Naofumi Wada

Prof. Dr. Naofumi Wada


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 December 2023 in Sensors
Verified
Journal Article
Open access
PDF file
TITakumi Ino
Takumi Ino
MSMina Samukawa
Mina Samukawa
TITomoya Ishida
Tomoya Ishida
NWNaofumi Wada
Naofumi Wada
YKYuta Koshino
Yuta Koshino
HTHarukazu Tohyama
Harukazu Tohyama
Accuracy validation of gait analysis using pose estimation with artificial intelligence (AI) remains inadequate, particularly in objective assessments of absolute error and similarity of waveform patterns. This study aimed to clarify objective measures for absolute error and waveform pattern similarity in gait analysis using pose estimation AI (OpenPose). Additionally, we investigated the feasibility of simultaneous measuring both lower limbs using a single camera from one side. We compared motion analysis data from pose estimation AI using video footage that was synchronized with a three-dimensional motion analysis device. The comparisons involved mean absolute error (MAE) and the coefficient of multiple correlation (CMC) to compare the waveform pattern similarity. The MAE ranged from 2.3 to 3.1° on the camera side and from 3.1 to 4.1° on the opposite side, with slightly higher accuracy on the camera side. Moreover, the CMC ranged from 0.936 to 0.994 on the camera side and from 0.890 to 0.988 on the opposite side, indicating a “very good to excellent” waveform similarity. Gait analysis using a single camera revealed that the precision on both sides was sufficiently robust for clinical evaluation, while measurement accuracy was slightly superior on the camera side.

9 September 2024 in Journal of Sports Science and Medicine
Verified
Journal Article
Open access
PDF file
TITakumi Ino
Takumi Ino
MSMina Samukawa
Mina Samukawa
TITomoya Ishida
Tomoya Ishida
NWNaofumi Wada
Naofumi Wada
YKYuta Koshino
Yuta Koshino
HTHarukazu Tohyama
Harukazu Tohyama
OpenPose-based motion analysis (OpenPose-MA), utilizing deep learning methods, has emerged as a compelling technique for estimating human motion. It addresses the drawbacks associated with conventional three-dimensional motion analysis (3D-MA) and human visual detection-based motion analysis (Human-MA), including costly equipment, time-consuming analysis, and restricted experimental settings. This study aims to assess the precision of OpenPose-MA in comparison to Human-MA, using 3D-MA as the reference standard. The study involved a cohort of 21 young and healthy adults. OpenPose-MA employed the OpenPose algorithm, a deep learning-based open-source two-dimensional (2D) pose estimation method. Human-MA was conducted by a skilled physiotherapist. The knee valgus angle during a drop vertical jump task was computed by OpenPose-MA and Human-MA using the same frontal-plane video image, with 3D-MA serving as the reference standard. Various metrics were utilized to assess the reproducibility, accuracy and similarity of the knee valgus angle between the different methods, including the intraclass correlation coefficient (ICC) (1, 3), mean absolute error (MAE), coefficient of multiple correlation (CMC) for waveform pattern similarity, and Pearson’s correlation coefficients (OpenPose-MA vs. 3D-MA, Human-MA vs. 3D-MA). Unpaired t-tests were conducted to compare MAEs and CMCs between OpenPose-MA and Human-MA. The ICCs (1,3) for OpenPose-MA, Human-MA, and 3D-MA demonstrated excellent reproducibility in the DVJ trial. No significant difference between OpenPose-MA and Human-MA was observed in terms of the MAEs (OpenPose: 2.4° [95%CI: 1.9-3.0°], Human: 3.2° [95%CI: 2.1-4.4°]) or CMCs (OpenPose: 0.83 [range: 0.99-0.53], Human: 0.87 [range: 0.24-0.98]) of knee valgus angles. The Pearson’s correlation coefficients of OpenPose-MA and Human-MA relative to that of 3D-MA were 0.97 and 0.98, respectively. This study demonstrated that OpenPose-MA achieved satisfactory reproducibility, accuracy and exhibited waveform similarity comparable to 3D-MA, similar to Human-MA. Both OpenPose-MA and Human-MA showed a strong correlation with 3D-MA in terms of knee valgus angle excursion.

11 June 2025 in Sensors
Verified
Journal Article
Open access
PDF file
HTHidenori Takauji
Hidenori Takauji
NWNaofumi Wada
Naofumi Wada
SKShun'ichi Kaneko
Shun'ichi Kaneko
TTTakanari Tanabata
Takanari Tanabata
This paper presents a novel method, Histogram of Angles in Linked Features (HALF), designed for the segmentation of 3D point cloud data of plants for robust sensing. The proposed method leverages local angular features extracted from 3D measurements obtained via sensing technologies such as laser scanning, LiDAR, or photogrammetry. HALF enables efficient identification of plant structures—leaves, stems, and knots—without requiring large-scale labeled datasets, making it highly suitable for applications in plant phenotyping and structural analysis. To enhance robustness and interpretability, we extend HALF to a convolution-based mathematical framework and introduce the Sequential Competitive Segmentation Algorithm (SCSA) for phytomer-level classification. Experimental results using 3D point cloud data of soybean plants demonstrate the feasibility of our method in sensor-based plant monitoring systems. By providing a low-cost and efficient approach for plant structure analysis, HALF contributes to the advancement of sensor-driven plant phenotyping and precision agriculture.