Analina Emmanouil

Mrs. Analina Emmanouil

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 September 2022 in Biomechanics
Verified
Journal Article
Open access
PDF file
AFApostolina Foskolou
Apostolina Foskolou
AEAnalina Emmanouil
Analina Emmanouil
KBKonstantinos Boudolos
Konstantinos Boudolos
Elissavet N. RousanoglouElissavet N. Rousanoglou
Elissavet N. Rousanoglou
In popular fitness modalities, the participants often perform abdominal breathing while maintaining stable or rather unstable as well as inverted body stances that may challenge the respiratory muscles’ activation. This study aimed to examine the abdominal breathing effect on postural stability and the respiratory muscles’ activation during four body stances: the Upright Stance, the Quadrupled Inverted V, the Elbow Side-Bridge, and the Headstand. Participants (n = 29) maintained (40 s) the body stances under regular and abdominal breathing (the latter verified through visual inspection and 3D inertial sensing of the abdominal wall angular displacements, LORD-MicroStrain®, 100 Hz, MicroStrain, Inc., Williston, VT, USA). The trajectory of the center of pressure (CoP) (Kistler force plate, 100 Hz, Kistler Group, Winterthur, Switzerland) was recorded in synchronization with the respiratory muscles’ (sternocleidomastoid, external intercostals, diaphragm, rectus abdominis) vibromyographic activation (Biopac VMG sensors, 2000 Hz, Biopac Systems, Inc., Santa Barbara, CA, USA). Abdominal breathing had a significant (p ≤ 0.05) deteriorating effect on postural stability and an increasing one on the respiratory muscles’ activation; however, this was not consistent across body stances. The body stance specificity of the abdominal breathing effect justifies the purpose of the present study. Thus, before the request for abdominal breathing in popular fitness modalities, one should acknowledge the postural and the breathing demands of each particular stance, particularly for the inverted ones.

2 February 2024 in Biomechanics
Verified
Journal Article
Open access
PDF file
Elissavet N. RousanoglouElissavet N. Rousanoglou
Elissavet N. Rousanoglou
AFApostolina Foskolou
Apostolina Foskolou
AEAnalina Emmanouil
Analina Emmanouil
KBKonstantinos Boudolos
Konstantinos Boudolos
Head standing (HS) in concurrence with diaphragmatic breathing is an atypical deviation from daily activity, yet commonly practiced. The study aimed at the inertially sensed effect of diaphragmatic versus normal breathing on the abdomen wall kinematics during HS. Twenty-eight men and women maintained HS and erect standing (ES) under normal and diaphragmatic breathing. An inertial sensor (LORD MicroStrain®, 3DM-GX3®-45, 2 cm above the umbilicus, 100 Hz, MicroStrain, Williston, VT, USA) recorded the 3D abdomen wall angular displacement (AD) (bandpass filter (0.1–0.5 Hz)). ANOVAs (p ≤ 0.05, SPSS 28.0) were applied to the extracted variables (AD path: magnitude, individual variability-%CVind, and diaphragmatic to normal ratio). Reliability measures (ICC and %SEM) and the minimal detectable change (%MDC90) were estimated. Diaphragmatic breathing increased the AD path (p ≤ 0.05) with the diaphragmatic to normal ratio being lower in HS (p ≤ 0.05). The similar AD time series (cross-correlations at p ≤ 0.05) and the ICCs (>0.80) indicated excellent reliability with the similar across conditions %CVind (p ≤ 0.05), further enhancing reliability. The %MDC90 was consistently higher than the %SEM upper boundary, indicating the differences as “real” ones. The results contribute to the limited data concerning a widely practiced atypical deviation from daily activity, as HS in concurrence with diaphragmatic breathing.

23 March 2021 in Digital Biomarkers
Verified
Journal Article
Open access
PDF file
AEAnalina Emmanouil
Analina Emmanouil
ERElissavet Rousanoglou
Elissavet Rousanoglou
AGAnastasia Georgaki
Anastasia Georgaki
KBKonstantinos Boudolos
Konstantinos Boudolos
Introduction: The effect of rhythmic acoustic stimuli on body sway is of increasing interest due to their positive contribution when training or restoring the control of movement. Inertial sensors show promise as a portable, easier, and more affordable method compared to the force plate “gold standard” concerning the evaluation of postural sway. This study examined the concurrent validity of inertially sensed measures of voluntary body sway against those obtained with a force plate, in silence and while exposed to a rhythmic acoustic stimulus. Methods: Temporal (sway duration and variability) and spatial (trajectory length, variability, range, velocity, and area) body sway variables were extracted using an inertial sensor (at L5) in synchronization with a force plate, during anteroposterior body sway in silence and while exposed to a rhythmic acoustic stimulus (n = 18 young women; two 70-s trials in each condition). Statistics included bivariate correlations between the inertially sensed and the force plate measures, separately, in silence and with a rhythmic acoustic stimulus, as well as for the effect of the rhythmic acoustic stimulus (percentage difference from silence) (p ≤ 0.05, SPSS v25.0). Results: The inertially sensed measures demonstrated good-to-excellent concurrent validity for all temporal and almost all spatial variables, both in silence and with rhythmic acoustic stimulus (r > 0.75, p = 0.000), as well as for the rhythmic acoustic-stimulus effect (r > 0.75, p ≤ 0.05). Conclusion: The inertially sensed measures of the voluntary anteroposterior body sway demonstrated an overall good-to-excellent concurrent validity against those obtained with the force plate “gold standard,” both in the silence and the rhythmic acoustic stimulus conditions, as well as for the rhythmic acoustic-stimulus effect. The findings of this pilot study allow the recommendation of inertial sensing for the evaluation of postural control alterations when exposed to rhythmic acoustic stimuli, a condition of increasing interest due to the positive contribution of such stimuli when training or restoring the control of movement.

19 February 2024 in Biomechanics
Verified
Journal Article
Open access
PDF file
AEAnalina Emmanouil
Analina Emmanouil
Elissavet N. RousanoglouElissavet N. Rousanoglou
Elissavet N. Rousanoglou
KBKonstantinos Boudolos
Konstantinos Boudolos
This study aimed to determine the minimum number of repetitions for a high reliability of movement timing in fundamental physical fitness exercises using inertial sensors. Fifteen young men and fifteen women performed eight exercises (two-leg hop, forward lunge, squat, sit-up, shoulder abduction, hip abduction, back extension, and push-up) (preferred tempo, 3 trials, 20 repetitions per trial). The movement timing (cycle of movement in seconds and its phases in seconds and %tcycle) was tested for intra- and inter-trial reliability (SPSS 28.0, p ≤ 0.05). Just two repetitions were adequate for excellent intra- and inter-trial relative reliability (ICCs ≥ 0.75, isolated exceptions only for durations expressed as %tcycle, in only three out of the eight exercises: hip abduction, back extension, and push-up), as well as for high absolute intra- and inter-trial reliability (average SEM% at 5.9%, respectively, and 6.8% and average MDC95% at 13.7% and 15.9%, respectively, which was consistently higher than the upper boundary limit of SEM%, and a rather low CV% ranging from 1.5% to 4.9% and averaging at 3.1%). A total of four repetitions, excluding the initial and the final one, appears adequate for high overall reliability of movement timing in the eight physical fitness exercises examined.

8 August 2018 in Journal of Preventive Medicine And Care
Verified
Journal Article
Open access
PDF file
AEAnalina Emmanouil
Analina Emmanouil
Elissavet N. RousanoglouElissavet N. Rousanoglou
Elissavet N. Rousanoglou
KBKonstantinos D. Boudolos
Konstantinos D. Boudolos
Several studies examine the musculoskeletal pain (MSP) in university students sustaining physical load as part of their compulsory learning. However, only two somewhat outdated cross-sectional studies examine the physical education teacher (PET) students. This study aimed to explore the neck, shoulder and low back MSP prevalence in Greek PET students in a series of academic years. The Nordic Musculoskeletal Questionnaire was used to record the past 12-month neck, shoulder and, low back pain, across three academic years (n = 479). The year association to MSP prevalence was examined with the cross-tabulation analysis (using the column proportion test for the year comparison) and, the gender association to MSP prevalence with the χ2 test (SPSS 22.0, p ≤ 0.05). The year association to MSP prevalence was not significant (p > 0.05). The overall prevalence was 67.6%, with multiple pain at 25.7% and, the low back presenting the highest prevalence (40.9%). Women reported a higher prevalence of neck (36%) and low back (47%) pain (p ≤ 0.05). The majority of pain and time loss duration was 1-7 days. The low back required higher medical attention (19.0%) than the neck (9.2%) and the shoulder (12.9%). The recurrent pain was at 30%, with the previous injury/accident rate at 5.8%, 14.4% and 14.6% for the neck, shoulder and low back. Our PET students present an alarming MSP prevalence. Due to their distinct work demands as PE teachers, entering working life with the healthiest possible musculoskeletal system is of critical importance. Thus, university authorities should consider strategies for the prevention of MSP risk.

4 June 2026 in Sensors
Verified
Journal Article
Open access
PDF file
FPFani Panteri
Fani Panteri
AEAnalina Emmanouil
Analina Emmanouil
KBKonstantinos Boudolos
Konstantinos Boudolos
Elissavet N. RousanoglouElissavet N. Rousanoglou
Elissavet N. Rousanoglou
Wearable inertial sensors offer a portable alternative to laboratory-grade force plates for postural stability assessment; however, their validity across progressively challenging balance tasks remains under-explored. This study evaluated the reliability and concurrent validity of inertially sensed metrics compared with force-plate-derived postural sway metrics across a five-level spectrum of unstable surfaces (Floor, Foam Pad, Rotating Disc, Air Disc, Bosu). Twenty-five healthy young women (22.1 ± 3.6 years, 1.64 ± 0.04 m, 58.44 ± 8.21 kg) performed five trials of single-leg standing (40 s each) on each surface. Postural sway was computed from antero-posterior (AP) and medio-lateral (ML) center of pressure (CoP) recordings using a force plate (Kistler, 9286 AA, Winterthur, Switzerland, sampling at 500 Hz) in synchronization with a lateral shank-mounted inertial sensor (Bionomadix BN-ACCL3, Biopac Systems, Inc., Santa Barbara, CA, USA, sampling at 100 Hz). In addition to reliability, a two-tiered analysis evaluated global concordance (unstandardized slopes) and method agreement (standardized z-scores). Intraclass correlation coefficients (ICCs) for the inertial sensor were excellent (range: 0.95–0.96), surpassing the force plate (range: 0.85–0.92) as trials accumulated. Analysis revealed moderate-to-good global concordance in the AP direction (r = 0.60, p = 0.001) and good-to-excellent in the ML one (r = 0.85, p < 0.001), validating the progressive intensifying effect of the surface graduation. Individual ranking agreement—evaluated via standardized z-scores—was also significant in both the AP (r = 0.61, p < 0.001) and the ML (r = 0.85, p < 0.001) directions, indicating a convergence into how the two modalities rank individual performance. Bland–Altman plots confirmed high absolute agreement between standardized scores, though a predictable proportional bias was observed in raw units, where the inertial sensor’s underestimation of sway magnitude increased linearly with task difficulty. The five-level postural challenge graduation is a highly reliable framework for balance assessment. While the shank-mounted sensor exhibits proportional underestimation of sway magnitude compared to the CoP at extreme intensities, its high internal stability and sensitivity to task difficulty make it a valid and robust tool for longitudinal clinical monitoring.