This paper studies the design and application of an interferometric sensor system intended for measuring intraocular pressure. The system consists of a hermetically sealed, biocompatible, wireless, and powerless interferometric pressure sensor and a portable handheld reader. The interferometric pressure sensor consists of a 200 nm silicon nitride diaphragm, a $10~\mu \text{m}$ SU-8 spacer, and a $200~\mu \text{m}$ glass substrate. As monochromatic light is directed towards the sensor cavity, interference fringes between the silicon nitride diaphragm and the glass substrate form as a function of the applied pressure. In-vitro measurements show pressure in the range of 0–60 mmHg can be determined reliably with an accuracy of ±0.3 mmHg, while ex-vivo experiments using rabbit cornea showed an accuracy of ±0.6 mmHg. The resolution of the sensor is 0.2 mmHg. These results demonstrate the ability of the system to measure small changes in pressure, including intraocular pressure of glaucoma patients.
24 June 2019 in IEEE Transactions on Biomedical Engineering
Intraocular pressure (IOP) is the leading modifiable risk factor for preventing vision loss in glaucoma patients. Direct and frequent IOP measurements are highly desirable to assess adequacy of treatment and prevent further vision loss. In this study, we report on successful in vivo measurements of intraocular pressure in rabbits using an optical IOP measurement system. The sensor was implanted during cataract surgery in two New Zealand white (NZW) rabbits and tested in vivo for 10 weeks. Prior to implantation, the sensors were characterized in vitro in the physiologically relevant pressure range of 0 mmHg to 60 mmHg. A portable wireless handheld reader consisting of an internal beam splitter, a monochromatic light source, and a digital single-lens reflex (DSLR) camera was also designed and implemented to capture interference patterns from the sensor. The sensitivity and accuracy of the sensor was 30 nm/mmHg and ±0.2 mmHg, respectively. Ten weeks post-implantation, the two New Zealand white rabbits continued to respond well to the implant with no observable inflammation, signs of infection, or biofouling. All IOP measurements were obtained using the portable DSLR handheld reader. Successful in vivo studies demonstrate biocompatibility of the IOP sensor and prove feasibility of the IOP measurement system. The system has the potential to be used in both clinical and patient point-of-care (home) settings to frequently and accurately measure pressure.
We have studied the reliability of a near field transducer (NFT) embedded in a magnetic recording slider used for heat-assisted magnetic recording (HAMR) in hard disk drives with a linear velocity of 20 m/s. The NFT head structure and the disk are separated by an air film of 2 nm thickness. In this work, the magnetic write width and amplitude of the written magnetic signal on the disk are used as a “health-monitor” for the reliability of the NFT under long-term thermal exposure. The results show that the reliability of the NFT head structure decreases sharply with increasing temperature of the near field transducer but depends only slightly on the media temperature.