Kamila Iskhakova

Mrs. Kamila Iskhakova


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 September 2021 in Metals
Verified
Journal Article
Open access
PDF file
SMSebastian Meyer
Sebastian Meyer
AWAndreas Wolf
Andreas Wolf
DSDaniela Sanders
Daniela Sanders
KIKamila Iskhakova
Kamila Iskhakova
HĆHanna Ćwieka
Hanna Ćwieka
BZBerit Zeller-Plumhoff
Berit Zeller-Plumhoff
Magnesium–silver alloys are of high interest for the use as temporary bone implants due to their antibacterial properties in addition to biocompatibility and biodegradability. Thin wires in particular can be used for scaffolding, but the determination of their degradation rate and homogeneity using traditional methods is difficult. Therefore, we have employed 3D imaging using X-ray near-field holotomography with sub-micrometer resolution to study the degradation of thin (250 μm diameter) Mg-2Ag and Mg-6Ag wires. The wires were studied in two states, recrystallized and solution annealed to assess the influence of Ag content and precipitates on the degradation. Imaging was employed after degradation in Dulbecco’s modified Eagle’s medium and 10% fetal bovine serum after 1 to 7 days. At 3 days of immersion the degradation rates of both alloys in both states were similar, but at 7 days higher silver content and solution annealing lead to decreased degradation rates. The opposite was observed for the pitting factor. Overall, the standard deviation of the determined parameters was high, owing to the relatively small field of view during imaging and high degradation inhomogeneity of the samples. Nevertheless, Mg-6Ag in the solution annealed state emerges as a potential material for thin wire manufacturing for implants.

1 July 2023 in Bioactive Materials
Verified
Journal Article
Open access
JEJonathan Espiritu
Jonathan Espiritu
MBMostafa Berangi
Mostafa Berangi
HCHanna Cwieka
Hanna Cwieka
KIKamila Iskhakova
Kamila Iskhakova
AKAndre Kuehne
Andre Kuehne
JSJan-Marten Seitz
Jan-Marten Seitz
Magnesium (Mg)-based implants have re-emerged in orthopaedic surgery as an alternative to permanent implants. Literature reveals little information on how the degradation of biodegradable implants may introduce safety implications for patient follow-up using medical imaging. Magnetic resonance imaging (MRI) benefits post-surgery monitoring of bone healing and implantation sites. Previous studies demonstrated radiofrequency (RF) heating of permanent implants caused by electromagnetic fields used in MRI. Our investigation is the first to report the effect of the degradation layer on RF-induced heating of biodegradable orthopaedic implants. WE43 orthopaedic compression screws underwent in vitro degradation. Imaging techniques were applied to assess the corrosion process and the material composition of the degraded screws. Temperature measurements were performed to quantify implant heating with respect to the degradation layer. For comparison, a commercial titanium implant screw was used. Strongest RF induced heating was observed for non-degraded WE43 screw samples. Implant heating had shown to decrease with the formation of the degradation layer. No statistical differences were observed for heating of the non-degraded WE43 material and the titanium equivalent. The highest risk of implant RF heating is most pronounced for Mg-based screws prior to degradation. Amendment to industry standards for MRI safety assessment is warranted to include biodegradable materials.

1 November 2024 in Bioactive Materials
Verified
Journal Article
Open access
KIKamila Iskhakova
Kamila Iskhakova
HCHanna Cwieka
Hanna Cwieka
SMSvenja Meers
Svenja Meers
HHHeike Helmholz
Heike Helmholz
Anton DavydokAnton Davydok
Anton Davydok
RWRegine Willumeit
Regine Willumeit
Magnesium (Mg) - based alloys are becoming attractive materials for medical applications as temporary bone implants for support of fracture healing, e.g. as a suture anchor. Due to their mechanical properties and biocompatibility, they may replace titanium or stainless-steel implants, commonly used in orthopedic field. Nevertheless, patient safety has to be assured by finding a long-term balance between metal degradation, osseointegration, bone ultrastructure adaptation and element distribution in organs. In order to determine the implant behavior and its influence on bone and tissues, we investigated two Mg alloys with gadolinium contents of 5 and 10 wt percent in comparison to permanent materials titanium and polyether ether ketone. The implants were present in rat tibia for 10, 20 and 32 weeks before sacrifice of the animal. Synchrotron radiation-based micro computed tomography enables the distinction of features like residual metal, degradation layer and bone structure. Additionally, X-ray diffraction and X-ray fluorescence yield information on parameters describing the bone ultrastructure and elemental composition at the bone-to-implant interface. Finally, with element specific mass spectrometry, the elements and their accumulation in the main organs and tissues are traced. The results show that Mg-xGd implants degrade in vivo under the formation of a stable degradation layer with bone remodeling similar to that of Ti after 10 weeks. No accumulation of Mg and Gd was observed in selected organs, except for the interfacial bone after 8 months of healing. Thus, we confirm that Mg-5Gd and Mg-10Gd are suitable material choices for bone implants.

14 November 2025 in Materials Advances
Verified
Journal Article
Open access
PDF file
AMArmando Mandlule
Armando Mandlule
YLYue Liu
Yue Liu
SSSusanne Schwanz
Susanne Schwanz
YPYvonne Pieper
Yvonne Pieper
HSHeike Scharf
Heike Scharf
ANAxel T. Neffe
Axel T. Neffe
In phase-separating multiblock copolymers it is a challenge to quantify the relationship between molecular structure and functional properties, yet this quantification is crucial for processing and applications. Here, we describe the molecular structure and phase behavior-properties relationships for a modular system of poly[(ε-caprolactone)-b-poly(L-lactide)] multiblock copolymers with well-defined long/short block lengths and their blends with Poly(D-lactide) (PDLA) of varying lengths. The formation of crystallite types and sizes as well as absolute and relative crystallinities of PCL, PLA homocrystallites (HC), and PLA stereocrystallites (SC) were studied by DSC and WAXS, and visualized by TEM, POM, and AFM. We reveal that SC formation occurs in blends containing between a 1:1 and 1:4 ratio between PDLA and PLLA. In systems with much longer PCL than PLLA sequence length (113:18), SC formation is inhibited. Blend crystallinity was highest for a medium PDLA length. SC formation is preferred over HC formation, and SCs act as nucleation points for PCL crystallization. In our work the segment length had a trend to correlate with crystallite sizes. Tensile strength (from 0.5 to 8 MPa) and elongation at break (from 10% to >750% at room temperature) could be increased simultaneously by allowing SC formation, which in the studied blends correlated with low overall crystallinity. Our study shows strategic polymer synthesis and blending for the precise control of stereocomplex formation and fine-tuning in high-performance PLA-based materials. These findings support the knowledge-based choice of blend composition and segment length to tailor versatile materials with tunable mechanical and thermal properties.

Verified
Journal Article
Open access
PDF file
KIKamila Iskhakova
Kamila Iskhakova
FWFlorian Wieland
Florian Wieland
RMRomy Marek
Romy Marek
USUwe Yacine Schwarze
Uwe Yacine Schwarze
Anton DavydokAnton Davydok
Anton Davydok
BZBerit Zeller-Plumhoff
Berit Zeller-Plumhoff
Magnesium alloys are some of the most convenient biodegradable materials for bone fracture treatment due to their tailorable degradation rate, biocompatibility, and mechanical properties resembling those of bone. Despite the fact that magnesium-based implants and ZX00 (Mg-0.45Zn-0.45Ca in wt.%), in particular, have been shown to have suitable degradation rates and good osseointegration, knowledge gaps remain in our understanding of the impact of their degradation properties on the bone’s ultrastructure. Bone is a hierarchically structured material, where not only the microstructure but also the ultrastructure are important as properties like the local mechanical response are determined by it. This study presents the first comparative analysis of bone ultrastructure parameters with high spatial resolution around ZX00 and Ti implants after 6, 12, and 24 weeks of healing. The mineralization was investigated, revealing a significant decrease in the lattice spacing of the (002) Bragg’s peak closer to the ZX00 implant in comparison to Ti, while no significant difference in the crystallite size was observed. The hydroxyapatite platelet thickness and osteon density demonstrated a decrease closer to the ZX00 implant interface. Correlative indentation and strain maps obtained by scanning X-ray diffraction measurements revealed a higher stiffness and faster mechanical adaptation of the bone surrounding Ti implants as compared to the ZX00 ones. Thus, the results suggest the incorporation of Mg2+ ions into the bone ultrastructure, as well as a lower degree of remodeling and stiffness of the bone in the presence of ZX00 implants than Ti.

22 May 2018 in IOP Conference Series: Earth and Environmental Science
Verified
Conference Paper
Open access
PDF file
KIKamila Iskhakova
Kamila Iskhakova
FMFadis F. Murzakhanov
Fadis F. Murzakhanov
GMGeorgy Vladimirovich Mamin
Georgy Vladimirovich Mamin
VPV. Putlyaev
V. Putlyaev
EKE. Klimashina
E. Klimashina
SOS. Orlinskii
S. Orlinskii
Calcium phosphates (CaP) are exploited in many fields of science, including geology, chemistry, biology and medicine due to their abundance in the nature and presence in the living organism. Various analytical and biochemical methods are used for controlling their chemical content, structure, morphology, etc. Unfortunately, magnetic resonance techniques are usually not even considered as necessary tools for CaP inspection. Some aspects of application of the commercially realized electron paramagnetic resonance (EPR) approaches for characterization of CaP powders and ceramics (including the nanosized materails) such as hydroxyapatite and tricalcium phosphates of biogenic and synthetic origins containing intrinsic impurities or intentional dopants are demonstrated. The key features and advantages of the EPR techniques for CaP based materials characterization that could compliment the data obtained with the recognized analytical methods are pointed out.