Strain sensors, especially fiber Bragg grating (FBG) sensors, are of great importance in structural health monitoring, mechanical property analysis, and so on. Their metrological accuracy is typically evaluated by equal strength beams. The traditional strain calibration model using the equal strength beams was built based on an approximation method by small deformation theory. However, its measurement accuracy would be decreased while the beams are under the large deformation condition or under high temperature environments. For this reason, an optimized strain calibration model is developed for equal strength beams based on the deflection method. By combining the structural parameters of a specific equal strength beam and finite element analysis method, a correction coefficient is introduced into the traditional model, and an accurate application-oriented optimization formula is obtained for specific projects. The determination method of optimal deflection measurement position is also presented to further improve the strain calibration accuracy by error analysis of the deflection measurement system. Strain calibration experiments of the equal strength beam were carried out, and the error introduced by the calibration device can be reduced from 10 με to less than 1 με. Experimental results show that the optimized strain calibration model and the optimum deflection measurement position can be employed successfully under large deformation conditions, and the deformation measurement accuracy is improved greatly. This study is helpful to effectively establish metrological traceability for strain sensors and furthermore improve the measurement accuracy of strain sensors in practical engineering scenarious.
The flexible strain sensor’s measuring range is usually over 5000 με, while the conventional variable section cantilever calibration model has a measuring range within 1000 με. In order to satisfy the calibration requirements of flexible strain sensors, a new measurement model was proposed to solve the inaccurate calculation problem of the theoretical strain value when the linear model of a variable section cantilever beam was applied to a large range. The nonlinear relationship between deflection and strain was established. The finite element analysis of a variable section cantilever beam with ANSYS shows that the linear model’s relative deviation is as high as 6% at 5000 με, while the relative deviation of the nonlinear model is only 0.2%. The relative expansion uncertainty of the flexible resistance strain sensor is 0.365% (k = 2). Simulation and experimental results show that this method solves the imprecision of the theoretical model effectively and realizes the accurate calibration of a large range of strain sensors. The research results enrich the measurement models and calibration models for flexible strain sensors and contribute to the development of strain metering.
The tapping-mode atomic force microscope (TM-AFM) is widely used today; however, improper matching between the operating medium and the sampling time may lead to inaccurate measurement results. The relationship between the damping coefficient and the steady state of the TM-AFM microcantilever is investigated in this paper using multiple stability theory. Firstly, the effects of changes in dimensionless linear damping coefficients and dimensionless piezoelectric film damping coefficients on the motion stability of the system are examined using bifurcation diagrams, phase trajectories, and domains of attraction. Subsequently, the degrees of effect of the two damping coefficients on the stability of the system are compared. Finally, the bi-parametric bifurcation characteristics of the system under a specific number of iterative cycles are investigated using the bi-parametric bifurcation diagram in conjunction with the actual working conditions, and the boundary conditions for the transition of the system’s motion from an unstable state to a stable state are obtained. The results of the study show that to ensure the accuracy and reliability of the individual measurement data in 500 iteration cycles, the dimensionless linear damping coefficient must be greater than 0.01014. Our results will provide valuable references for TM-AFM measurement media selection, improving TM-AFM imaging quality, measurement accuracy and maneuverability, and TM-AFM troubleshooting.
Alterations in the dynamical properties of an atomic force microscope microcantilever beam system in tapping mode can appreciably impact its measurement precision. Understanding the influence mechanism of dynamic parameter changes on the system’s motion characteristics is vital to improve the accuracy of the atomic force microscope in tapping mode (AFM-TM). In this study, we categorize the mathematical model of the AFM-TM microcantilever beam system into systems 1 and 2 based on actual working conditions. Then, we analyze the alterations in the dynamic properties of both systems due to external excitation variations using bifurcation diagrams, phase trajectories, Lyapunov indices, and attraction domains. The numerical simulation results show that when the dimensionless external excitation g < 0.183, the motion state of system 2 is period 1. When g < 0.9, the motion state of system 1 is period 1 motion. Finally, we develop the equivalent circuit model of the AFM-TM microcantilever beam and perform related software simulations, along with practical circuit experiments. Our experimental results indicate that the constructed equivalent circuit can effectively analyze the dynamic characteristics of the AFM-TM microcantilever beam system in the presence of complex external environmental factors. It is observed that the practical circuit simulation attenuates high-frequency signals, resulting in a 31.4% reduction in excitation amplitude compared to numerical simulation results. This provides an essential theoretical foundation for selecting external excitation parameters for AFM-TM cantilever beams and offers a novel method for analyzing the dynamics of micro- and nanomechanical systems, as well as other nonlinear systems.
Optical image stabilization (OIS) is crucial for improving airborne opto-electronic imaging performance under dynamic conditions. This study presents a two-dimensional piezoelectric-driven OIS platform capable of compensating linear image shift errors. A motion platform integrating a bridge amplification mechanism and right-angle guiding beams was developed, and its theoretical model was validated through finite element analysis (FEA). To enhance the platform’s repeatability, the hysteresis of the piezoelectric actuator was described using the Bouc-Wen model, and was optimized using a Hybrid Genetic Algorithm and Particle Swarm Optimization (HGAPSO). Experimental results demonstrated that the platform achieves a workspace of 53.92 μm × 53.76 μm, a motion resolution of 30 nm, a maximum coupling error of 2.28%, and a first-order resonant frequency of 356.69 Hz. A composite controller incorporating HGAPSO attained submicron tracking accuracy, with errors of 0.43 μm and 0.47 μm along the X and Y axes, respectively. Strong agreement among theoretical analysis, FEA, and experimental results confirms the platform’s precision and effectiveness meeting the requirements of the OIS. This work provides valuable guidance for the development of high-frequency OIS systems in highly dynamic operational environments.