Strain sensors, especially fiber Bragg grating (FBG) sensors, are of great importance in structural health monitoring, mechanical property analysis, and so on. Their metrological accuracy is typically evaluated by equal strength beams. The traditional strain calibration model using the equal strength beams was built based on an approximation method by small deformation theory. However, its measurement accuracy would be decreased while the beams are under the large deformation condition or under high temperature environments. For this reason, an optimized strain calibration model is developed for equal strength beams based on the deflection method. By combining the structural parameters of a specific equal strength beam and finite element analysis method, a correction coefficient is introduced into the traditional model, and an accurate application-oriented optimization formula is obtained for specific projects. The determination method of optimal deflection measurement position is also presented to further improve the strain calibration accuracy by error analysis of the deflection measurement system. Strain calibration experiments of the equal strength beam were carried out, and the error introduced by the calibration device can be reduced from 10 με to less than 1 με. Experimental results show that the optimized strain calibration model and the optimum deflection measurement position can be employed successfully under large deformation conditions, and the deformation measurement accuracy is improved greatly. This study is helpful to effectively establish metrological traceability for strain sensors and furthermore improve the measurement accuracy of strain sensors in practical engineering scenarious.
The flexible strain sensor’s measuring range is usually over 5000 με, while the conventional variable section cantilever calibration model has a measuring range within 1000 με. In order to satisfy the calibration requirements of flexible strain sensors, a new measurement model was proposed to solve the inaccurate calculation problem of the theoretical strain value when the linear model of a variable section cantilever beam was applied to a large range. The nonlinear relationship between deflection and strain was established. The finite element analysis of a variable section cantilever beam with ANSYS shows that the linear model’s relative deviation is as high as 6% at 5000 με, while the relative deviation of the nonlinear model is only 0.2%. The relative expansion uncertainty of the flexible resistance strain sensor is 0.365% (k = 2). Simulation and experimental results show that this method solves the imprecision of the theoretical model effectively and realizes the accurate calibration of a large range of strain sensors. The research results enrich the measurement models and calibration models for flexible strain sensors and contribute to the development of strain metering.
Piezoelectric tilt mirrors are crucial components of precision optical systems. However, the intrinsic hysteretic nonlinearity of the piezoelectric actuator severely restricts the control accuracy of these mirrors and the overall performance of the optical system. This paper proposes an improved Gray Wolf Optimization (GWO) algorithm for high-accuracy identification of hysteresis model parameters based on the Bouc–Wen (BW) differential equation. The proposed algorithm accurately describes the intrinsic hysteretic nonlinear behavior of piezoelectric tilt mirrors. A logistic chaotic mapping method is introduced for population initialization, while a nonlinear convergence factor and a Levy flight strategy are incorporated to enhance global search capabilities during the later stages of optimization. These modifications enable the algorithm to effectively identify BW model parameters for piezoelectric nonlinear systems. Compared to conventional Particle Swarm Optimization (PSO) and standard GWO, the improved algorithm demonstrates faster convergence, higher accuracy, and superior ergodicity, making it a promising tool for solving optimization problems, such as parameter identification in piezoelectric hysteresis systems. This work provides a robust approach for improving the precision and reliability of piezoelectric-driven optical systems.
The tapping-mode atomic force microscope (TM-AFM) is widely used today; however, improper matching between the operating medium and the sampling time may lead to inaccurate measurement results. The relationship between the damping coefficient and the steady state of the TM-AFM microcantilever is investigated in this paper using multiple stability theory. Firstly, the effects of changes in dimensionless linear damping coefficients and dimensionless piezoelectric film damping coefficients on the motion stability of the system are examined using bifurcation diagrams, phase trajectories, and domains of attraction. Subsequently, the degrees of effect of the two damping coefficients on the stability of the system are compared. Finally, the bi-parametric bifurcation characteristics of the system under a specific number of iterative cycles are investigated using the bi-parametric bifurcation diagram in conjunction with the actual working conditions, and the boundary conditions for the transition of the system’s motion from an unstable state to a stable state are obtained. The results of the study show that to ensure the accuracy and reliability of the individual measurement data in 500 iteration cycles, the dimensionless linear damping coefficient must be greater than 0.01014. Our results will provide valuable references for TM-AFM measurement media selection, improving TM-AFM imaging quality, measurement accuracy and maneuverability, and TM-AFM troubleshooting.
This paper considers tracking control of non-affine pure-feedback systems with uncertain disturbances. The “explosion of complexity” in the process of backstepping design is eliminated by introducing the output of first-order filter to replace the derivative of virtual control signal. The mean-value theorem is utilized to overcome the non-affine difficulties appearing from the pure-feedback systems. By employing fuzzy logic systems (FLSs) and dynamic surface approach, an adaptive fuzzy controller with only one adaptive parameter is presented. Stability analysis shows that the proposed control method guarantees that all closed-loop system signals are semi-globally uniformly ultimately bounded. The main innovations of this paper are that the final gain function is viewed as an adjustable constant gain in the procedure of actual control signal design and the FLSs only handle state errors and disturbances. The new controller not only has the advantages of tracking performance, but it also reduces the computational burden in comparison with traditional adaptive backstepping method whose FLSs need to tackle with all gain function and system dynamics. A comparison simulation example shows the effectiveness of the proposed controller.
Alterations in the dynamical properties of an atomic force microscope microcantilever beam system in tapping mode can appreciably impact its measurement precision. Understanding the influence mechanism of dynamic parameter changes on the system’s motion characteristics is vital to improve the accuracy of the atomic force microscope in tapping mode (AFM-TM). In this study, we categorize the mathematical model of the AFM-TM microcantilever beam system into systems 1 and 2 based on actual working conditions. Then, we analyze the alterations in the dynamic properties of both systems due to external excitation variations using bifurcation diagrams, phase trajectories, Lyapunov indices, and attraction domains. The numerical simulation results show that when the dimensionless external excitation g < 0.183, the motion state of system 2 is period 1. When g < 0.9, the motion state of system 1 is period 1 motion. Finally, we develop the equivalent circuit model of the AFM-TM microcantilever beam and perform related software simulations, along with practical circuit experiments. Our experimental results indicate that the constructed equivalent circuit can effectively analyze the dynamic characteristics of the AFM-TM microcantilever beam system in the presence of complex external environmental factors. It is observed that the practical circuit simulation attenuates high-frequency signals, resulting in a 31.4% reduction in excitation amplitude compared to numerical simulation results. This provides an essential theoretical foundation for selecting external excitation parameters for AFM-TM cantilever beams and offers a novel method for analyzing the dynamics of micro- and nanomechanical systems, as well as other nonlinear systems.