Douglas Kelley

Douglas Kelley

orcid

Research Focus & Metrics

Academic Career Length

40Years (1987-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 August 2016 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
MMMerry Mani
Merry Mani
MJMathews Jacob
Mathews Jacob
DKDouglas Kelley
Douglas Kelley
VMVincent A. Magnotta
Vincent A. Magnotta

12 October 2010 in Neurology
Verified
Journal Article
Closed access
PDF file
GKG.A. Kerchner
G.A. Kerchner
CHC.P. Hess
C.P. Hess
KHK.E. Hammond-Rosenbluth
K.E. Hammond-Rosenbluth
DXD. Xu
D. Xu
GRG.D. Rabinovici
G.D. Rabinovici
BMB.L. Miller
B.L. Miller
Objectives: In Alzheimer disease (AD), mounting evidence points to a greater role for synaptic loss than neuronal loss. Supporting this notion, multiple postmortem studies have demonstrated that the hippocampal CA1 apical neuropil is one of the earliest sites of pathology, exhibiting tau aggregates and then atrophy before there is substantial loss of the CA1 pyramidal neurons themselves. In this cross-sectional study, we tested whether tissue loss in the CA1 apical neuropil layer can be observed in vivo in patients with mild AD. Methods: We performed ultra-high-field 7-T MRI on subjects with mild AD (n = 14) and age-matched normal controls (n = 16). With a 2-dimensional T2*-weighted gradient-recalled echo sequence that was easily tolerated by subjects, we obtained cross-sectional slices of the hippocampus at an in-plane resolution of 195 μm. Results: On images revealing the anatomic landmarks of hippocampal subfields and strata, we observed thinning of the CA1 apical neuropil in subjects with mild AD compared to controls. By contrast, the 2 groups exhibited no difference in the thickness of the CA1 cell body layer or of the entire CA1 subfield. Hippocampal volume, measured on a conventional T1-weighted sequence obtained at 3T, also did not differentiate these patients with mild AD from controls. Conclusions: CA1 apical neuropil atrophy is apparent in patients with mild AD. With its superior spatial resolution, 7-T MRI permits in vivo analysis of a very focal, early site of AD pathology.

1 June 2008 in Journal of Magnetic Resonance
Verified
Journal Article
Closed access
SHSimon Hu
Simon Hu
MLMichael Lustig
Michael Lustig
ACAlbert P. Chen
Albert P. Chen
JCJason Crane
Jason Crane
AKAdam Kerr
Adam Kerr
DVDaniel B. Vigneron
Daniel B. Vigneron

1 February 2008 in NeuroImage
Verified
Journal Article
Closed access
KHKathryn E. Hammond
Kathryn E. Hammond
JLJanine M. Lupo
Janine M. Lupo
DXDuan Xu
Duan Xu
MMMeredith Metcalf
Meredith Metcalf
DKDouglas Kelley
Douglas Kelley
SNSarah J. Nelson
Sarah J. Nelson

26 September 2005 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
CCCharles H. Cunningham
Charles H. Cunningham
DVDaniel B. Vigneron
Daniel B. Vigneron
ACAlbert P. Chen
Albert P. Chen
DXDuan Xu
Duan Xu
SNSarah J. Nelson
Sarah J. Nelson
JPJohn M. Pauly
John M. Pauly
The spatial resolution of conventional magnetic resonance spectroscopic imaging‐(MRSI) is typically coarse, mainly due to SNR limitations. The increased signal available with higher field scanners and new array coils now permits higher spatial resolution, but conventional chemical shift imaging (phase encoding) limits the spatial coverage possible in a patient‐acceptable acquisition time. The “flyback” echo‐planar trajectory is particularly insensitive to errors and provides data that are simple to process. In this study, high‐efficiency gradient waveforms for flyback echo‐planar MRSI were designed and implemented. Normal volunteer studies at 3 T showed the feasibility of acquiring high spatial resolution with large coverage in a short scan time (2048 voxels in 2.3 min and 4096 voxels in 8.5 min). The trajectories were insensitive to errors in timing and require only a modest (10 to 30%) penalty in SNR relative to conventional phase encoding using the same acquisition time. Magn Reson Med, 2005.

1 September 2009 in Investigative Radiology
Verified
Journal Article
Closed access
RKRoland Krug
Roland Krug
CSChristoph Stehling
Christoph Stehling
DKDouglas Kelley
Douglas Kelley
SMSharmila Majumdar
Sharmila Majumdar
TLThomas M. Link
Thomas M. Link
Recently, great progress has been made in particularly in the imaging of cartilage and bone structure. Increased interest has focused on high-field (3 Tesla) imaging and more recently on ultra-high field (UHF) magnetic resonance imaging (MRI) at 7 T for in vivo imaging. Because the signal-to-noise ratio (SNR) scales linearly with field strength, a substantial increase in SNR is expected compared with lower field strengths. This gain in SNR can be used to increase spatial resolution or reduce imaging time. The goal of this review was to highlight recent developments and challenges in in vivo musculoskeletal (MSK) imaging using UHF-MRI at 7 T. One focus of this review is on the emerging methodology of quantitative MRI for the assessment of trabecular bone structure at the tibia, wrist, and knee. In particular for this application, susceptibility effects between the bone and bone marrow transitions that scale with field strength have to be considered. Another important MSK application is the characterization of knee cartilage morphology. The higher SNR provided by UHF-MRI is a potential advantage for visualizing, segmenting, and analyzing cartilage. Standard clinical MSK imaging relies heavily on T1, T2, and proton density weighted fast spin echo sequences. However, fast spin echo imaging has proven to be very challenging at higher fields because of very high specific absorption rates, using multiple pulses in a short time frame; thus the imaging protocols have to be adapted and gradient echo sequences may be more beneficial. Imaging of more central body parts such as the spine at 7 T is still in its infancy and dedicated coils have to be developed.