Sripriya Nannu Shankar

Dr. Sripriya Nannu Shankar

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 August 2021 in Journal of Aerosol Science
Verified
Journal Article
Open access
Sripriya Nannu ShankarSripriya Nannu Shankar
Sripriya Nannu Shankar
CWChiran T. Witanachchi
Chiran T. Witanachchi
AMAlyssa F. Morea
Alyssa F. Morea
JLJohn A. Lednicky
John A. Lednicky
JLJulia C. Loeb
Julia C. Loeb
CWChang-Yu Wu
Chang-Yu Wu
Individuals with COVID-19 are advised to self-isolate at their residences unless they require hospitalization. Persons sharing a dwelling with someone who has COVID-19 have a substantial risk of being exposed to the virus. However, environmental monitoring for the detection of virus in such settings is limited. We present a pilot study on environmental sampling for SARS-CoV-2 virions in the residential rooms of two volunteers with COVID-19 who self-quarantined. Apart from standard surface swab sampling, based on availability, four air samplers positioned 0.3–2.2 m from the volunteers were used: a VIable Virus Aerosol Sampler (VIVAS), an inline air sampler that traps particles on polytetrafluoroethylene (PTFE) filters, a NIOSH 2-stage cyclone sampler (BC-251), and a Sioutas personal cascade impactor sampler (PCIS). The latter two selectively collect particles of specific size ranges. SARS-CoV-2 RNA was detected by real-time Reverse-Transcription quantitative Polymerase Chain Reaction (rRT-qPCR) analyses of particles in one air sample from the room of volunteer A and in various air and surface samples from that of volunteer B. The one positive sample collected by the NIOSH sampler from volunteer A's room had a quantitation cycle (Cq) of 38.21 for the N-gene, indicating a low amount of airborne virus [5.69E-02 SARS-CoV-2 genome equivalents (GE)/cm3 of air]. In contrast, air samples and surface samples collected off the mobile phone in volunteer B's room yielded Cq values ranging from 14.58 to 24.73 and 21.01 to 24.74, respectively, on the first day of sampling, indicating that this volunteer was actively shedding relatively high amounts of SARS-CoV-2 at that time. The SARS-CoV-2 GE/cm3 of air for the air samples collected by the PCIS was in the range 6.84E+04 to 3.04E+05 using the LED-N primer system, the highest being from the stage 4 filter, and similarly, ranged from 2.54E+03 to 1.68E+05 GE/cm3 in air collected by the NIOSH sampler. Attempts to isolate the virus in cell culture from the samples from volunteer B's room with the aforementioned Cq values were unsuccessful due to out-competition by a co-infecting Human adenovirus B3 (HAdVB3) that killed the Vero E6 cell cultures within 4 days of their inoculation, although Cq values of 34.56–37.32 were measured upon rRT-qPCR analyses of vRNA purified from the cell culture medium. The size distribution of SARS-CoV-2-laden aerosol particles collected from the air of volunteer B's room was >0.25 μm and >0.1 μm as recorded by the PCIS and the NIOSH sampler, respectively, suggesting a risk of aerosol transmission since these particles can remain suspended in air for an extended time and travel over long distances. The detection of virus in surface samples also underscores the potential for fomite transmission of SARS-CoV-2 in indoor settings.

1 February 2020 in Heliyon
Verified
Journal Article
Open access
NPN. K. Udaya Prakash
N. K. Udaya Prakash
JEJasmine Brighty Edwin
Jasmine Brighty Edwin
VRVidhya Rajagopal
Vidhya Rajagopal
Sripriya Nannu ShankarSripriya Nannu Shankar
Sripriya Nannu Shankar
BSBhuvaneswari Srinivasan
Bhuvaneswari Srinivasan
Coconut tree (Cocos nucifera L.), a perennial, monocot tree, belonging to the family Arecaceae, is distributed through the tropics. Bioactivities of coconut water, husk fiber, oil, flowers, spadix and mesocarp of coconut fruit are widely reported. However, there is no study on cotyledon of coconut. In this study, carbohydrates, proteins, lipids, phenols, flavonoids, tannins, alkaloids and antioxidants were quantified in hot and cold percolated extracts of coconut cotyledon. Further, the antioxidant activity was studied using 2,2-diphenyl-1-picrylhydrazyl (DPPH); ferric reducing antioxidant power (FRAP); ferric thiocyanate (FTC); thiobarbituric acid (TBA); nitric oxide (NO) radical scavenging and β-carotene bleaching assays. Among the secondary metabolites, only cardiac glycosides were detected. Methanolic extraction by cold percolation extracted high content of secondary metabolites and exhibited significant antioxidant activity in DPPH, FRAP, NO and β-carotene bleaching assays, with EC50 of 0.12, 6.43, 16.21 and 8.09 mg/ml respectively. The chloroform extracts recorded high lipid content and scavenged the radicals in FTC (EC50 13.31 mg/ml) and TBA (EC50 9.21 mg/ml) assays. The study recommends extraction of compounds using methanol through cold percolation. The cotyledon of coconut is found to be a potent nutritive source equivalent to the endosperm.

7 September 2023 in Aerosol Science and Technology
Verified
Journal Article
Open access
WVWilliam B. Vass
William B. Vass
Sripriya Nannu ShankarSripriya Nannu Shankar
Sripriya Nannu Shankar
JLJohn A. Lednicky
John A. Lednicky
YYYang Yang
Yang Yang
CMCarlos Manzanas
Carlos Manzanas
CWChang-Yu Wu
Chang-Yu Wu
Airborne transmission of infectious (viable) SARS-CoV-2 is increasingly accepted as the primary manner by which the virus is spread from person to person. Risk of exposure to airborne virus is higher in enclosed and poorly ventilated spaces. We present a study focused on air sampling within residences occupied by individuals with COVID-19. Air samplers (BioSpot-VIVAS, VIVAS, and BC-251) were positioned in primary- and secondary-occupancy regions in seven homes. Swab samples were collected from high-touch surfaces. Isolation of SARS-CoV-2 was attempted for samples with virus detectable by RT-qPCR. Viable virus was quantified by plaque assay, and complete virus genome sequences were obtained for selected samples from each sampling day. SARS-CoV-2 was detected in 24 of 125 samples (19.2%) by RT-qPCR and isolated from 14 (11.2%) in cell cultures. It was detected in 80.9% (17/21) and cultured from 61.9% (13/21) of air samples collected using water condensation samplers, compared to swab samples which had a RT-qPCR detection rate of 10.5% (4/38) and virus isolation rate of 2.63% (1/38). No statistically significant differences existed in the likelihood of virus detection by RT-qPCR or amount of infectious virus in the air between areas of primary and secondary occupancy within residences. Our work provides information about the presence of SARS-CoV-2 in the air within homes of individuals with COVID-19. Information herein can help individuals make informed decisions about personal exposure risks when sharing indoor spaces with infected individuals isolating at home and further inform health departments and the public about SARS-CoV-2 exposure risks within residences.

30 October 2024 in Journal of Hazardous Materials
Verified
Journal Article
Open access
AOAmber O’COnnor
Amber O’COnnor
ASAnna Villalobos Santeli
Anna Villalobos Santeli
Sripriya Nannu ShankarSripriya Nannu Shankar
Sripriya Nannu Shankar
ASAmin Shirkhani
Amin Shirkhani
Tracie BakerTracie Baker
Tracie Baker
Tara Sabo-AttwoodTara Sabo-Attwood
Tara Sabo-Attwood
There is growing concern surrounding the human health effects following inhalation exposure to microplastic fibers (MPFs). MPFs can harbor chemical additives, such as azobenzene disperse dyes (ADDs), that may contribute to their toxicity. The goal of this study was to determine the acute biological effects of dyed polyethylene terephthalate MPFs to fully differentiated normal human bronchial epithelial (NHBE) cells cultured at an air-liquid interface. Cells were exposed to 2000 undyed MPFs (84.80 µg/cm2) or 2000 dyed MPFs (129.86 µg/cm2) colored with a black dye stuff containing the dye Disperse Violet 93 (DV93) using a mesh hopper delivery device. Cells were also exposed to DV93 only (1 µg/mL). Results show that the dyed MPFs caused a more pronounced decrease in cell viability and transepithelial electrical resistance compared to undyed MPFs and unexposed control cells. Additionally, the DV93 and dyed MPFs significantly upregulated the mRNA expression of CYP1A1 and CYP1B1, which was not observed in the undyed MPF group. These results support the idea that components of MPFs, specifically azobenzene disperse dyes, can leach from MPFs in biological systems and exert unique toxicity profiles. This study emphasizes the importance of considering toxicity associated with both the fibers themselves and chemical leachates in future studies.

16 February 2024 in Aerosol Science and Technology
Verified
Journal Article
Closed access
YZYuetong Zhang
Yuetong Zhang
Sripriya Nannu ShankarSripriya Nannu Shankar
Sripriya Nannu Shankar
WVWilliam B. Vass
William B. Vass
JLJohn A. Lednicky
John A. Lednicky
Z. Hugh FanZ. Hugh Fan
Z. Hugh Fan
CWChang-Yu Wu
Chang-Yu Wu
As SARS-CoV-2 swept across the globe, increased ventilation and implementation of air cleaning were emphasized by the US CDC and WHO as important strategies to reduce the risk of inhalation exposure to the virus. To assess whether higher ventilation and air cleaning rates lead to lower exposure risk to SARS-CoV-2, 1274 manuscripts published between April 2020 and September 2022 were screened using key words "airborne SARS-CoV-2 or "SARS-CoV-2 aerosol". Ninety-three studies involved air sampling at locations with known sources (hospitals and residences) were selected and associated data were compiled. Two metrics were used to assess exposure risk: SARS-CoV-2 concentration and SARS-CoV-2 detection rate in air samples. Locations were categorized by type (hospital or residence) and proximity to the sampling location housing the isolated/quarantined patient (primary or secondary). The results showed that hospital wards had lower airborne virus concentrations than residential isolation rooms. A negative correlation was found between airborne virus concentrations in primary-occupancy areas and air changes per hour (ACH). In hospital settings, sample positivity rates were significantly reduced in secondary-occupancy areas compared to primary-occupancy areas, but they were similar across sampling locations in residential settings. ACH and sample positivity rates were negatively correlated, though the effect was diminished when ACH values exceeded 8. While limitations associated with diverse sampling protocols exist, data considered by this meta-analysis support the notion that higher ACH may reduce exposure risks to the virus in ambient air.

3 October 2024 in Aerosol Science and Technology
Verified
Journal Article
Open access
WVWilliam B. Vass
William B. Vass
ASAmin Shirkhani
Amin Shirkhani
MWMohammad Washeem
Mohammad Washeem
Sripriya Nannu ShankarSripriya Nannu Shankar
Sripriya Nannu Shankar
YZYuetong Zhang
Yuetong Zhang
CWChang-Yu Wu
Chang-Yu Wu
Exposure to airborne respiratory viruses can be a health hazard in occupational settings. In this study, air sampling was conducted from January to March 2023 in two outpatient medical clinics—one primary care clinic and one clinic dedicated to the diagnosis and treatment of respiratory illnesses—for the purpose of assessing airborne respiratory virus presence. Work involved the operation of a BioSpot-VIVAS™ as a stationary air sampler and deployment of NIOSH BC-251 bioaerosol samplers as either stationary devices or personal air samplers worn by staff members. Results were correlated with deidentified clinical data from patient testing. Samples from seven days were analyzed for SARS-CoV-2, influenza A H1N1 and H3N2 viruses, and influenza B Victoria- and Yamagata-lineage viruses, with an overall 17.5% (17/97) positivity rate. Airborne viruses predominated in particles of aerodynamic diameters from 1–4 μm and were recovered in similar quantities from both clinics. BC-251 samplers (17.4%, 15/86) and VIVAS (18.2%, 2/11) collected detectable viruses at similar rates, but more numerous BC-251 samplers provided greater insight into virus presence across clinical spaces and job categories. 60% of samples from reception areas contained detectable virus, and exposure to significantly more virus (p = 0.0028) occurred at reception desks as compared to the “mobile” job categories of medical providers and nurses. Overall, this study provides valuable insights into the impacts of hazard mitigation controls tailored to reducing respiratory virus exposure and highlights the need for continued diligence toward exposure risk mitigation in outpatient medical clinics.