John LaDisa

Dr. John LaDisa

orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2012 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
TGTimothy J. Gundert
Timothy J. Gundert
AMAlison L. Marsden
Alison L. Marsden
WYWeiguang Yang
Weiguang Yang
JLJohn LaDisa
John LaDisa
Coronary stent design affects the spatial distribution of wall shear stress (WSS), which can influence the progression of endothelialization, neointimal hyperplasia, and restenosis. Previous computational fluid dynamics (CFD) studies have only examined a small number of possible geometries to identify stent designs that reduce alterations in near-wall hemodynamics. Based on a previously described framework for optimizing cardiovascular geometries, we developed a methodology that couples CFD and three-dimensional shape-optimization for use in stent design. The optimization procedure was fully-automated, such that solid model construction, anisotropic mesh generation, CFD simulation, and WSS quantification did not require user intervention. We applied the method to determine the optimal number of circumferentially repeating stent cells (NC) for slotted-tube stents with various diameters and intrastrut areas. Optimal stent designs were defined as those minimizing the area of low intrastrut time-averaged WSS. Interestingly, we determined that the optimal value of NC was dependent on the intrastrut angle with respect to the primary flow direction. Further investigation indicated that stent designs with an intrastrut angle of approximately 40 deg minimized the area of low time-averaged WSS regardless of vessel size or intrastrut area. Future application of this optimization method to commercially available stent designs may lead to stents with superior hemodynamic performance and the potential for improved clinical outcomes.

31 July 2011 in Congenital Heart Disease
Verified
Journal Article
Closed access
PDF file
JLJohn LaDisa
John LaDisa
RDRonak J. Dholakia
Ronak J. Dholakia
C. Alberto FigueroaC. Alberto Figueroa
C. Alberto Figueroa
IVIrene E. Vignon-Clementel
Irene E. Vignon-Clementel
FCFrandics P. Chan
Frandics P. Chan
JFJeffrey A. Feinstein
Jeffrey A. Feinstein
Background. Atherosclerotic plaque in the descending thoracic aorta (dAo) is related to altered wall shear stress (WSS) for normal patients. Resection with end‐to‐end anastomosis (RWEA) is the gold standard for coarctation of the aorta (CoA) repair, but may lead to altered WSS indices that contribute to morbidity. Methods. Computational fluid dynamics (CFD) models were created from imaging and blood pressure data for control subjects and age‐ and gender‐matched CoA patients treated by RWEA (four males, two females, 15 ± 8 years). CFD analysis incorporated downstream vascular resistance and compliance to generate blood flow velocity, time‐averaged WSS (TAWSS), and oscillatory shear index (OSI) results. These indices were quantified longitudinally and circumferentially in the dAo, and several visualization methods were used to highlight regions of potential hemodynamic susceptibility. Results. The total dAo area exposed to subnormal TAWSS and OSI was similar between groups, but several statistically significant local differences were revealed. Control subjects experienced left‐handed rotating patterns of TAWSS and OSI down the dAo. TAWSS was elevated in CoA patients near the site of residual narrowings and OSI was elevated distally, particularly along the left dAo wall. Differences in WSS indices between groups were negligible more than 5 dAo diameters distal to the aortic arch. Conclusions. Localized differences in WSS indices within the dAo of CoA patients treated by RWEA suggest that plaque may form in unique locations influenced by the surgical repair. These regions can be visualized in familiar and intuitive ways allowing clinicians to track their contribution to morbidity in longitudinal studies.

1 July 2016 in Journal of Biomechanics
Verified
Journal Article
Closed access
CCClaudio Chiastra
Claudio Chiastra
WWWei Wu
Wei Wu
BDBenjamin Dickerhoff
Benjamin Dickerhoff
AAAli Aleiou
Ali Aleiou
GDGabriele Dubini
Gabriele Dubini
JLJohn LaDisa
John LaDisa

4 January 2011 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
TGTimothy J. Gundert
Timothy J. Gundert
SSShawn C. Shadden
Shawn C. Shadden
AWAndrew R. Williams
Andrew R. Williams
BKBon-Kwon Koo
Bon-Kwon Koo
JFJeffrey A. Feinstein
Jeffrey A. Feinstein
JLJohn LaDisa
John LaDisa

20 August 2012 in Medical Engineering & Physics
Verified
Journal Article
Closed access
DWDavid C. Wendell
David C. Wendell
MSMargaret M. Samyn
Margaret M. Samyn
JCJoseph R. Cava
Joseph R. Cava
LELaura M. Ellwein
Laura M. Ellwein
MKMary M. Krolikowski
Mary M. Krolikowski
JLJohn LaDisa
John LaDisa
Computational fluid dynamics (CFD) simulations quantifying thoracic aortic flow patterns have not included disturbances from the aortic valve (AoV). 80% of patients with aortic coarctation (CoA) have a bicuspid aortic valve (BAV) which may cause adverse flow patterns contributing to morbidity. Our objectives were to develop a method to account for the AoV in CFD simulations, and quantify its impact on local hemodynamics. The method developed facilitates segmentation of the AoV, spatiotemporal interpolation of segments, and anatomic positioning of segments at the CFD model inlet. The AoV was included in CFD model examples of a normal (tricuspid AoV) and a post-surgical CoA patient (BAV). Velocity, turbulent kinetic energy (TKE), time-averaged wall shear stress (TAWSS), and oscillatory shear index (OSI) results were compared to equivalent simulations using a plug inlet profile. The plug inlet greatly underestimated TKE for both examples. TAWSS differences extended throughout the thoracic aorta for the CoA BAV, but were limited to the arch for the normal example. OSI differences existed mainly in the ascending aorta for both cases. The impact of AoV can now be included with CFD simulations to identify regions of deleterious hemodynamics thereby advancing simulations of the thoracic aorta one step closer to reality.

21 November 2013 in Pediatric Cardiology
Verified
Journal Article
Closed access
PDF file
SKSung Kwon
Sung Kwon
JFJeffrey A. Feinstein
Jeffrey A. Feinstein
RDRonak J. Dholakia
Ronak J. Dholakia
JLJohn LaDisa
John LaDisa