Simone Castellan

Prof. Simone Castellan

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2018 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Closed access
SCSimone Castellan
Simone Castellan
RMRoberto Menis
Roberto Menis
ATAlberto Tessarolo
Alberto Tessarolo
FLFabio Luise
Fabio Luise
TMTeresa Mazzuca
Teresa Mazzuca

1 April 2013
Verified
Conference Paper
Closed access
ATA. Tessarolo
A. Tessarolo
SCSimone Castellan
Simone Castellan
RMR. Menis
R. Menis
SGSulligoi Giorgio
Sulligoi Giorgio
A promising solution to improve tomorrow's all-electric ship onboard power system design and performance relies on moving from 50-Hz or 60-Hz AC distribution to a Medium-Voltage DC (MVDC) grid. This paper provides a review of presently-available and under-development technologies for electric generators to be used in perspective MVDC shipboard systems. The inspiring reason for the survey lies in the fact that an MVDC grid design removes the constraints usually imposed on shipboard generation group design and opens the way for a wide variety of non-conventional machine alternatives. In combination of high-speed gas turbines, that can be employed as prime movers, several electric machine topologies, not yet used for ship applications, can be selected to feed MVDC onboard systems. Along with a review of possible generator types suitable for such use, the paper critically reviews some emerging technologies for their fault-tolerance enhancement through conventional and innovative split-phase architectures.

1 March 2014
Verified
Conference Paper
Closed access
SCSimone Castellan
Simone Castellan
RMRoberto Menis
Roberto Menis
ATAlberto Tessarolo
Alberto Tessarolo
SGSulligoi Giorgio
Sulligoi Giorgio
Integrated Power Systems (IPS) with DC distribution require the massive use of power electronics for many tasks: 1) the output voltage rectification of generators and the connection of energy storage systems to the IPS, 2) the supply of medium voltage high power users (propulsion drives, bow thrusters, compressors for air conditioning), 3) the adjustment of voltage levels, which is performed by power transformers in AC distribution systems and by DC/DC power converters called Solid-State Transformers (SST) in DC distribution systems. In this paper, an overview is given of the power converters found in the literature and on the market that could be suitable for employment in the mentioned subsystems as parts of a future MVDC IPS. Finally authors propose a structure for an SST to be employed in three-wire MVDC power systems.

1 May 2007
Verified
Conference Paper
Closed access
Alessandro Massi PavanAlessandro Massi Pavan
Alessandro Massi Pavan
SCSimone Castellan
Simone Castellan
SQS. Quaia
S. Quaia
SRS. Roitti
S. Roitti
SGSulligoi Giorgio
Sulligoi Giorgio
Photovoltaic (PV) plants in Italy are presently subject to a rapid increase due to recent government incentives dedicated to grid connected PV plants. Incentives are given on the basis of the energy actually delivered to the grid, so that it becomes fundamental for the owner to produce as much energy as possible in order to reduce the payback time. In this framework, PV system efficiency plays a fundamental role. This paper focuses on medium and large size PV power systems, for which plant efficiency becomes a key design issue. In particular, the choice between centralized or distributed ("string") architecture is analyzed in terms of plant efficiency, considering the following basic issues: (1) losses in the power electronic conditioning system; (2) losses due to cable dissipation; (3) losses due to possible maximum power point mismatch.

1 September 2009 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
ATAlberto Tessarolo
Alberto Tessarolo
SCSimone Castellan
Simone Castellan
RMRoberto Menis
Roberto Menis
GFGiancarlo Ferrari
Giancarlo Ferrari
Split-phase synchronous motors equipped with multiple-stator three-phase windings, each supplied by a load-commutated inverter, play an important role in today's very high power electrical-drive applications. A criticality of these systems is the possibility that commutations occur in different motor windings simultaneously. The resulting electromagnetic transient depends on the magnetic coupling of motor phases among them and with rotor circuits. In this paper, a model to describe this phenomenon is presented along with some dedicated tests, conducted on various split-phase configurations, to assess the model validity.

1 May 2007
Verified
Conference Paper
Closed access
SCSimone Castellan
Simone Castellan
RMR. Menis
R. Menis
MPM. Pigani
M. Pigani
SGSulligoi Giorgio
Sulligoi Giorgio
ATA. Tessarolo
A. Tessarolo
Electric propulsion for cruise liners has now become a standard owing to its several advantages. However propulsion drives have a large impact on the ship power system. This gives rise to the requirement for designers to understand in depth the effects of propulsion drives on the ship network in different operating conditions. For this purpose computer simulations have proved to be a very useful tool. In the paper a typical propulsion drive for an all-electric cruise liner is described and simulation results are shown. Owing to the model complexity, simulations turn out to be computationally quite heavy. For this reason a simplified model has been developed. Simulation results, from the ship network viewpoint, proved to be close to the detailed model ones.