Claudio Chiastra

Dr. Claudio Chiastra

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 July 2013 in Journal of The Royal Society Interface
Verified
Journal Article
Open access
PDF file
CCClaudio Chiastra
Claudio Chiastra
SMStefano Morlacchi
Stefano Morlacchi
DGDiego Gallo
Diego Gallo
Umberto MorbiducciUmberto Morbiducci
Umberto Morbiducci
RCRubén Cárdenes
Rubén Cárdenes
FMFrancesco Migliavacca
Francesco Migliavacca
One of the relevant phenomenon associated with in-stent restenosis in coronary arteries is an altered haemodynamics in the stented region. Computational fluid dynamics (CFD) offers the possibility to investigate the haemodynamics at a level of detail not always accessible within experimental techniques. CFD can quantify and correlate the local haemodynamics structures which might lead to in-stent restenosis. The aim of this work is to study the fluid dynamics of realistic stented coronary artery models which replicate the complete clinical procedure of stent implantation. Two cases of pathologic left anterior descending coronary arteries with their bifurcations are reconstructed from computed tomography angiography and conventional coronary angiography images. Results of wall shear stress and relative residence time show that the wall regions more prone to the risk of restenosis are located next to stent struts, to the bifurcations and to the stent overlapping zone for both investigated cases. Considering a bulk flow analysis, helical flow structures are generated by the curvature of the zone upstream from the stent and by the bifurcation regions. Helical recirculating microstructures are also visible downstream from the stent struts. This study demonstrates the feasibility to virtually investigate the haemodynamics of patient-specific coronary bifurcation geometries.

22 August 2019 in Cardiovascular Research
Verified
Journal Article
Open access
PDF file
AHAyla Hoogendoorn
Ayla Hoogendoorn
AKAnnette M Kok
Annette M Kok
EHEline M J Hartman
Eline M J Hartman
GNGiuseppe De Nisco
Giuseppe De Nisco
LCLorena Casadonte
Lorena Casadonte
JWJolanda J Wentzel
Jolanda J Wentzel
Atherosclerotic plaque development has been associated with wall shear stress (WSS). However, the multidirectionality of blood flow, and thus of WSS, is rarely taken into account. The purpose of this study was to comprehensively compare five metrics that describe (multidirectional) WSS behaviour and assess how WSS multidirectionality affects coronary plaque initiation and progression. Adult familial hypercholesterolaemic pigs (n = 10) that were fed a high-fat diet, underwent imaging of the three main coronary arteries at three-time points [3 (T1), 9 (T2), and 10–12 (T3) months]. Three-dimensional geometry of the arterial lumen, in combination with local flow velocity measurements, was used to calculate WSS at T1 and T2. For analysis, arteries were divided into 3 mm/45° sectors (n = 3648). Changes in wall thickness and final plaque composition were assessed with near-infrared spectroscopy–intravascular ultrasound, optical coherence tomography imaging, and histology. Both in pigs with advanced and mild disease, the highest plaque progression rate was exclusively found at low time-averaged WSS (TAWSS) or high multidirectional WSS regions at both T1 and T2. However, the eventually largest plaque growth was located in regions with initial low TAWSS or high multidirectional WSS that, over time, became exposed to high TAWSS or low multidirectional WSS at T2. Besides plaque size, also the presence of vulnerable plaque components at the last time point was related to low and multidirectional WSS. Almost all WSS metrics had good predictive values for the development of plaque (47–50%) and advanced fibrous cap atheroma (FCA) development (59–61%). This study demonstrates that low and multidirectional WSS promote both initiation and progression of coronary atherosclerotic plaques. The high-predictive values of the multidirectional WSS metrics for FCA development indicate their potential as an additional clinical marker for the vulnerable disease.

19 February 2013 in Medical Engineering & Physics
Verified
Journal Article
Closed access
SMStefano Morlacchi
Stefano Morlacchi
SCSebastian George Colleoni
Sebastian George Colleoni
RCRubén Cárdenes
Rubén Cárdenes
CCClaudio Chiastra
Claudio Chiastra
JDJose Luis Diez
Jose Luis Diez
FMFrancesco Migliavacca
Francesco Migliavacca
Computational simulations of stenting procedures in idealized geometries can only provide general guidelines and their use in the patient-specific planning of percutaneous treatments is inadequate. Conversely, image-based patient-specific tools that are able to realistically simulate different interventional options might facilitate clinical decision-making and provide useful insights on the treatment for each individual patient. The aim of this work is the implementation of a patient-specific model that uses image-based reconstructions of coronary bifurcations and is able to replicate real stenting procedures following clinical indications. Two clinical cases are investigated focusing the attention on the open problems of coronary bifurcations and their main treatment, the provisional side branch approach. Image-based reconstructions are created combining the information from conventional coronary angiography and computed tomography angiography while structural finite element models are implemented to replicate the real procedure performed in the patients. First, numerical results show the biomechanical influence of stents deployment in the coronary bifurcations during and after the procedures. In particular, the straightening of the arterial wall and the influence of two overlapping stents on stress fields are investigated here. Results show that a sensible decrease of the vessel tortuosity occurs after stent implantation and that overlapping devices result in an increased stress state of both the artery and the stents. Lastly, the comparison between numerical and image-based post-stenting configurations proved the reliability of such models while replicating stent deployment in coronary arteries.

1 August 2015 in JACC: Cardiovascular Interventions
Verified
Journal Article
Closed access
AAAntonios P. Antoniadis
Antonios P. Antoniadis
PMPeter Mortier
Peter Mortier
GKGhassan Kassab
Ghassan Kassab
GDGabriele Dubini
Gabriele Dubini
NFNicolas Foin
Nicolas Foin
YCYiannis S. Chatzizisis
Yiannis S. Chatzizisis

28 November 2018 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
GNGiuseppe De Nisco
Giuseppe De Nisco
AKAnnette M. Kok
Annette M. Kok
CCClaudio Chiastra
Claudio Chiastra
DGDiego Gallo
Diego Gallo
AHAyla Hoogendoorn
Ayla Hoogendoorn
Umberto MorbiducciUmberto Morbiducci
Umberto Morbiducci

1 July 2016 in Journal of Biomechanics
Verified
Journal Article
Closed access
CCClaudio Chiastra
Claudio Chiastra
WWWei Wu
Wei Wu
BDBenjamin Dickerhoff
Benjamin Dickerhoff
AAAli Aleiou
Ali Aleiou
GDGabriele Dubini
Gabriele Dubini
JLJohn LaDisa
John LaDisa