane databases were queried using a predefined search algorithm to identify all lumbar spine studies analyzing the influence of preoperative expectations on postoperative satisfaction and functional outcome. Two independent reviewers and a third independent mediator reviewed the literature and performed study screening, selection, methodological assessment, and data extraction using an objective protocol. Results: Of 444 studies identified, 13 met the inclusion criteria. Methodological quality scores ranged from 59 to 100% with the greatest variability in defining patient characteristics and the methods of assessing patient expectations. Patient expectations were assessed in 22 areas, most frequently back and leg pain expectations and general expectations. Functional outcome was assessed by 13 tools; the most common were the visual analog scale, Oswestry Disability Index (ODI), and Short Form Health Survey (SF-36). Positive expectations for symptomatology, activity, general health, and recovery correlated with satisfaction. General expectations correlated with higher SF-36 Physical Subcomponent scores, better global function, and lower ODI outcome. Conclusions on the influence of the expectations for pain were limited due to the study heterogeneity, but the evidence suggests a positive correlation between the expectation and outcome for back and leg pain. Conclusions: Positive expectations correlated significantly with short-term postoperative satisfaction and functional outcome, including higher SF-36 scores, earlier return to work, and decreased ODI scores. Future expectation-based investigations will benefit from implementation of the standardized methods of expectation, satisfaction, and outcome analysis discussed herein.
There is significant variability in minimal clinically important difference (MCID) criteria for lumbar spine surgery that suggests population and primary pathology specific thresholds may be required to help determine surgical success when using patient reported outcome measures (PROMs). The purpose of this study was to estimate MCID thresholds for three commonly used PROMs after surgical intervention for each of four common lumbar spine pathologies. Observational longitudinal study of patients from {BLINDED} national registry. Patients undergoing surgery from 2015-2018 for lumbar spinal stenosis (LSS; n=856), degenerative spondylolisthesis (DS; n=591), disc herniation (DH; n=520) or degenerative disc disease (DDD n=185) were included. PROMs were collected pre-surgery and one-year post-surgery: the Oswestry Disability Index (ODI), and back and leg Numeric Pain Rating Scales (NPRS). At 1-year, patients reported whether they were 'Much better'/'Better'/'Same'/'Worse'/'Much worse' compared to before their surgery. Responses to this item were used as the anchor in analyses to determine surgical MCIDs for benefit ('Much better'/'Better') and substantial benefit ('Much better'). MCIDs for absolute and percentage change for each of the three PROMs were estimated using a receiving operating curve (ROC) approach, with maximization of Youden's index as primary criterion. Area under the curve (AUC) estimates, sensitivity, specificity and correct classification rates were determined. All analyses were conducted separately by pathology group. MCIDs for ODI change ranged from -10.0 (DDD) to -16.9 (DH) for benefit, and -13.8 (LSS) to -22.0 (DS,DH) for substantial benefit. MCID for back and leg NPRS change were -2 to -3 for each group for benefit and -4.0 for substantial benefit for all groups on back NPRS. MCID estimates for percentage change varied by PROM and pathology group, ranging from -11.1% (ODI for DDD) to -50.0% (leg NPRS for DH) for benefit and from -40.0% (ODI for DDD) to -66.6% (leg NPRS for DH) for substantial benefit. Correct classification rates for all MCID thresholds ranged from 71%-89% and were relatively lower for absolute vs. percent change for those with high or low pre-surgical scores. Our findings suggest that the use of generic MCID thresholds across pathologies in lumbar spine surgery is not recommended. For patients with relatively low or high pre-surgery PROM scores, MCIDs based on percentage change, rather than absolute change, appear generally preferable. These findings have applicability in clinical and research settings, and are important for future surgical prognostic work.
The current gold standard technique for treatment of anterior cruciate ligament (ACL) injury is reconstruction with autograft. These treatments have a relatively high failure and re-tear rate. To overcome this, tissue engineering and additive manufacturing are being used to explore the potential of 3D scaffolds as autograft substitutes. However, mechanically optimal polymers for this have yet to be identified. Here, we use 3D printing technology and various materials with the aim of fabricating constructs better matching the mechanical properties of the native ACL. A fused deposition modeling (FDM) 3D printer was used to microfabricate dog bone-shaped specimens from six different polymers—PLA, PETG, Lay FOMM 60, NinjaFlex, NinjaFlex-SemiFlex, and FlexiFil—at three different raster angles. The tensile mechanical properties of these polymers were determined from stress–strain curves. Our results indicate that no single material came close enough to successfully match reported mechanical properties of the native ACL. However, PLA and PETG had similar ultimate tensile strengths. Lay FOMM 60 displayed a percentage strain at failure similar to reported values for native ACL. Furthermore, raster angle had a significant impact on some mechanical properties for all of the materials except for FlexiFil. We therefore conclude that while none of these materials alone is optimal for mimicking ACL mechanical properties, there may be potential for creating a 3D-printed composite constructs to match ACL mechanical properties. Further investigations involving co-printing of stiff and elastomeric materials must be explored.