Phuong Truong

Phuong Truong

Auto-generated profile, based on publicly available information

Phuong Truong

University of California San Diego, La Jolla, CA

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 October 2017 in IEEE Sensors Journal
Verified
Journal Article
Open access
APAlex Phan
Alex Phan
PTPhuong Truong
Phuong Truong
JTJulian Trumpp
Julian Trumpp
FTFrank E. Talke
Frank E. Talke
This paper studies the design and application of an interferometric sensor system intended for measuring intraocular pressure. The system consists of a hermetically sealed, biocompatible, wireless, and powerless interferometric pressure sensor and a portable handheld reader. The interferometric pressure sensor consists of a 200 nm silicon nitride diaphragm, a $10~\mu \text{m}$ SU-8 spacer, and a $200~\mu \text{m}$ glass substrate. As monochromatic light is directed towards the sensor cavity, interference fringes between the silicon nitride diaphragm and the glass substrate form as a function of the applied pressure. In-vitro measurements show pressure in the range of 0–60 mmHg can be determined reliably with an accuracy of ±0.3 mmHg, while ex-vivo experiments using rabbit cornea showed an accuracy of ±0.6 mmHg. The resolution of the sensor is 0.2 mmHg. These results demonstrate the ability of the system to measure small changes in pressure, including intraocular pressure of glaucoma patients.

24 June 2019 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
APAlex Phan
Alex Phan
PTPhuong Truong
Phuong Truong
ACAndrew Camp
Andrew Camp
KSKerrianne Stewart
Kerrianne Stewart
BSBenjamin Suen
Benjamin Suen
FTFrank E. Talke
Frank E. Talke
Intraocular pressure (IOP) is the leading modifiable risk factor for preventing vision loss in glaucoma patients. Direct and frequent IOP measurements are highly desirable to assess adequacy of treatment and prevent further vision loss. In this study, we report on successful in vivo measurements of intraocular pressure in rabbits using an optical IOP measurement system. The sensor was implanted during cataract surgery in two New Zealand white (NZW) rabbits and tested in vivo for 10 weeks. Prior to implantation, the sensors were characterized in vitro in the physiologically relevant pressure range of 0 mmHg to 60 mmHg. A portable wireless handheld reader consisting of an internal beam splitter, a monochromatic light source, and a digital single-lens reflex (DSLR) camera was also designed and implemented to capture interference patterns from the sensor. The sensitivity and accuracy of the sensor was 30 nm/mmHg and ±0.2 mmHg, respectively. Ten weeks post-implantation, the two New Zealand white rabbits continued to respond well to the implant with no observable inflammation, signs of infection, or biofouling. All IOP measurements were obtained using the portable DSLR handheld reader. Successful in vivo studies demonstrate biocompatibility of the IOP sensor and prove feasibility of the IOP measurement system. The system has the potential to be used in both clinical and patient point-of-care (home) settings to frequently and accurately measure pressure.

22 May 2020 in Microsystem Technologies
Verified
Journal Article
Closed access
PDF file
PTPhuong Truong
Phuong Truong
APAlex Phan
Alex Phan
BTBuu Truong
Buu Truong
BSBenjamin Suen
Benjamin Suen
GMGerrit Melles
Gerrit Melles
FTFrank E. Talke
Frank E. Talke

17 April 2024 in IEEE Journal of Translational Engineering in Health and Medicine
Verified
Journal Article
Open access
PTPhuong Truong
Phuong Truong
EWErin Walsh
Erin Walsh
VSVanessa P. Scott
Vanessa P. Scott
MLMichelle Leff
Michelle Leff
ACAlice Chen
Alice Chen
JFJames Friend
James Friend
Objective: Identify infants with abnormal suckling behavior from simple non-nutritive suckling devices.Background: While it is well known breastfeeding is beneficial to the health of both mothers and infants, breastfeeding ceases in 75 percent of mother-child dyads by 6 months. The current standard of care lacks objective measurements to screen infant suckling abnormalities within the first few days of life, a critical time to establish milk supply and successful breastfeeding practices.Materials and Methods: A non-nutritive suckling vacuum measurement system, previously developed by the authors, is used to gather data from 91 healthy full-term infants under thirty days old. Non-nutritive suckling was recorded for a duration of sixty seconds. We establish normative data for the mean suck vacuum, maximum suck vacuum, suckling frequency, burst duration, sucks per burst, and vacuum signal shape. We then apply computational methods (Mahalanobis distance, KNN) to detect anomalies in the data to identify infants with abnormal suckling. We finally provide case studies of healthy newborn infants and infants diagnosed with ankyloglossia.Results: In a series of case evaluations, we demonstrate the ability to detect abnormal suckling behavior using statistical analysis and machine learning. We evaluate cases of ankyloglossia to determine how oral dysfunction and surgical interventions affect non-nutritive suckling measurements.Conclusions: Statistical analysis (Mahalanobis Distance) and machine learning [K nearest neighbor (KNN)] can be viable approaches to rapidly interpret infant suckling measurements. Particularly in practices using the digital suck assessment with a gloved finger, it can provide a more objective, early stage screening method to identify abnormal infant suckling vacuum. This approach for identifying those at risk for breastfeeding complications is crucial to complement complex emerging clinical evaluation technology.Clinical Impact: By analyzing non-nutritive suckling using computational methods, we demonstrate the ability to detect abnormal and normal behavior in infant suckling that can inform breastfeeding intervention pathways in clinic.Clinical and Translational Impact Statement: The work serves to shed light on the lack of consensus for determining appropriate intervention pathways for infant oral dysfunction. We demonstrate using statistical analysis and machine learning that normal and abnormal infant suckling can be identified and used in determining if surgical intervention is a necessary solution to resolve infant feeding difficulties.

1 November 2017
Verified
Conference Paper
Closed access
APAlex Phan
Alex Phan
PTPhuong Truong
Phuong Truong
AKAlexander Kief
Alexander Kief
MDMilien Dhome
Milien Dhome
ACAndrew Camp
Andrew Camp
FTFrank E. Talke
Frank E. Talke
This paper reports on ex-vivo studies with rabbit eyes using an optical intraocular pressure (IOP) measurement system. The system consists of an optical reader and a miniaturized interferometric pressure sensor integrated onto a standard intraocular lens. The results show that the measurement sensitivity of the sensor is on the order of 22 nm/mmHg with an accuracy of ±0.5 mmHg post implantation. The optical method developed is a promising approach for monitoring intraocular pressure for glaucoma patients. The portability of the measurement system may allow patients and physicians to conveniently obtain measurements in a patient point-of-care setting or a clinical environment.

24 June 2020
Verified
Conference Paper
Closed access
PDF file
CSChristoph Schade
Christoph Schade
APAlex Phan
Alex Phan
KJKevin Joslin
Kevin Joslin
PTPhuong Truong
Phuong Truong
FTFrank E. Talke
Frank E. Talke
The time dependent dissolution of silicon nitride is studied in a simulated eye environment (controlled saline solution) as a function of temperature and pressure. Silicon nitride films manufactured by plasma-enhanced chemical vapor deposition (PECVD) and low-pressure chemical vapor deposition (LPCVD), respectively, were tested. The results revealed that both film types showed evidence of dissolution i.e., the films dissolved in the saline solution over time. At 37°C, PECVD and LPCVD silicon nitride membranes dissolved at a rate of 1.3 nm/day and 0.3 nm/day, respectively. It was found that at 23°C, the dissolution rate of the PECVD samples reduced to just 0.2 nm/day. Dissolution was not observed in samples tested in deionized water at 37°C. Titanium oxide layers (TiO2) were tested as protective layers to stop the dissolution. The results are important for implantable MEMS devices where silicon nitride is used as a functional membrane or as a protective layer.