Restoring motor function in individuals with spinal cord injuries (SCIs), strokes, or amputations is a crucial challenge. Recent studies show that spared motor neurons can still be voluntarily controlled using surface electromyography (EMG), even without visible movement. To harness these signals, we developed a wireless, high-density EMG bracelet and a software framework, MyoGestic. Our system enables rapid adaptation of machine learning models to users’ needs, allowing real-time decoding of spared motor dimensions. In our study, we successfully decoded motor intent from two participants with traumatic SCI, two with spinal stroke, and three with amputations in real time, achieving multiple controllable motor dimensions within minutes. The decoded neural signals could control a digitally rendered hand, an orthosis, a prosthesis, or a two-dimensional cursor. MyoGestic’s participant-centered approach allows a collaborative and iterative development of myocontrol algorithms, bridging the gap between researcher and participant, to advance intuitive EMG interfaces for neural lesions.
16 March 2022 in IEEE Robotics and Automation Letters
This letter presents a highly dynamic cable-driven robotic wrist with two degrees of freedom (DOFs). It is based on a novel topology that combines three passive cables for kinematic constraint and the minimal number of active cables for the full control of a movable platform in two rotational DOFs. For a certain geometry of the wrist, the workspace is analyzed using the structure matrix. To control the motion of the wrist, the use of an inertial measurement unit is proposed to directly estimate the orientation and angular velocity, contrarily to the majority of previous cable-driven mechanisms whose control relies on the forward kinematics. Based on the measured data, a standard cascaded controller calculates target torques about two fixed axes of rotation, which are converted into target tensions for the three active cables by the existing closed-form solution. The proposed concept is validated with a hardware prototype. A quasi-static experiment shows that the wrist covers a workspace of up to $\pm 55^{\circ }$ about both rotation axes. Highly dynamic rotations are demonstrated by step responses with an angular velocity of up to 700 $^{\circ }$ /s.
The load-adaptive behavior of the muscles in the human musculoskeletal system offers great potential for minimizing resource and energy requirements in many technical systems, especially in drive technology and robotics. However, the lack of knowledge about suitable technical linear actuators that can reproduce the load-adaptive behavior of biological muscles in technology is a major reason for the lack of successful implementation of this biological principle. In this paper, therefore, the different types of linear actuators are investigated. The focus is particularly on artificial muscles and rope pulls. The study is based on literature, on the one hand, and on two physical demonstrators in the form of articulated robots, on the other hand. The studies show that ropes are currently the best way to imitate the load-adaptive behavior of the biological model in technology. This is especially illustrated in the context of this paper by the discussion of different advantages and disadvantages of the technical linear actuators, where ropes, among other things, have a good mechanical and control behavior, which is very advantageous for use in an adaptive system. Finally, the next steps for future research are outlined to conclude how ropes can be used as linear actuators to transfer load-adaptive lightweight design into technical applications.
The treatment of stress urinary incontinence (SUI) is a socioeconomic and medical as well as technological challenge. Current artificial urinary sphincters (AUS) require invasive surgery, have high complication rates, are not sex independent, or are technically immature. This publication presents an improved version of a minimally invasive, mechatronic intraurethral sphincter prosthesis. It uses a new actuator design based on elastomer compression, a new assembly process, and silicone overmolding to improve functionality, reliability, biocompatibility, and manufacturability. The new design increases the flow channel area by more than 175%, reduces the required actuation stroke by 33%, and achieves easier assembly and complete hermetic sealing of the components. The new design lays the foundation for further research, not only for intraurethral sphincter prostheses, but also for pinch valves in general, which have a large ratio of flow area to build volume and low energy consumption.