Yuta Koshino

Dr. Yuta Koshino

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 November 2022 in Archives of Physical Medicine and Rehabilitation
Verified
Journal Article
Closed access
YKYuta Koshino
Yuta Koshino
TKTakumi Kobayashi
Takumi Kobayashi

13 December 2023 in Sensors
Verified
Journal Article
Open access
PDF file
TITakumi Ino
Takumi Ino
MSMina Samukawa
Mina Samukawa
TITomoya Ishida
Tomoya Ishida
NWNaofumi Wada
Naofumi Wada
YKYuta Koshino
Yuta Koshino
HTHarukazu Tohyama
Harukazu Tohyama
Accuracy validation of gait analysis using pose estimation with artificial intelligence (AI) remains inadequate, particularly in objective assessments of absolute error and similarity of waveform patterns. This study aimed to clarify objective measures for absolute error and waveform pattern similarity in gait analysis using pose estimation AI (OpenPose). Additionally, we investigated the feasibility of simultaneous measuring both lower limbs using a single camera from one side. We compared motion analysis data from pose estimation AI using video footage that was synchronized with a three-dimensional motion analysis device. The comparisons involved mean absolute error (MAE) and the coefficient of multiple correlation (CMC) to compare the waveform pattern similarity. The MAE ranged from 2.3 to 3.1° on the camera side and from 3.1 to 4.1° on the opposite side, with slightly higher accuracy on the camera side. Moreover, the CMC ranged from 0.936 to 0.994 on the camera side and from 0.890 to 0.988 on the opposite side, indicating a “very good to excellent” waveform similarity. Gait analysis using a single camera revealed that the precision on both sides was sufficiently robust for clinical evaluation, while measurement accuracy was slightly superior on the camera side.

9 September 2024 in Journal of Sports Science and Medicine
Verified
Journal Article
Open access
PDF file
TITakumi Ino
Takumi Ino
MSMina Samukawa
Mina Samukawa
TITomoya Ishida
Tomoya Ishida
NWNaofumi Wada
Naofumi Wada
YKYuta Koshino
Yuta Koshino
HTHarukazu Tohyama
Harukazu Tohyama
OpenPose-based motion analysis (OpenPose-MA), utilizing deep learning methods, has emerged as a compelling technique for estimating human motion. It addresses the drawbacks associated with conventional three-dimensional motion analysis (3D-MA) and human visual detection-based motion analysis (Human-MA), including costly equipment, time-consuming analysis, and restricted experimental settings. This study aims to assess the precision of OpenPose-MA in comparison to Human-MA, using 3D-MA as the reference standard. The study involved a cohort of 21 young and healthy adults. OpenPose-MA employed the OpenPose algorithm, a deep learning-based open-source two-dimensional (2D) pose estimation method. Human-MA was conducted by a skilled physiotherapist. The knee valgus angle during a drop vertical jump task was computed by OpenPose-MA and Human-MA using the same frontal-plane video image, with 3D-MA serving as the reference standard. Various metrics were utilized to assess the reproducibility, accuracy and similarity of the knee valgus angle between the different methods, including the intraclass correlation coefficient (ICC) (1, 3), mean absolute error (MAE), coefficient of multiple correlation (CMC) for waveform pattern similarity, and Pearson’s correlation coefficients (OpenPose-MA vs. 3D-MA, Human-MA vs. 3D-MA). Unpaired t-tests were conducted to compare MAEs and CMCs between OpenPose-MA and Human-MA. The ICCs (1,3) for OpenPose-MA, Human-MA, and 3D-MA demonstrated excellent reproducibility in the DVJ trial. No significant difference between OpenPose-MA and Human-MA was observed in terms of the MAEs (OpenPose: 2.4° [95%CI: 1.9-3.0°], Human: 3.2° [95%CI: 2.1-4.4°]) or CMCs (OpenPose: 0.83 [range: 0.99-0.53], Human: 0.87 [range: 0.24-0.98]) of knee valgus angles. The Pearson’s correlation coefficients of OpenPose-MA and Human-MA relative to that of 3D-MA were 0.97 and 0.98, respectively. This study demonstrated that OpenPose-MA achieved satisfactory reproducibility, accuracy and exhibited waveform similarity comparable to 3D-MA, similar to Human-MA. Both OpenPose-MA and Human-MA showed a strong correlation with 3D-MA in terms of knee valgus angle excursion.

26 February 2023 in Physical Therapy in Sport
Verified
Journal Article
Closed access
KWKentaro Watanabe
Kentaro Watanabe
YKYuta Koshino
Yuta Koshino
DKDaiki Kawahara
Daiki Kawahara
MAMoeko Akimoto
Moeko Akimoto
MMMasumi Mishina
Masumi Mishina
HTHarukazu Tohyama
Harukazu Tohyama

16 January 2019 in Journal of Orthopaedic Research
Verified
Journal Article
Closed access
PDF file
TOTakumi Okunuki
Takumi Okunuki
YKYuta Koshino
Yuta Koshino
MYMasanori Yamanaka
Masanori Yamanaka
KTKaori Tsutsumi
Kaori Tsutsumi
MIMasato Igarashi
Masato Igarashi
HTHarukazu Tohyama
Harukazu Tohyama

15 June 2022 in International Orthopaedics
Verified
Journal Article
Closed access
PDF file
YKYuta Koshino
Yuta Koshino
STShohei Taniguchi
Shohei Taniguchi
TKTakumi Kobayashi
Takumi Kobayashi
MSMina Samukawa
Mina Samukawa
MIMasayuki Inoue
Masayuki Inoue