This paper compares the performance of different control techniques applied to a high-performance brushless DC (BLDC) motor. The first controller is a classical proportional integral (PI) controller. In contrast, the second one is based on adaptive neuro-fuzzy inference systems (proportional integral-adaptive neuro-fuzzy inference system (PI-ANFIS) and particle swarm optimization-proportional integral-adaptive neuro-fuzzy inference system (PSO-PI-ANFIS)). The control objective is to regulate the rotor speed to its desired reference value in the presence of load torque disturbance and parameter variations. The proposed controller uses a dSPACE platform (MicroLabBox controller board). The experimental prototype comprises a PEMFC system (the Nexa Ballard FC power generator: 1.2 kW, 52 A) and a brushless DC motor BLDC of 1 kW 1000 rpm. The PSO-PI-ANFIS controller presents better performance than the PI-ANFIS and classical PI controllers due to its ability to optimize the PI-ANFIS controller’s parameters using the particle swarm optimization (PSO) algorithm. This optimization results in improved tracking accuracy and reduced overshoot and settling time.
23 July 2020 in Mathematical Problems in Engineering
The proposed work presented in this paper is mainly focused on the control of the active and reactive stator powers generated by a wind energy conversion system (WECS) based on the dual feed induction generator (DFIG). This control is achieved by acting on the rotor side converter (RSC) to extract the maximum power from the wind turbine (WT) while regulating the rotor currents. Furthermore, another control objective is achieved by acting on the grid side converter (GSC), in which the DC bus voltage is maintained constant and a unity power factor is ensured. To do that, a new robust control known as active disturbance rejection control (ADRC) has been proposed and applied to the WECS. This control is based on the extended state observer (ESO), which is the main core of this algorithm; it makes the estimation and cancellation of the total effect of various uncertainties (internal and external disturbances) possible in real time. To validate the effectiveness of the proposed approach, the system was modeled and simulated by using the Matlab/Simulink software. Two tests, namely, tracking and robustness tests, were performed to compare the proposed ADRC technique and classical PI controllers. The obtained results are promising and have shown that the proposed control strategy based on ADRC, especially when varying the mode parameters, is performant and very useful.
30 March 2023 in Archives of Electrical Engineering
This paper presents a comparative study between the conventional PI (Proportional Integral) and backstepping controllers applied to the DFIG (Doubly Fed Induction Generator) used in WECS (Wind Energy Conversion System). These two different control strategies proposed in this work are developed to control the active and reactive power of the DFIG on the one hand, and to maintain the DC-link voltage constant for the inverting function on the other hand. This is ensured by generating control signals for two power electronic converters, RSC (Rotor Side Converter) and GSC (Grid Side Converter). In order to optimise the power production in the WT (Wind Turbine), an MPPT (Maximum Power Point Tracking) algorithm is applied along with each control technique. To simulate the effectiveness of the proposed controllers, MATLAB/Simulink Software is used, and the obtained results are analysed and discussed to compare PI and backstepping controllers in terms of robustness against wind speed variations and tracking performance in dynamic and steady states.
1 June 2022 in Bulletin of Electrical Engineering and Informatics
This work presents the control of the double fed induction generator (DFIG) used in the wind conversion system (WCS). The studied model is based on the control of the two converters grid side converter (GSC) and rotor side converter (RSC), in order to extract the maximum of power and also to keep the direct current (DC) bus voltage constant. The control strategy used here is based on linear active disturbance rejection control (LADRC) controllers. These are known, in the field of control systems, by their performance and robustness and allow a very good rejection of disturbances which can affect the wind system. In addition, this kind of controllers could help to meet the requirements of robustness against the variations of the parameters of the system and the uncertainties of its mathematical model. To validate the effectiveness of the proposed control, the system was modeled and tested by numerical simulation using MATLAB/Simulink software. The results carried out are discussed and analyzed in terms of references tracking, robustness and disturbance rejection. The results obtained have shown shown that the proposed control is promising and useful.
1 October 2024 in Bulletin of Electrical Engineering and Informatics
This paper introduces a robust and inhanced version of dual control approach based on sequence decomposition loops in order to limit transient over-currents and improving the wind turbine’s operation during asymmetrical voltage dips faults. Indeed, the doubly fed induction generator (DFIG), employed in wind energy conversion system (WECS) to produce electrical energy from wind, highly susceptible to voltage drops, which can cause transient overcurrents in both the stator and the rotor. Without any protection system, these over-currents might damage the DFIG and its converters. The strategy put forward in this work minimizes the consequences of voltage dips on wind system functioning, such as electromagnetic torque fluctuations and it enables wind turbines to maintain electrical connection with the grid in the occurrence of such disturbances. The carried-out results are promising and showed that the proposed control method can effectively minimise the oscillations in electromagnetic torque, reactive power and DC bus voltage during the asymmetrical voltage dip. This analysis also demonstrated its ability to limit the transient over-currents of the DFIG.
1 March 2025 in International Journal of Applied Power Engineering (IJAPE)
In this paper we present two techniques for protecting the doubly fed induction generator (DFIG) in the event of external disturbances on the electrical network, the crowbar circuit and series dynamic braking resistor (SDBR) techniques. During voltage dips, the first technique is triggered and short-circuits the rotor side converter (RSC) so as to maintain the rotor current within the desired limits. As a result, the DFIG behaves as an asynchronous cage generator that absorbs the reactive power coming from the voltage dip on the network which does not meet the grid code's (GC) requirements. The second technique makes it possible to limit overcurrent’s at the level of the stator and rotor of the DFIG, it will enable the wind power system to continue operating normally once the fault has disappeared and to stay connected to the network throughout the voltage dip. This SDBR technique presents a good compromise between its performance, its simplicity, its efficiency, and its implementation’s cost.